• Title/Summary/Keyword: External loading

Search Result 558, Processing Time 0.024 seconds

Effect of the boundary shape of weld specimen on the stress distribution (용접시편의 테두리 모양이 응력 분포에 미치는 영향)

  • Yang, Seung-Yong;Goo, Byeong-Choon
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.348-352
    • /
    • 2004
  • In finite element analysis of mechanical behavior of weld, typical process is first to obtain a finite element model containing residual stress by conducting welding analysis and then to examine the computational specimen for various external loading. The numerical specimen with residual stress has irregular boundary lines since one usually begins the welding analysis from a body having regular straight boundary lines and large thermal contraction takes place during cooling of weld metal. We notice that these numerical weld specimens are different from the real weld specimens as the real specimens are usually cut from a bigger weld part and consequently have straight boundaries neglecting elastic relaxation associated with the cutting. In this paper, an iterative finite element method is described to obtain a weld specimen which is bounded by straight lines. The stress distributions of two types of weld specimen, one with regular and the other with irregular boundaries, are compared to check the effect of the boundary shape. Results show that the stress distribution can be different when large plastic deformation is induced by the application of external loading. In case of elastic small deformation, the difference turns out almost negligible.

  • PDF

Plantar Soft-tissue Stress states in standing: a Three-Dimensional Finite Element Foot Modeling Study

  • Chen, Wen-Ming;Lee, Peter Vee-Sin;Lee, Tae-Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.197-204
    • /
    • 2009
  • It bas been hypothesized that foot ulceration might be internally initiated. Current instruments which merely allow superficial estimate of plantar loading acting on the foot, severely limit the scope of many biomechanical/clinical studies on this issue. Recent studies have suggested that peak plantar pressure may be only 65% specific for the development of ulceration. These limitations are at least partially due to surface pressures not being representative of the complex mechanical stress developed inside the subcutaneous plantar soft-tissue, which are potentially more relevant for tissue breakdown. This study established a three-dimensional and nonlinear finite element model of a human foot complex with comprehensive skeletal and soft-tissue components capable of predicting both the external and internal stresses and deformations of the foot. The model was validated by experimental data of subject-specific plantar foot pressure measures. The stress analysis indicated the internal stresses doses were site-dependent and the observation found a change between 1.5 to 4.5 times the external stresses on the foot plantar surface. The results yielded insights into the internal loading conditions of the plantar soft-tissue, which is important in enhancing our knowledge on the causes of foot ulceration and related stress-induced tissue breakdown in diabetic foot.

The study for Biological nutrient removal of High-strength nitrogen loading rate using B3 pilot plant (B3 Pliot plant를 이용한 고농도 질소부하에서의 고도처리에 관한 연구)

  • Eorn Tae-Kyu;Han Dong-Yueb;Kim Boo-Gil
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.771-775
    • /
    • 2005
  • The purpose of this research was to investigate applicative possibility of field. Pilot-scale experiments were conducted, at outdoor temperature, HRT l0hour, IR(Internal Recycle) $150\%$ and used $2.8m^3$ Reactor. External carbon source was varied 80 to 120 mg/L. When External carbon source and Alkalinity were injected to the B3 pilot plant, the removal efficiencies of COD and BOD were not decreased. Nitrification rate were 5.95, 5.40, 4.08 $mgNH_4^+-N/gSS/d$ during operation periods and denitrification rate was $3.l2mgNO_3^--N/gSS/d.$ When we surveyed the relationship between loading rate of nitrogen and nitrogen removal quantity, this data was 0.949, B3 process will be possible application process of field.

Water Quality Evaluation on the Bottom Water of Masan Bay by Multivariate Analysis (다변량 해석에 의한 마산만 저층수의 수질평가)

  • Lee, Mu-kang;Hwang, Jeung-Wook;Choi, Young-Kwang
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.15-23
    • /
    • 1996
  • During the last two decades, many industrial complexes for heavy and chemical industries have been established along the Korean coastline, thereby increasing the pollution materials burden on the coastal environment of seawater. Masan Bay is one of the most polluted coastal areas in Korea and the main soures of pollutants are domestic and industrial wastewater from Masan, Changwon. This study was aimed to evaluate relationships among the physicochemical parameters in the bottom water of Masan bay and to examine environmental factors affecting to pollutions of seawater by factor analysis. 'rife factor loading, 1 is showed higher increasing inclination after 1989 year in station 1. The variance of pollutant materials is showed 43.7% in which the coastal inflow water is indicated external loadings(factor 1 : NO3--N, TN, factor 4 : SiO2-Si) corresponded to domestic sewage, industrial wastewater, and earth-sands in the bottom water of Masan bay And the internal loadings(factor 2 : SS, salinity, factor 3 . W.T., DO) are explained 33.8%'corresponded the phenomena of sedimentary layer and oxygen concentration. Therefore, The external loadings are explained by the higher factor pollutantal variance in Masan bay.

  • PDF

Buried Polyethylene Gas Pipes Analysis using Finite Element Method under External Loadings (외부 하중에 대한 매설 폴리에틸렌 가스배관의 유한요소 해석)

  • Kil, Seong-Hee;Jo, Do-Young
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.49-55
    • /
    • 2007
  • Polyethylene pipes have been widely used as they are easy to construct and suitable for economical efficient when they are compared with metal pipelines. This paper studies the effect of various external loadings on stress and deflection of the buried PE pipes using Finite Element Method(FEM). For this purpose, stresses of buried PE pipes are calculated according to the loading condition such as pipe types (pipe diameter $50{\sim}400mm$), burial depths ($0.6{\sim}1.2m$) and internal pressures ($0.4{\sim}4bar$). As a result, it is founded the effect and relation with each of loading conditions under the buried condition.

  • PDF

Effect of external compressive load during a continuous radio-frequency /vacuum process on movement behavior

  • Lee, Nam-Ho;Jin, Young-Moon
    • Journal of the Korea Furniture Society
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • Movement behavior, shrinkage and equilibrium moisture content (EMC), in this experiment reflected a change of hygroscopicity mainly affected by continuously compressive load during radio-frequency/vacuum (RF/V) drying and humidity changes during equilibrating. As a result of interaction of the compressive load and moisture content changing under the RF/V condition, the shrinkages in loading direction were significantly increased while those perpendicular to loading direction were decreased. The shrinkages were affected most in tangential, and least in longitudinal direction. The shrinkages showed higher values in continuous drying than in intermittent drying. In the direction of increased shrinkage, all the movements were also increased, for example, the tangential movement for the loaded-RS and the radial movement for loaded-TS; in the direction of decreased shrinkage, all the movements except the tangential movement for the loaded-TS were decreased such as the tangential and radial movements for the loaded-ES, and the radial movement for the loaded-RS, comparing with those of the load-free. EMCs of the loaded specimens were all higher than that of the load-free specimen, and the highest for the loaded-TS, the lowest for the loaded-ES. The transverse hygroscopicity of specimen was reduced for the loaded-ES, but increased for the loaded-TS.

  • PDF

Substructural parameters and dynamic loading identification with limited observations

  • Xu, Bin;He, Jia
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.169-189
    • /
    • 2015
  • Convergence difficulty and available complete measurement information have been considered as two primary challenges for the identification of large-scale engineering structures. In this paper, a time domain substructural identification approach by combining a weighted adaptive iteration (WAI) algorithm and an extended Kalman filter method with a weighted global iteration (EFK-WGI) algorithm was proposed for simultaneous identification of physical parameters of concerned substructures and unknown external excitations applied on it with limited response measurements. In the proposed approach, according to the location of the unknown dynamic loadings and the partially available structural response measurements, part of structural parameters of the concerned substructure and the unknown loadings were first identified with the WAI approach. The remaining physical parameters of the concerned substructure were then determined by EFK-WGI basing on the previously identified loadings and substructural parameters. The efficiency and accuracy of the proposed approach was demonstrated via a 20-story shear building structure and 23 degrees of freedom (DOFs) planar truss model with unknown external excitation and limited observations. Results show that the proposed approach is capable of satisfactorily identifying both the substructural parameters and unknown loading within limited iterations when both the excitation and dynamic response are partially unknown.

