• Title/Summary/Keyword: External change

Search Result 1,756, Processing Time 0.034 seconds

Nonlocal thermo-electro-mechanical vibration analysis of smart curved FG piezoelectric Timoshenko nanobeam

  • Ebrahimi, Farzad;Daman, Mohsen
    • Smart Structures and Systems
    • /
    • v.20 no.3
    • /
    • pp.351-368
    • /
    • 2017
  • To peruse the free vibration of curved functionally graded piezoelectric (FGP) nanosize beam in thermal environment, nonlocal elasticity theory is applied for modeling the nano scale effect. The governing equations are obtained via the energy method. Analytically Navier solution is employed to solve the governing equations for simply supported boundary conditions. Solving these equations enables us to estimate the natural frequency for curved FGP nanobeam under the effect of a uniform temperature change and external electric voltage. The results determined are verified by comparing the results by available ones in literature. The effects of various parameters such as nonlocality, uniform temperature changes, external electric voltage, gradient index, opening angle and aspect ratio of curved FGP nanobeam on the natural frequency are successfully discussed. The results revealed that the natural frequency of curved FGP nanobeam is significantly influenced by these effects.

Evaluation of the Identification method of Joint Mechanical Properties Using Isokinetic Movement (등속운동을 이용한 관절계 역학적 특성치 정량화 방법의 유용성 평가)

  • 이창한;허지운;김철승;엄광문
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1190-1193
    • /
    • 2004
  • The purpose of this study is to evaluate the possibility of identifying joint damping property through commercially available isokinetic ergometer (BIODEX). The proposed method is to estimate the damping torque of the knee joint from the difference between the external joint torque for maintaining isokinetic movement and the gravity torque of the lower leg. The damping torque was estimated at various joint angular velocities, from which the damping property would be derived. Measurement setup was composed of the BIODEX system with an external force sensor and Labview system. Matlab was used in the analysis of the damping property. The experimental result showed that the small variation in angular velocity due to acceleration and deceleration of the crank arm resulted in greater change of inertial torque than the damping torque, so that the estimation of damping property from the isokinetic movement is difficult.

  • PDF

Numerical Analysis on External Strengthening Effects in Aged Structures (사용중인 구조물의 보강효과에 대한 해석적 연구)

  • 신승교;임윤묵;김문겸;박동철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.455-460
    • /
    • 2002
  • In this study, a numerical analysis that can effectively predict the effect of strengthening of cracked flexural members is developed using axial deformation link elements. Concrete and interface between concrete and repair material are considered as quasi-brittle material. Reinforcing bars and reinforcing steel plates are assumed to perform as elasto-plastic materials. Unloading behavior of axial deformation link element is implemented. In the developed numerical model, a flexural member is intentionally cracked by pre-loading, then, the cracked member is repaired using extra elements, and reloaded. The results from analysis of repaired flexural members agrees well with available experiment results. Also, it was shown that the effect of strengthening and the change of failure mode with respect to the time for strengthening and thickness of repair materials. Based on the results, it was determined that the developed numerical model has a good agreement for determining failure modes and effect of strengthening in cracked flexural members. By utilizing the developed numerical analysis, the time and dimension of external strengthening in an existing cracked flexural member with predition of failure mechanism can be determined.

  • PDF

Inspecting Driving Forces of Business Cycles in Korea

  • Jung, Yongseung
    • East Asian Economic Review
    • /
    • v.23 no.4
    • /
    • pp.409-427
    • /
    • 2019
  • This paper sets up a new Keynesian model with external habit to explore the role of each shock over business cycles in Korea. The estimated model via maximum likelihood shows that the productivity shock plays a pivotal role in explaining the output variations before and after the financial crisis since mid-1970s. It also shows that the model with external habit is more successful in explaining the business cycles in Korea after the Asian financial crisis than the model without habit. The monetary policy shock which dominates by accounting for more than 70 percent of the unconditional variance of the inflation rate before the financial crisis is less important in the inflation rate fluctuations after the financial crisis. This partly reflects the regime change of the monetary policy to the inflation targeting rule after the financial crisis.

