• 제목/요약/키워드: External load

검색결과 1,321건 처리시간 0.024초

이중 EHA의 제어 특성 개선 (Control-performance Improvement of Dual EHAs)

  • 이성렬;홍예선
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권3호
    • /
    • pp.32-38
    • /
    • 2016
  • For this paper, the position-control performances of dual EHA(electro-hydrostatic actuator) systems were investigated according to two cases wherein the double-rod- and single-rod-type hydraulic cylinders were combined. Since the control performance is significantly dependent on the load conditions including external forces such as the inertia load, it is proposed here that the two sub-EHAs are driven by separate position and force controllers, instead of two identical position controllers. According to the simulation results, the best performance was achieved by the position-controlled single-rod-type EHA that was combined with a force-controlled double-rod-type EHA. As the force-controlled double-rod-type EHA compensated for the external loads on the position-controlled single-rod-type EHA, the position-control performance was not influenced by external forces including the inertia load. In addition, the position-controlled single-rod-type EHA contributed to the enhancement of the damping ratio by absorbing the pressure peaks through its internal accumulator. Due to the symmetrical piston areas, the double-rod-type EHA is more suitable for force control than the single-rod- type EHA.

Experimental study of moment redistribution and load carrying capacity of externally prestressed continuous composite beams

  • Chen, Shiming;Jia, Yuanlin;Wang, Xindi
    • Structural Engineering and Mechanics
    • /
    • 제31권5호
    • /
    • pp.605-619
    • /
    • 2009
  • A comparative experimental study of prestressed continuous steel-concrete composite beams was carried out. Two continuous composite beams were tested, one of which was plain continuous steel-concrete composite beam, while the other was a composite beam prestressed with external tendons. Cracking behavior and the load carrying capacity of the beams were investigated experimentally. Full plasticity was developed in the mid-span section each beam, the maximum moments attained at the internal support sections however were governed by local buckling which was related to the slenderness of composite section. It was found that in hogging moment regions, the ultimate resistance of an externally prestressed composite beam would be governed by either distortional lateral buckling or local buckling, or interactive mode of these two buckling patterns. The results show that exerting prestressing on a continuous composite beam with external tendons will increase the extent of internal force and moment redistribution in the beam. The influences of local and distortional buckling on the behaviors of the composite continuous beams are discussed. The Moment redistribution and the load carrying capacity of the prestressed continuous composite beams are evaluated, and it is found that at the ultimate state, the moment redistribution in the prestrssed continuous composite beams is greater than that in non-prestressed composite beams.

Uni-axial behaviour of normal-strength CFDST columns with external steel rings

  • Dong, C.X.;Ho, J.C.M.
    • Steel and Composite Structures
    • /
    • 제13권6호
    • /
    • pp.587-606
    • /
    • 2012
  • Concrete-filled-steel-tubular (CFST) columns have been well proven to improve effectively the strength, stiffness and ductility of concrete members. However, the central part of concrete in CFST columns is not fully utilised under uni-axial compression, bending and torsion. It has small contribution to both flexural and torsion strength, while it can be replaced effectively by steel with smaller area to give similar load-carrying capacity. Also, the confining pressure in CFST columns builds up slowly because the initial elastic dilation of concrete is small before micro-crackings of concrete are developed. From these observations, it is convinced that the central concrete can be effectively replaced by another hollow steel tube with smaller area to form double-skinned concrete-filled-steel-tubular (CFDST) columns. In this study, a series of uni-axial compression tests were carried out on CFDST and CFST columns with and without external steel rings. From the test results, it was observed that on average that the stiffness and elastic strength of CFDST columns are about 25.8% and 33.4% respectively larger than CFST columns with similar equivalent area. The averaged axial load-carrying capacity of CFDST columns is 7.8% higher than CFST columns. Lastly, a theoretical model that takes into account the confining effects of steel tube and external rings for predicting the uni-axial load-carrying capacity of CFDST columns is developed.

최대전력점추적방법과 외부저항 제어 알고리즘을 이용한 미생물연료 전지의 전력생산 최대화 (Improvement of Power Generation of Microbial Fuel Cells using Maximum Power Point Tracking (MPPT) and Automatic Load Control Algorithm)

  • 송영은;김중래
    • KSBB Journal
    • /
    • 제29권4호
    • /
    • pp.225-231
    • /
    • 2014
  • A microbial fuel cell (MFC) and bioelectrochemical systems are novel bioprocesses which employ exoelectrogenic biofilm on electrode as a biocatalyst for electricity generation and various useful chemical production. Previous reports show that electrogenic biofilms of MFCs are time varying systems and dynamically interactive with the electrically conductive media (carbon paper as terminal electron acceptor). It has been reported that maximum power point tracking (MPPT) method can automatically control load by algorithm so that increase power generation and columbic efficiency. In this study, we developed logic based control strategy for external load resistance by using $LabVIEW^{TM}$ which increases the power production with using flat-plate MFCs and MPPT circuit board. The flat-plate MFCs inoculated with anaerobic digester sludge were stabilized with fixed external resistance from $1000{\Omega}$ to $100{\Omega}$. Automatic load control with MPPT started load from $52{\Omega}$ during 120 hours of operation. MPPT control strategy increased approximately 2.7 times of power production and power density (1.95 mW and $13.02mW/m^3$) compared to the initial values before application of MPPT (0.72 mW and $4.79mW/m^3$).

