• 제목/요약/키워드: External flame

Search Result 106, Processing Time 0.027 seconds

Effects of acoustic excitation on the combustion emission characteristics of a non-premixed flame (비예혼합 화염에서 음향 가진이 연소 배출 특성에 미치는 영향)

  • Lee, Kee-Man;Park, Jeong;Cho, Han-Chang
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.878-883
    • /
    • 2001
  • The effects of external excitation with various frequencies and amplitudes on the flame behavior and pollution emission characteristics from a laminar jet flame are experimentally investigated. Measurements of $NO_{x}$ emission indices($EINO_{x}$), performed in unconformed and vertical lifted flame at resonance frequency by strong excitation, have been conducted experimentally. It was also conducted to investigate the effects of excited frequency on $NO_{x}$ emissions with a various frequency ranged 0Hz to 2kHz. From the vertical lifted flame like turbulent of the excited jet with resonance frequency was shown that the dependence of $NO_{x}$ emission could be categorized into three groups: Group 1 of intermediate flame length and relative narrow flame volume yielding low $NO_{x}$ emission, Group 2 of short flame length but large flame volume yielding high $NO_{x}$ emission and Group 3 of long flame length with low temperature contours yielding high $NO_{x}$ emission.

  • PDF

A STUDY ON THE FLAMMABILITY OF NON-FLAME-RETARDANT AND FLAME-RETARDANT MATERIALS BY USING CONE CALORIMETER

  • Yanai, Eiji;Suzuki, Takeshi;Yamada, Tokiyoshi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.85-92
    • /
    • 1997
  • Flammability of non-flame-retardant and flame-retardant materials was studied by using cone calorimeter Also, relations between the results obtained by using cone calorimeter and those obtained by the flammability test of japanese fire Service Law were examined. The results are as follows: 1) The ignition time of the molten specimens is relatively long, whereas the ignition time of the non-molten specimens is short. None of remarkable difference of the ignition time has been found between non-flame-retardant and flame-retardant materials specimens. 2) The peak heat release rates of flame-retardant materials are smaller than those of non-flame- retardant materials. 3) The carbon monoxide and smoke evolved from flame-retardant materials generate much more than those evolved from non-flame-retardant materials. 4) Even if flame-retardant materials are passed by the flammability test of Japanese Fire Service Law, they burn easily under external radiative heating condition.

  • PDF

The fire patterns of vinyl and rubber cords shorted by external flame (외부화염에 의해 단락된 비닐코드 및 고무코드의 화재 패턴)

  • Kim, Dong-Woo;Shong, Kil-Mok;Kim, Dong-Ook;Kim, Young-Seok;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1655-1657
    • /
    • 2004
  • The electrical fire frequently happens through carelessness of a vinyl and rubber cords such as a poor contact, a mechanical stress and so on. Electrical fire occupies the greater part(about 30%) of all fires in Korea. In this paper, we compared to the fire dispersive patterns of vinyl and rubber cords according to the external flame in the wall-model. The fire progress and dispersive patterns were measured by a high speed imaging system(HG-100K, REDLAKE, USA). From the results, short-circuit of the vinyl cords are easy to happen than the rubber cords by the external flame. The pattern of fire was progressed a flashover, scattering and disconnection. The fire progress on the vinyl cord is not observed because the ignition energy decreases. However, the fire was progressed continuously on the rubber cord.

  • PDF

NO Reduction and High Efficiency Combustion by Externally Oscillated Staging Burner

  • Lim, Mun-Sup;Yang, Won;Chun, Young-Nam
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.158-163
    • /
    • 2009
  • It is difficult for a burner to achieve an increase in combustibility and a reduction of NOx emission, simultaneously. The reason is because thermal NOx could be reduced at low temperature, while the combustibility should be decreased. To solve this problem, an externally oscillated staging burner was developed, and experiment was conducted according to effective parameters. The combustibility could be improved through the accelerated transfer of heat, mass and momentum obtained by external oscillation. Also, NO is reduced by the decrease of residence time of burning gas in the local highest-temperature spot, which is decreased by the external oscillation and fuel staging. Experiments on variables were conducted to determine the reference flame, and the flame generating the lowest NO concentration was selected. The conditions of reference flame were oscillation frequency 250 Hz, sound pressure 1 VPP, and air ratio 1.1, and NO and CO concentrations were 1ppm and 20 ppm, respectively.

Finding and Analysis of Defective Elements of an LED Streetlight Lamp Based on the Product Liability (PL에 근거한 LED 가로등의 결함 요소 발굴 및 분석)

  • Kim, Hyang-Kon;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.632-632
    • /
    • 2009
  • The purpose of this study is to present the range of defects mentioned in the Product Liability (PL) and to establish an objective basis and grounds for the analysis of accidents expected to happen by analyzing and presenting the external flame pattern and electrical characteristics of an LED streetlight lamp, a new lighting lamp. From the analysis of the cross-section of a cable carbonized by an external flame, it was observed that the wire's strand and insulation material had solidly adhered, and that greater voids were formed at the surface than at the center. Irregular carbide lumps were formed in the globe directly exposed to the flame, and the globe carbonized by the indirect flame showed characteristics that they had melted and flowed downward. It was found that the forward and backward resistances of the normal LED were approximately 1.74 [$M{\Omega}$] and 140 [$M{\Omega}$], respectively. The lamp burnt by the strong flame exhibited infinite forward and backward resistances and the LED did not emit light. The carbonized LED lamp was gray and exhibited fine delaminations. According to the Product Liability, a product defect signifies a simple product defect. Most of the defects were caused by the lack of stability, and the defect of the product itself occurred during the design and manufacture. The defects in warnings and markings include an insufficiency of handling manuals and warnings, expressive warranty violations, defective markings, etc. In order to prevent an accident resulting from a product, it is necessary to prepare safety warnings and documentation, establish clear-cut lines of liabilities, and subscribe insurances. However, it could be seen that important factors against the Product Liability were product improvement, response to compensation requests and law suits, credit restoration, etc.