A Protection Algorithm Discriminating Between Internal and External Faults for Wind Farms (풍력발전단지 보호를 위한 내외부 고장 판별 알고리즘)

  • Kwon, Young-Jin;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.854-859
    • /
    • 2007
  • A wind farm consists of many wind generator(WG)s therefore, it is generally a complex power system. A wind farm as a distributed generation(DG) affects utility power system. If a conventional protection schemes are applied, it is difficult to detect faults correctly and the schemes can't provide proper coordination in some cases. This paper presents a protection algorithm for a wind farm which consists of a looped collection circuit. Because the proposed algorithm can distinguish between an internal fault and an external fault in a wind farm, The proposed algorithm can disconnect the faulted section in a wind farm. This algorithm is based on an overcurrent protection technique with the change of the ratio of the output current of a generator to the current of the looped line connected to each generator to collect the each generator's power. In addition, operating time of the algorithm is shortened by using the voltage drop at a generator collection point. The performance of the proposed algorithm was verified under various fault conditions using PSCAD/EMTDC simulations.

Periodic Bias Compensation Algorithm for Inertial Navigation System

  • Kim Hwan-Seong;Nguyen Duy Anh;Kim Heon-Hui
    • Journal of Navigation and Port Research
    • /
    • v.28 no.9
    • /
    • pp.803-808
    • /
    • 2004
  • In this paper, an INS compensation algorithm is proposed using the accelerometer from IMU. First, we denote the basic INS algorithm and show that how to compensate the position error when low cost IMU is used. Second, considering the ship's characteristic and ocean environments, we consider with a drift as a periodic external environment change which is affected with exact position. To develop the compensation algorithm, we use a repetitive method to reduce the external environment changes. Lastly, we verify the proposed algorithm through the experiments, where the acceleration sensor is used to acquire real data.

GMI Magnetic Field Sensor based on Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2009.12a
    • /
    • pp.217-219
    • /
    • 2009
  • A GMI magnetic field sensor working based on time-coded principle has been investigated and designed. The laboratory model has been constructed and tested carefully, demonstrating the sensitivity of $3\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. An amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ in length, was chosen to be sensing element which was fit into a small field modulation coil of 60 mm in length. The sensor is working based on a time-coded principle that, with the magnetic field modulation was chosen in range of hundreds of Hz, the change in time interval of two adjacent GMI peaks relating to external DC magnetic field is proportional to the intensity of the external field to be measured. This mechanism has made a great improvement to the linearity of the sensor.

  • PDF

The Effects of Hip Abduction angles on Abdominal Muscle Activity During Leg Raising (다리들기 시 엉덩관절 벌림 각도가 배근육의 근활성도에 미치는 영향)

  • Park, Min-Chull
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.2
    • /
    • pp.165-171
    • /
    • 2012
  • Purpose : The purpose of this study was to investigate the change of abdominal muscle activation during unilateral leg raising in supine position among three hip abduction angles($0^{\circ}$, $15^{\circ}$, $30^{\circ}$). Methods : Twenty eight able-body volunteers who had no medical history of low back and hip joint were recruited for this study. Abdominal muscle activity was recorded using surface EMG from both sides of the rectus abdominis, internal/external oblique muscle during leg raising in each position. Results : The muscle activations induced under the three different positions were compared and results showed that there was significant difference only in the right external oblique muscle activation. Conclusion : This study suggest that leg raising of different hip abduction angles without trunk control has little influence on abdominal muscle co-activation.

A Study of Residents' Demand for External Space of Apartment Site (아파트 외부공간 실태와 조성기법)

  • 김한수
    • Journal of the Korean housing association
    • /
    • v.11 no.3
    • /
    • pp.87-98
    • /
    • 2000
  • This study derives problems of external space utilization site from on-site observation and questionnaire survey in order to suggest solutions for the problems. The main results are follows. First, fences as visual boundaries of apartment site play some negative roles - separation of space and heterogeneity of circumstance. This study suggests green fences to cure this problem. Second, residents want to change space use - ground to be used as green space or space for relaxation in stead of parking lots, elevator hall as social space, and underground as bike parks or health centers. Third, rooftop space, used as empty space or machine storage space, should be designed to be utilized as relaxation space by making easy to enter and exit.

  • PDF

Characteristics of Lightning Impulse Current of Zno Block for Transmission Line Arrester with External Gap (송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.61-62
    • /
    • 2009
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters ate impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF