• Title/Summary/Keyword: External Wall

Search Result 560, Processing Time 0.028 seconds

Evaluation of Flexural Performance of Reinforced Concrete Shear Walls According to Flexural Retrofit by Wall End Excavating (단부 파쇄형 휨 보강에 따른 철근콘크리트 전단벽 휨 성능 평가)

  • Cho, Ui-Jin;Kim, Su-Yong;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.123-133
    • /
    • 2020
  • The purpose of this study is to analyze the method of retrofitting flexural strength and the flexural performance of retrofitted shear walls. There are various ways to reinforce the flexural strength of reinforced concrete shear wall structural systems that have already been built, in the case of that, the external force is increased, and the internal force is insufficient. However, there are various problems, such as excessive flexural stiffness after reinforcement and increasing the thickness and length of the wall. We have developed a retrofit method to solve these problems. The wall end is excavated to place the required vertical rebars, and concrete is poured after placing rebars. This is the same concept as creating wall end boundary elements later on. We also studied the anchorage method of reinforcement and the interaction method between the retrofitting end and the existing wall. The flexural test results for the reinforced concrete shear wall using the studied retrofit method can be predicted according to the sectional analysis and FEM analysis, and there are differences in the plastic hinge length, crack propagation, stiffness degradation and energy dissipation due to the bending depending on the vertical rebar ratio of wall end.

Reliability Analysis of a Quay Wall Constructed on the Deep-Cement-Mixed Ground(Part I: External Stability of the Improved Soil System) (심층혼합처리지반에 설치된 안벽의 신뢰성해석(Part I: 개량지반의 외부안정))

  • Huh, Jung-Won;Park, Ock-Joo;Kim, Young-Sang;Hur, Dong-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.2
    • /
    • pp.79-87
    • /
    • 2010
  • This is the first of the two papers dealing with reliability analyses for external and internal stability of a quay wall constructed on a special foundation. A new practical reliability analysis method is proposed in this paper to evaluate the quantitative risk associated with external stability of a quay wall constructed on the deep cement mixed ground. The method can consider uncertainties in various design variables. For the risk estimation to external stability of the improved soil-quay wall, three corresponding limit state functions of sliding, overturning and bearing capacity are fully defined by introducing concept of the secondary random variable. Three representative reliability methods, MVFOSM, FORM and MCS are then applied to evaluate the failure probabilities of the three limit state functions explicitly expressed in terms of the basic and secondary random variables. From the reliability analysis results, the failure probabilities obtained from the three approaches are very close to each other, and the sliding failure mode appears to be the most critical when the earthquake loading is under consideration.

Case Study of Environmental Segmental Retaining Wall(SRW) Using Greenstone Block (환경친화적 블록식 보강토옹벽의 설계 및 시공사례연구)

  • Han, Jung-Geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.6
    • /
    • pp.19-28
    • /
    • 2004
  • Segmental Retaining Wall(SRW) has been variously applying in Civil and Architecture construction. Recently, the application of environmental element in all type's structures came to essential requirement, and the construction cases of retaining wall using reinforced soil and block are more increased than the past. But, this trend more widely was spread environmental element as landscape work for the backside of reinforced retaining wall as well as block itself. New environmental block, Greenstone Block, developed to apply of this tendency. The retaining wall system using Greenstone can be environmental constructing at both block itself and backside of retaining wall. The material tests, the axial compressive strength test of block and bending test of fiber-pipe, exercised to design and construction of vertical SRW, which were satisfied NCMA standard. Through this procedure, Rewall (ver 1.0) was developed, which can be automation design of SRW including internal stability, external stability and local stability. And these can be considered setback of retaining wall, as well the examples of vertical retaining wall using block presented to satisfying the follows; strength of reinforced geotextile, height of retaining wall, surcharge, types of backfill and groundwater level etc. Many problems investigated on after or before of construction were due to local failure, insufficiency of bearing capacity and groundwater level. Especially, the local failure was many occurred to during compaction or after construction, and the cases of SRW construction is similar to the results of model test on vertical SRW.