Study of Flame Response Characteristics to External Acoustic Perturbations (외부압력 교란에 의한 연소반응 연구 고찰)

  • Seo, Seong-Hyeon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.415-418
    • /
    • 2011
  • It is critical to assess the characteristics of flame response to pressure perturbations for the understanding of nonlinear combustion instabilities. Previous studies can be grouped into flame response upon perturbed, fresh air and fuel mixture, and flame response directly perturbed from longitudinal waves. The present study presents experimental methodology for the understanding of the flame response exposed to transverse acoustic waves generated by loud speakers.

  • PDF

Upward Flame Spread for Fire Risk Classification of High-Rise Buildings

  • McLaggan, Martyn S.;Gupta, Vinny;Hidalgo, Juan P.;Torero, Jose L.
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.299-310
    • /
    • 2021
  • External fire spread has the potential to breach vertical compartmentation and violate the fire safety strategy of a building. The traditional design solution to this has been the use of non-combustible materials and spandrel panels but recent audits show that combustible materials are widespread and included in highly complex systems. Furthermore, most jurisdictions no longer require detailing of spandrel panels under many different circumstances. These buildings require rapid investigation using rational scientific methods to be able to adequately classify the fire risk. In this work, we use an extensive experimental campaign of material-scale data to explore the critical parameters driving upward flame spread. Two criteria are outlined using two different approaches. The first evaluates the time to ignition and the time to burnout to assess the ability for a fire to spread, and can be easily determined using traditional means. The second evaluates the preheated flame length as the critical parameter driving flame spread. A wide range of cladding materials are ranked according to these criteria to show their potential propensity to flame spread. From this, designers can use conservative approaches to perform fire risk assessments for buildings with combustible materials or can be used to aid decision-making. Precise estimates of flame spread rates within complex façade systems are not achievable with the current level of knowledge and will require a substantial amount of work to make progress.

Effects of Flow Excitation on the Nitrogen Oxide Emission of a Non-Premixed Flame (유동장 자극이 화염의 질소산화물 배출에 미치는 영향)

  • 이기만
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.34-40
    • /
    • 2004
  • The effects of external flow excitation with various frequencies and amplitudes on the flame behavior and pollution emission characteristics from a laminar jet flame are experimentally investigated. Measurements of $NO_x$ emission indices ($EINO_x$), performed in vertical lifted flame like turbulent with various exciting amplitude at a constant resonance frequency, have been conducted. It was also conducted to investigate the effects of excited frequency at a constant exciting amplitude on $NO_x$ emissions with a various frequency ranged 0 Hz to 2 KHz. From the vertical lifted turbulent flame of the excited jet with resonance frequency by strong excitation was shown that the dependence of $NO_x$ emission could be categorized into three groups Group I of long flame length with high disturbances yielding high $NO_x$ emission, Group II of intermediate flame length and relative narrow flame volume with low disturbance yielding low $NO_x$ emission and Group III of long flame length and large flame volume with high time & space disturbances behaviour yielding high $NO_x$ emission.

Study on Flame Height Equation for the Pinus densiflora Surface Fuel Bed (소나무 낙엽층 화염높이 산정식에 관한 연구)

  • Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.10-15
    • /
    • 2009
  • Flame height calculation in a forest fire is a crucial part of predicting horizontal or vertical flame spread flared by radiation heat transfer. Flame height, which is one of the flame characteristics, can be estimated by the average height of luminous flame. This research relied on flame height observation test on P. densiflora surface fuel bed, which are surface combustibles in a forest, and calorimeter to measure Heat Release Rate, thus produced $H_f=0.027(\dot{Q'})^{2/3}$, flame height calculation equation for surface fuel. The research did not take into consideration such conditions as external velocity, slope and other variables that could affect flame height. According to comparison among experiment results, calculation results of the above formula and those of existing Heskestad formula (1998), it was found that standard error in fallen pine needles between experimental results and calculation results of the above formula amounts to 0.08, whereas standard error in same plant between experimental results and calculation results of existing Heskestad formula amounts to 0.23.

A Study on the Fire Hazards of Puzzle Mats in Group Day Care Home (놀이방 퍼즐매트의 화재위험성에 관한 연구)

  • Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.73-78
    • /
    • 2008
  • The fire hazards and combustion heat of puzzle mats in group day care home were analysed using variable external irradiation level. The fire hazards such as ignition time, ignition temperature, mass loss rate, and flame temperature profile were measured. Incident heat fluxes of $15kW/m^2$, $20kW/m^2$, $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $75kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminium foil. Each sample was nominally 20mm thick and 100mm square. Five samples of puzzle mat were tested in the study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. As results, Type E of FR-grade showed the best characteristics in safety of the early fire from ignition time, critical heat flux, and ignition and flame temperature data of this study. All specimen of G-grade(Type A, B and C), however, showed the weak in safety of fire.