Strengthening of deficient RC joints with diagonally placed external C-FRP ropes

  • Karayannis, Chris G.;Golias, Emmanouil
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.123-132
    • /
    • 2021
  • Deficient beam-column joints of reinforced concrete (RC) structures designed to older practices and codes often lead to destructive local or global failures. A strengthening technique for these joints based on the use of the new and innovative Carbon-FRP (C-FRP) ropes is presented and investigated. The C-FRP ropes are diagonally placed in superficial notches on the two sides of the joint. Two full scale external substandard joint subassemblages with the same characteristics, one unstrengthened and one strengthened with diagonally applied C-FRP ropes, are constructed and tested in cyclic loading. Special attention has been given to the elaboration of the acquired test measurements. The extracted conclusions are based on the comparative study of the hysteretic responses of the specimens, the observed maximum load envelopes, the comparisons of the joint body shear deformations as measured using diagonally mounted LVTDs, the calculated nominal principal stresses developed in the joint regions, the assessed joint damage as expressed by the damage index by Park and Ang and finally the calculated values of the equivalent damping ratio. From these comparisons it is concluded that application of diagonally mounted C-FRP ropes on the two sides of the joint body of exterior connections is an efficient easy-to-apply technique for the strengthening of substandard RC joints.

Modeling fire performance of externally prestressed steel-concrete composite beams

  • Zhou, Huanting;Li, Shaoyuan;Zhang, Chao;Naser, M.Z.
    • Steel and Composite Structures
    • /
    • v.41 no.5
    • /
    • pp.625-636
    • /
    • 2021
  • This paper examines the fire performance of uninsulated and uncoated restrained steel-concrete composite beams supplemented with externally prestressed strands through advanced numerical simulation. In this work, a sequentially coupled thermo-mechanical analysis is carried out using ABAQUS. This analysis utilizes a highly nonlinear three-dimensional finite element (FE) model that is specifically developed and validated using full-sized specimens tested in a companion fire testing program. The developed FE model accounts for nonlinearities arising from geometric features and material properties, as well as complexities resulting from prestressing systems, fire conditions, and mechanical loadings. Four factors are of interest to this work including effect of restraints (axial vs. rotational), degree of stiffness of restraints, the configuration of external prestressed tendons, and magnitude of applied loading. The outcome of this analysis demonstrates how the prestressing force in the external tendons is primarily governed by the magnitude of applied loading and experienced temperature level. Interestingly, these results also show that the stiffness of axial restraints has a minor influence on the failure of restrained and prestressed steel-concrete composite beams. When the axial restraint ratio does not exceed 0.5, the critical deflection of the composite beam is lower than that of the composite beam with a restraint ratio of 1.0.

CCQC modal combination rule using load-dependent Ritz vectors

  • Xiangxiu Li;Huating Chen
    • Structural Engineering and Mechanics
    • /
    • v.87 no.1
    • /
    • pp.57-68
    • /
    • 2023
  • Response spectrum method is still an effective approach for the design of buildings with supplemental dampers. In practice, complex complete quadratic combination (CCQC) rule is always used in the response spectrum method to consider the effect of non-classical damping. The conventional CCQC rule is based on exact complex mode vectors. Sometimes the calculated complex mode vectors may be not excited by the external loading and errors in the structural responses always arise due to the mode truncation. Load-dependent Ritz (LDR) vectors are associated with the external loading and LDR vectors not excited can be automatically excluded. Also, contributions of higher modes are implicitly contained in the LDR vectors in terms of static responses. To improve the calculation efficiency and accuracy, LDR vectors are introduced in the CCQC rule in the present study. Firstly, the generation procedure of LDR vectors suitable for non-classical damping system is presented. Compared to the conventional LDR vectors, the LDR vectors herein are complex-valued and named as complex LDR (CLDR) vectors. Based on the CLDR vectors, the CCQC rule is then rederived and an improved response spectrum method is developed. Finally, the effectiveness of the proposed method in this paper is verified through three typical non-classical damping buildings. Numerical results show that the CLDR vector is superior to the complex mode with the same number in the calculation. Since the generation of CLDR vectors requires less computational cost and storage space, the method proposed in this paper offers an attractive alternative, especially for structures with a large number of degrees of freedom.