• 제목/요약/키워드: External noise

검색결과 673건 처리시간 0.031초

Design and Evaluation of Noise Suppressing Hydrophone

  • Im, Jong-in
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2000년도 International Symposium on Magnetics The 2000 Fall Conference
    • /
    • pp.546-560
    • /
    • 2000
  • This paper describes the design and evaluation of a noise suppressing hydrophone that is robust to external noise without sacrificing its performance as a receiver. To increase robustness of the receiver to the external noise, first, effects of location of external noise on its performance are analyzed with the finite element method (FEM). Based on the results, geometrical variations are implemented on the structure with additional air pockets and damping layers that work as acoustic shields or scatterers of the noise, and fourteen trial models are developed for the noise suppressing hydrophone structures. The results show that the effect of the external noise is most significant when it is applied to near the mid-side surface of the hydrophone housing. The external noise is isolated most efficiently when two thin damping layers combined with five air pockets are inserted to the circumference of the hydrophone housing. Overall, of the fourteen structural variations of the hydrophone, the best one shows about 87% reduction in the response of the original structure to external noise.

  • PDF

스테레오비전시스템을 이용한 실내 영상감시시스템의 외란광 간섭 경감에 관한 연구 (A Study on External Light Noise Reduction Using Stereo Vision System in Image Monitoring System)

  • 김수인
    • 조명전기설비학회논문지
    • /
    • 제23권9호
    • /
    • pp.83-90
    • /
    • 2009
  • 본 논문은 스테레오 영상의 깊이정보특성을 이용하여 물체의 이등성분과 외란광에 의해 오인식되는 이동성분을 구분하여 외란광에 의한 오인식률을 경감하기 위한 방법을 제안한다. 추출된 이동성분으로부터 깊이정보의 변화를 측정, 변화가 미약한 경우 외란광으로 인식하여 이동물체가 없는 것으로 판단하도록 하였다. 실험 결과 외란광에 의한 오인식률과 그림자와 같은 허상에 의한 오인식률이 87.3[%]의 감소를 보여 본 논문에서 제안하는 방법의 유용성을 확인하였다.

미국거주 한국인의 저층 공동주택 소음 환경에 대한 주관적 평가 - Athens시 중심으로 - (A Subjective Evaluation on the Noise Environment of the Low - rise Multifamily House of Korean lived in Athens, America)

  • 곽경숙
    • 한국주거학회논문집
    • /
    • 제10권2호
    • /
    • pp.203-212
    • /
    • 1999
  • The purpose of this study is to evaluate the Korean residents' subjective opinion of the noise on the lowrise multifamily house in America. The results of this study can be applied for the prevention of noise when planning cities, roads, and multifamily houses in Korea. The subjects of this study are three kinds of multifamily houses and their 124 Korean residents in Athens, America. The results of this study are as follows. The Korean residents felt the noise from lawn mowers and the sound of filter fan of air conditioners were higher than all the other external noise. They were disturbed a little by the external noise. The air borne sound was recognized a little by Korean residents but they only felt moderate sound of building services and household equipment from the solid borne sound of the internal noise. They suffered worse from external noise in the summer and they felt worse from 8~12 o'clock due to external noise and 20~24 o'clock due to internal noise. The Korean residents liked the sound of birds or insects, the sound of cars and trains. However many Korean people in Athens disliked the sounds of birds or insects and lawn mowers more than these sounds in Korea. The Korean residents who were living in the apartment houses felt better than those in the other multifamily houses.

  • PDF

미국 Athens 지역 저층 공동주택 소음 환경평가에 관한 연구 (The Evaluation on the Noise Environment of the Low-rise Multi-family house in Athens,U,S,A)

  • 곽경숙
    • 한국주거학회논문집
    • /
    • 제11권4호
    • /
    • pp.85-96
    • /
    • 2000
  • The purpose of this study was to evaluated noise environment of the low-rise multi-family house in Athens, Georgia. The results of this study can be applied to the prevention of noise when planning multi-family houses, roads and cities in Korea. The subjects of this study were the place of 1m, 10m, 50m, 100m from 4-lane road ofT apartment and 233 residents lived in the low-rise multi-family houses in Athens. The results of this study were as follows. 1. The average noise level at 1m, 10m, 50m and 100m was 55.5dB, 46.7dB, 43.0dB, 43.0dB and 41.2dB respectively from 4-lane road of T apartment. From the view of the standard in this study, the physical noise was good. 2. The results of the residents subjective response on the noise were as follows. The external noise residents felt - that was a noise by operating machines, and traffic noise - ware as 2.57 on average. The noise by the daily activities, the noise of nature are a little as 2.38 on average. They were disturbed a little by the external noise. They felt the solid born sounds(average 2.49) more than airbone sound(average 2.23) by the internal noise. They are suffered worse from noise in summer and they worse from 8-12 oclock due to external noise and 16-20 oclock due to internal noise. Comparing the noise environment of Korean with that of American, I found a meaningful difference of nature and the noise of daily activities of external noise and all internal noise.

