• Title/Summary/Keyword: External exposure dose

Search Result 105, Processing Time 0.027 seconds

Determination of Derived Release Limits by the Concentration Factor Method (농축인자법에 의한 유도방출 기준 설정)

  • Byung Woo Kim;Byeung Kyu Kim;Jeong Ho Lee
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.267-278
    • /
    • 1985
  • Some kinds of methods have been applied to regulate the exposure doses by the radioactive effluents from nuclear power plants. The essential one is primary dose equivalent limit recommended by the ICRP. When the primary limit cannot be applied directly for regulation, there have been dose equivalent index in case of external exposure, or maximum permissible concentration, annual limit on intake, derived air concentration and maximum permissible body burden in case of internal exposure. But the derived limit is required from the viewpoint of discharge, for those values are inadequate to control discharge rate directly. This study was carried out to derive the release limit for the Wolsung nuclear power plant by the concentration factor method. This method is based on the assumption of steady state transfer between environment compartments.

  • PDF

Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose (자외선 조사량에 따른 태양전지 모듈 봉지재의 특성 분석)

  • Lee, Song-Eun;Bae, Joon-Hak;Shin, Jae-Won;Jeon, Chan-Wook
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.81-85
    • /
    • 2018
  • The photovoltaic modules installed in the actual field are affected by various external environments and the electrical performance output value is generally lowered compared to initial output value. The most of photovoltaic modules consists of low iron glass, encapsulant (EVA), back sheet, frame and junction box assembly based on the solar cells. In this paper, the characteristics of encapsulant which is an important constituent material of photovoltaic module were verified by maximum power determination, electro luminescence images, yellowness index measurement, and gel content measurement after ultraviolet (UV) irradiation exposure. The most commonly installed 72 cells crystalline photovoltaic modules were tested after various UV exposure of 0, 15, 30, and $60kWh/m^2$ and compared with the reference module. After UV exposure of $15kWh/m^2$, which is the current international test condition, a small amount of change was observed in yellowness index and electroluminescence, while a gell content rapidly increased. At a cumulative dose of $60kWh/m^2$, which will be a new international test condition in the near future, however, the yellowness index increased sharply and showed the greatest output power drop.

Evaluation of radiological safety according to accident scenarios for commercialization of spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2606-2613
    • /
    • 2022
  • Spent resin often exceeds radiation limits for safe disposal, creating a need for commercial-scale treatment techniques to reduce resin radioactivity. In this study, the radiological safety of a commercialized spent resin treatment device with a treatment capacity of 1 ton/day was evaluated. The results confirm that the device is radiologically safe in the event of an accident. This device desorbs 14C from the spent resin, allowing disposal as low-level waste instead of intermediate-level waste. The device also reduces overall waste by recycling the extracted 14C. Potential accident scenarios were explored to enable dose assessments for both internal and external exposure while preventing further spillage of the device and processing the spilled resin. The scenarios involved the development of a surface fracture on the resin mixture separator and microwave systems, which were operated under pressure and temperature of 0-6 bar and 0-150 ℃, respectively. In the case of accidents with separator and microwave device, the maximum allowable working time of worker were derived, respectively, considering external and internal exposures. When wearing the respirator corresponding to APF 50, in the case of the microwave device accident scenario, the radiological safety was confirmed when the maximum worker worked within 132.1 h.

The Relationship between Urinary 8-hydroxydeoxyguanosine and Polycyclic Aromatic Hydrocarbons Exposure in Working Environment

  • Lee Jong-Seong;Kim Eun-A;Lee Yong-Hag;Moon Deog-Hwan;Kim Kwang-Jong
    • Biomedical Science Letters
    • /
    • v.11 no.2
    • /
    • pp.143-152
    • /
    • 2005
  • To investigate the exposure effect of polycyclic aromatic hydrocarbons (PAHs), we analyzed the relationship between urinary 8-hydroxydeoxyguanosine (8-OHdG) concentration and PAHs exposure. The study population contained 44 workers in steel-pipe coating and paint manufacture industries. We measured airborne total PAHs as an external dose, urinary 1-hydroxypyrene (1-OHP) as an internal dose of PAHs exposure, and urinary 8-OHdG as an effective dose of oxidative DNA damage. There was significant correlation between the urinary concentration of l-OHP and the environmental concentration of PAHs, pyrene, urinary cotinine, AST, and GGT. The mean of urinary 8-OHdG was $17.07\pm1.706{\mu}g/g$ creatinine in workers exposed to airborne PAHs. There was significant correlation between the urinary concentration of 8-0HdG and the airborne concentration of PAHs. From the results of stepwise multiple regression analysis about 8-OHdG, significant independents was total PAHs. In this study, there were significant correlation between the urinary concentration of 8-OHdG and the airborne concentration of PAHs. The urinary 1-OHP was effective index as a biomarker of airborne PAHs in workplace. But it was influenced by non-occupational PAHs source, smoking and biomarkers of liver function test.