Gravel Mat로 보강된 말뚝지지 전면기초의 실내모형실험 (Laboratory Test of Piled-Raft Foundation Improved by Gravel Mat)

  • 서영교;이정훈
    • 한국해양공학회지
    • /
    • 제25권2호
    • /
    • pp.47-54
    • /
    • 2011
  • A piled raft foundation is one of the systems used to reduce the settlement of structures. However, the general design method for a piled raft foundation system assumes that the piles only support external loads, which exclude the bearing capacity of the raft itself. In this study, an experimental model test was performed to evaluate the raft capacity for the external load on the sand. Additionally, a part of the sandy ground under the raft was replaced with a gravel mat to reinforce the piled raft foundation system and increase the bearing capacity. Then, parametric studies of the reinforced ground were performed to determine the displacement and load-sharing ratio of the piled raft foundation system.

Fully-coupled 시뮬레이션을 이용한 해상 monopile 풍력 발전기의 응력해석 (Load analysis of an offshore monopile wind turbine using fully-coupled simulation)

  • ;박현철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.480-485
    • /
    • 2009
  • Offshore wind energy is gaining more attention. Ensuring proper design of offshore wind turbines and wind farms require knowledge of the external conditions in which the turbines and associated facilities are to operate. In this work, a three-bladed 5MW upwind wind turbine, which is supported by the monopile foundation, is studied by use of fully coupled aero-hydro-servo-elastic commercial simulation tool, 'GH-Bladed'$^{(R)}$. Specification of the structures are chosen from the OC3 (Offshore Code Comparison Collaboration) under "IEA Wind Annex XXIII-subtask2". The primary external conditions due to wind and waves are simulated. Design Load case 5.2 is investigated in this work. The steady state power curve and power production loads are evaluated. Comparison between different codes is made.

  • PDF

LED 가로등 및 보안등기구의 절연특성 연구 (A Study on the Insulation Characteristics of LED Lamps for Load and Street Lighting)

  • 김향곤;길형준;김동욱;김동우
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.546-551
    • /
    • 2009
  • In this paper, we studied insulation characteristics of LED lamps for load and street lighting. LED lamps can be divided into internal type and external type according to converter type. In this study, we analyzed technology standard, K(Electrical Appliances Safety Standards) and KS(Korean Industrial Standards) about insulation resistance for LED lamps for load and street lighting, and measured insulation resistances for each measured point. Mostly, insulation resistances were measured high more than regulation value but some measured points were measured badly. We expect that the results of these experiments would be helpful for electrical safety of LED lighting installation, manufacture, construction and maintenance.

Crashworthiness analysis on existing RC parapets rehabilitated with UHPCC

  • Qiu, Jinkai;Wu, Xiang-guo;Hu, Qiong
    • Computers and Concrete
    • /
    • 제19권1호
    • /
    • pp.87-98
    • /
    • 2017
  • In recent year, the coat layer drops and the rebar rust of bridge parapets, which caused the structural performance degradation. In order to achieve the comprehensive rehabilitation, ultra high performance cementitious composites is proposed to existing RC parapet rehabilitation. The influence factors of UHPCC rehabilitation includes two parts, i.e., internal factors related with material, such as UHPCC layer thickness, corrosion ratio of rebars, fiber volume fraction, and external factors related with the load, such as impact speeds, impact angles, vehicle mass. The influence of the factors was analyzed in this paper based on the nonlinear finite element. The analysis results of the maximum dynamic deformation and the peak impact load of parapets revealed the influence of the internal factors and the external factors on anti-collision performance and degree degradation. This research may provide a reference for the comprehensive multifunctional rehabilitation of existing bridge parapets.

외부 평면파에 의해 유기되는 연쇄 접속 전송선로의 부하전류 해석 (An Analysis of Load Current for Cascaded Transmission Line Excited by External Plane Wave)

  • 박영태;이상설
    • 한국통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.232-242
    • /
    • 1990
  • 외부 평면파에 의해 유기되는 단일 전송선로의 EMI(Electromagnetic Interference) 전류에 관한 Smith의 해석법을 이용하여 연쇄 접속된 전송선로의 부하 EMI전류를 구한다. 동일한 특성 임피던스를 갖는 선로가 연쇄 접속 되었다는 가정하에 수치계산을 하여 Smith의 연구 결과와 비교한 결과 두 결과가 잘 일치함을 확인하였으며, 선로의 폭과 길이가 각각 1/10로 줄어들면 부하 EMI 전류는 약 40dB 정도 감소함을 알 수 있었다.

  • PDF

Simplified analytical model for flexural response of external R.C. frames with smooth rebars

  • Campione, Giuseppe;Cannella, Francesco;Cavaleri, Liborio;Monaco, Alessia
    • Structural Engineering and Mechanics
    • /
    • 제66권4호
    • /
    • pp.531-542
    • /
    • 2018
  • In this paper an analytical model in a closed form able to reproduce the monotonic flexural response of external RC beam-column joints with smooth rebars is presented. The column is subjected to a constant vertical load and the beam to a monotonically increasing lateral force applied at the tip. The model is based on the flexural behavior of the beam and the column determined adopting a concentrated plasticity hinge model including slippage of the main reinforcing bars of the beam. A simplified bilinear moment-axial force domain is assumed to derive the ultimate moment associated with the design axial force. For the joint, a simple truss model is adopted to predict shear strength and panel distortion. Experimental data recently given in the literature referring to the load-deflection response of external RC joints with smooth rebars are utilized to validate the model, showing good agreement. Finally, the proposed model can be considered a useful instrument for preliminary static verification of existing external RC beam-column joints with smooth rebars for both strength and ductility verification.