  • PDF

GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구 (A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS)

  • 이승민
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

슬림타입 외장형 ODD 내부의 유동 안정을 통한 소음저감에 관한 연구 (A Study on the Noise Reduction through the Control of Internal Flow for a Slim Type External ODD)

  • 이우진;서준호;임윤철
    • 정보저장시스템학회논문집
    • /
    • 제8권2호
    • /
    • pp.72-77
    • /
    • 2012
  • The demand for the laptop computer has been increased day by day and most of users ask quiet computer and devices to work in comfortable environment. One of the devices which generate acoustic noise is an external ODD. Unlike the internal ODD, the external ODD is easy to emit noise because it runs outside of the computer and also it is packed with a thin plastic covers. As the disk rotates, vortex flow is generated inside of the cavity due to various and complicated mold parts of the cover. In addition, there is a gap between the disk tray and the upper/lower cases, through which the air flows as well as the noise leaks. In this study, we have proposed how to reduce the acoustic noise of an external ODD using numerical and experimental analysis. The pressure fluctuations and turbulent kinetic energy distributions are calculated for the developed model. The results show that the sound pressure level is reduced by 2.3dB through simple modifications of ribs of the top cover, which remove or suppress flow instabilities inside of the cavity.

FCM 클러스터링 기반 비선형 기동표적의 외란분석 알고리즘 (External Noise Analysis Algorithm based on FCM Clustering for Nonlinear Maneuvering Target)

  • 손현승;박진배;주영훈
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2346-2351
    • /
    • 2011
  • This paper presents the intelligent external noise analysis method for nonlinear maneuvering target. After recognizing maneuvering pattern of the target by the proposed method, we track the state of the target. The external noise can be divided into mere noise and acceleration using only the measurement. divided noise passes through the filtering step and acceleration is punched into dynamic model to compensate expected states. The acceleration is the most deterministic factor to the maneuvering. By dividing, approximating, and compensating the acceleration, we can reduce the tracking error effectively. We use the fuzzy c-means (FCM) clustering as the method to divide external noise. FCM can separate the acceleration from the noise without criteria. It makes the criteria with the data made by measurement at every sampling time. So it can show the adaptive tracking result. The proposed method proceeds the tracking target simultaneously with the learning process. Thus it can apply to the online system. The proposed method shows the remarkable tracking result on the linear and nonlinear maneuvering. Finally, some examples are provided to show the feasibility of the proposed algorithm.

외부 코로나 노이즈를 제거한 내부 부분방전 측정기법 (An internal partial discharge measurement method excepted an external corona noise)

  • 권동진;진상범;곽희로
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.44-50
    • /
    • 2001
  • 현재까지 운전중인 변압기에 전기적인 부분방전 측정기법을 적용하기 위한 가장 큰 문제점은 외부 코로나 노이즈를 제거하는 것이다. 본 논문에서는 외부 코로나 노이즈를 제거하고 변압기 내부의 결함에 의한 부분방전 신호만을 측정하는 기법에 대하여 연구하였다. 현장에서 운전중인 변압기에서의 부분방전과 코로나 노이즈의 발생 형태를 모의하기 위하여 모의 변압기 내에 침-평판 전극을 이용하여 변압기 내부 부분방전을 발생시켰으며, 동시에 변압기 외부의 공기 중에 봉-구 전극을 이용하여 외부 코로나 노이즈를 발생시켰다. 변압기 접지선에 설치한 로고우스키 코일에는 변압기의 내부 결함에 의해 발생되는 부분방전 신호와 외부 코로나 노이즈가 동시에 측정되었다. 변압기 외부에 안테나 센서를 이용하여 외부 코로나 노이즈를 별도로 측정하여, 코로우스키 코일에서 측정된 신호에서 코로나 노이즈를 제거한 결과, 변압기 내부의 부분방전에 의한 신호만을 효과적으로 검출할 수 있었다.

  • PDF

철도차량 외부소음 예측을 위한 음원모델에 관한 고찰 (Investigation of Source Modelling for External Noise Prediction of Railway Vehicles)

  • 김종년
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1069-1077
    • /
    • 2009
  • For external noise prediction of railway vehicles, sophisticated individual source modelling as well as appropriate noise propagation model from the sources is necessary to ensure the accuracy of the predicted results and contributions of each equipment to the overall noise levels. Accurate and reasonable identification procedures of sound sources of equipment including source strength, directivity and positions installed in the train play an important role in a prediction model, since it is not easy to establish a simple model for the sources with a single rule due to the complexity of source characteristics of equipment in size and directivity pattern. This paper guidelines practical considerations for identification of noise sources in railway vehicles including typical source characteristics of several sub-systems that emits noise to the environment, particularly for electric multiple unit(EMU), and verify effectiveness of assumptions used in the modelling of equipment by measurement with a simple part. The predicted external noise level of a complete train using Exnoise, which was developed by Hyundai-Rotem and has been verified in the a lot of field-tests, incorporating source modelling considered in this paper shows close correlation with the measured ones.

  • PDF

미국 저층 공동주택 거주자의 소음 환경에 대한 주관적 평가 - Athens시를 중심으로 - (A Subjective Evaluation on the Noise Environment of the Low-rise Multifamily House in Athens, U. S. A)

  • 곽경숙
    • 한국가정과학회지
    • /
    • 제1권2호
    • /
    • pp.61-74
    • /
    • 1998
  • The purpose of this study is to investigate residents subjective opinion of the noise on the low-rise multifamily house in U.S.A. The results of this study can be applied for the prevention of noise when planning cities, roads, and multifamily houses in Korea. The subjects of this study are three kinds of multifamily houses and their 109 residents in Athens, U.S.A. The results of this study are as follows. The residents felt the noise from lawn mowers and the sound from filter fans of air conditioners were higher than in the other external noise. The residents daily activities were disturbed a little by the external noise. Of the internal noise, the air home sound was recognized a little by residents. They only felt a moderate sound level from the building services of the solid borne sound. They suffered worse from noise in the summer and they felt worse from 16∼20 o'clock due to noise. The residents who were living in town houses felt better than those in the other multifamily houses. (Korean J Human Ecology 1(2):61∼74. 1998)

  • PDF