  • PDF

Biological indicator on radiation exposure using apoptosis in adult and newborn mice (성숙 및 신생마우스에서 아포프토시스를 이용한 방사선 피폭의 생물학적 지표)

  • Oh, Heon;Lee, Song-eun;Yang, Jung-ah;Jeong, Kyu-shik;Hyun, Byung-hwa;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.679-685
    • /
    • 1998
  • We have studied, by a nonisotopic in situ DNA end-labeling (ISEL) technique, frequency of apoptosis in the external granular layer (EGL) of the cerebellum after whole-body irradiation of newborn mice and intestinal crypt cell of adult mice by gamma-rays from $^{60}Co$. The extent of changes following 2 Gy(10.9 Gy/min) was studied at 2, 4, 6, 8, 12, or 24h after exposure. The maximal frequency was found 4-8h after exposure. The mice that received 0.18, 0.36, 0.54, 1.08, 1.98, or 3.96 Gy were examined 6h after irradiation. Measurements performed after irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model; frequency(%) of apoptotic cell in the newborn mice cerebellum was ($13.49{\pm}1.175$)D+$(-1.52{\pm}0.334)D^2$+0.048($r^2=0.981$, D = dose in Gy) and frequency(number per crypt) of apoptotic cell in the intestinal crypt of adult mice was ($3.857{\pm}0.420$)D+$(-0.535{\pm}0.120)D^2$+0.155($r^2=0.952$, D = dose in Gy). It provides the basis required for a better understanding of results which will be obtained in any further studies for biological responses of radiation using newborn and adult mice.

  • PDF

Study of correlation between airborne benzene and urinary trans,trans-muconic acid in Petrochemical industry processes (공기 중 벤젠과 소변 중 뮤콘산과의 상관성 연구)

  • Joo, Kui Don;Lee, Jong Seong;Choi, Seong Bong;Shin, Jae Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.356-363
    • /
    • 2006
  • To investigate the exposure effect of benzene, we measured airborne benzene as external doses, uninary tt-muconic acid as an internal dose of benzene exposure and analyzed the relationship between tt-muconic acid concentration and benzene exposure. The study population of eight businesses included 157 workers(87 workers in field; exposure group, 70 workers in board; control group) who produce or use benzene in petrochemical industry. The concentrations of airborne benzene were evaluated by personal samples and urine was sampled at the pre and end shift. Urinary t,t-muconic acid as internal dose was to analyze the relationship with airborne benzene. The geometric means(GM) of airborne benzene was 0.0231 ppm(range ND-1.0471 ppm) in exposure group and 0.0147 ppm(range ND-0.3162 ppm) in control group. The geometric means(GM) of urinary t,t-muconic acid at end-shift was $196.8{\pm}2.23{\mu}g/g$ creatinine in exposure group and $149.2{\pm}2.08{\mu}g/g$ creatinine in control group. There was significant correlation between the airborne concentration of benzene and the urinary concentration of t,t-muconic acid( r=0.711, p<0.01). From the results of stepwise multiple regression analysis about t,t-muconic acid at end-shift, significant independents was airborne benzene. In this study, there were significant correlation between the urinary concentration of t,t-muconic acid and the airborne concentration of benzene. More extensive studies ruling out healthy worker effect is needed.

Assessment of Potential Radiation Dose Rates to Marine Organisms Around the Korean Peninsula

  • Lee, Dong-Myung;Lee, Jun-ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Background: It is very difficult to set a regulatory guidance or criteria for the protection of non-human species from the ionizing radiation, because there are no generally or internationally accepted methods for demonstrating the compliance with such criteria. It is needed that Korea develop the primary dose rate standards for the protection of both aquatic and terrestrial biota in the near future. Materials and Methods: The potential dose rates due to both external and internal radiation exposures to marine organisms such as plaice/flounder, gray mullet, and brown seaweed collected within territorial seas around the Korean Peninsula were estimated. Results and Discussion: The total dose rates to plaice/flounder, gray mullet and brown seaweed due to $^{40}K$, a primordial radionuclide in marine environment, were found to be 0.2%, 0.08% and 0.3% of approximately the values of the Derived Consideration Reference Levels (DCRLs, i.e. $1-10mGy{\cdot}d^{-1}$), respectively, as suggested by the International Commission on Radiological Protection (ICRP) publication 124. The total dose rates to marine fishes and brown seaweed due to anthropogenic radionuclides such as $^{90}Sr$, $^{137}Cs$ and $^{239+240}Pu$ were considered to be negligible compared to the total dose rate due to $^{40}K$. The external exposure to benthic fish due to all radionuclides was much higher than that of pelagic fish. Conclusion: From this study, it is recommended that the further study is required to develop a national regulatory guidance for the evaluation of doses to non-human species.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Application of Oral Absorption in Establishment of AOEL for Pesticides and Occupational Risk Assessment for farm worker (경구흡수율을 반영한 농약의 AOEL 설정 및 농작업자 위해성 평가)

  • You, Are-Sun;Hong, Soonsung;Lee, Je Bong;Lee, Seungdon;Ihm, Yangbin
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.342-349
    • /
    • 2014
  • Methods of establishment of AOEL (Acceptable Operator Exposure Level), application of oral absorption by country, and calculation of exposure dose for operator risk assessment in USA, EU and Korea were investigated. Oral absorption of 141 active substances for pesticides was also investigated, then operator risk assessment was conducted with AOEL including oral absorption and Korean AOEL. Internal dose converted to external dose with oral or dermal absorption in USA and EU, but external dose to which oral absorption was not applied was used for establishment of AOEL in Korea. Oral absorption of 50 active substances among 141 were below 80%. In case of application of oral absorption as a correction factor in below 80%, AOELs of about 36% active substances were considered to be lower than the current Korean AOELs. Operator risk assessment of 28 active substances among 50 active substances with oral absorption below 80% was conducted with EU AOELs. TER (Toxicity Exposure Ratio) of 12 plant protection products including chlorothalonil WG (Water-dispersible Granule) was less than 1 and the risk was high. Operator risk assessment of 24 active substances among 50 active substances with oral absorption below 80% was conducted with Korean AOELs. TER of 6 plant protection products including chlorothalonil WG were less than 1 and the risk was high. Operator risk assessment of 4 plant protection products not having Korean AOEL was conducted with converted EU AOEL into AOEL not including oral absorption. The results indicated TER of 4 products including daminozide WP (Wettable Powder) was over 1 and risk was low. 22 products except 6 products such as oxadiagyl SC (Suspension Concentration) were shown the same results of risk assessment between EU AOELs and Korean AOELs. As a result, it was considered that AOELs including oral absorption was possible to be used for operator risk assessment. It was considered operator risk assessment with AOEL including oral absorption was more like real assessment method, and improvement of assessment was needed for application to evaluate pesticides in registration.

Advances in Dose Assessment for External Radiation Exposure (외부방사선피폭(外部放射線被曝)에 대한 선량평가(線量評價)의 동향(動向))

  • Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.2
    • /
    • pp.152-161
    • /
    • 1986
  • 외부방사선피폭(外部放射線被曝)으로 인한 위험(危險)의 평가(評價)와 관련된 량(量) 및 개념(槪念)의 동향(動向)과 미해결(未解決)된 문제점(問題點)들에 대하여 살펴보았다. 특히 ICRU 39의 실용량(實用量)에 근거(根據)한 선량환산인자(線量換算因子), 선질계수(線質係數)의 재정의(再定義), 성별(性別)에 따른 위험(危險)의 차이(差異) 그리고 기타조직(其他組織)의 선정문제등(選定問題等)에 대하여 구체적(具體的)으로 논(論)하였다.

  • PDF