A Study on the Thermal Performance Analysis of Curtain Wall Office Building Considering the Thermal Bridges (열교부위를 고려한 커튼월 사무소 건물의 열성능 해석에 관한 연구)

  • Shin, U-Cheul;Kim, Seung-Chul;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.95-100
    • /
    • 2011
  • Currently, office buildings in Korea tend to adopt as their outer wall the curtain wall structure which can be easily constructed and has beautiful external appearance as well. However, the problem is that the curtain wall structure does not have a uniform composition unlike the wall of existing reinforced concrete structures and has a frame made of metal with high heat conduction. Therefore, it is expected that the structure will be highly influenced by the thermal bridge. Thereupon, this study analyzes how to set up the composition of the wall system and heat transmission rate in consideration of the thermal characteristics of the curtain wall structure and applies it in practice by simulation in order to propose a guideline for the energy simulation method of the curtain wall structure and analyze its differences from existing simulation methods.

Behavior of UHPC-RW-RC wall panel under various temperature and humidity conditions

  • Wu, Xiangguo;Yu, Shiyuan;Tao, Xiaokun;Chen, Baochun;Liu, Hui;Yang, Ming;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • v.9 no.5
    • /
    • pp.459-467
    • /
    • 2020
  • Mechanical and thermal properties of composite sandwich wall panels are affected by changes in their external environment. Humidity and temperature changes induce stress on wall panels and their core connectors. Under the action of ambient temperature, temperature on the outer layer of the wall panel changes greatly, while that on the inner layer only changes slightly. As a result, stress concentration exists at the intersection of the connector and the wall blade. In this paper, temperature field and stress field distribution of UHPC-RW-RC (Ultra-High Performance Concrete - Rock Wool - Reinforced Concrete) wall panel under high temperature-sprinkling and heating-freezing conditions were investigated by using the general finite element software ABAQUS. Additionally, design of the connection between the wall panel and the main structure is proposed. Findings may serve as a scientific reference for design of high performance composite sandwich wall panels.

Use of Modern Microscopes in Analysing Fiber and Paper Properties (II)-New Aspect in Fibrillation of Pulp Fibers during Refining-

  • Kim, Chul-Hwan;Keigh R. Wadhams
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.3
    • /
    • pp.60-67
    • /
    • 1999
  • The CLSM and the image analysis technique enhanced observation of fiber wall fibrillation occurred in both the outer and the fiber wall surfaces during refining by non-destructive techniques. In the early stages of refining, it was well observed that a partial separation between the S1 and S2 layer in the secondary wall was made generating a space in the wet fiber walls . With further refining, it was clearly shown that the shear forces imparted by the refiner bar surfaces caused the S1 layer to become totally separated from the S2 layer as well as creating microfibrils. Furthermore, the fibrillation in the inner fiber wall surfaces could be due to the normal force (Fn) by refiner bars, friction force between a fiber and refiner bars (Fs) and inner friction force between fiber walls(fs). It was confirmed that the concept of fibrillation should be extended to fibrillation in the inner fiber wall surfaces as well as internal and external fribrillation.

  • PDF

Development of Stone Curtain Wall Anchor Method for the Constructability Improvement (시공성이 개선된 석재 외장재 앵커공법 개발)

  • Park, Nam Wook;Kim, Jong Seong;Kim, Sung Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.76-77
    • /
    • 2014
  • Stone is one of the oldest and most popular materials used on the external wall because of its durability, abundance and aesthetic effect. However, there are two main problems in the existing pin hole construction method. One is uniformity of construction quality, and the other is a repair work of stone panels. Therefore, a new method is needed to overcome these problems. This paper presents a new stone curtain wall system using under cut anchor and secondary holes that was developed by authors. The improved quality and reduction of construction period can be obtained by this system.

  • PDF

Optically Compensated Bend Cell with Pixel-Isolating Polymer Wall for a Flexible Display Application

  • Lee, Seong-Ryong;Lee, Joong-Ha;Jang, Hong-Jeek;Yoon, Tae-Hoon;Kim, Jae-Chang
    • Journal of Information Display
    • /
    • v.8 no.4
    • /
    • pp.5-9
    • /
    • 2007
  • We demonstrate an optically compensated bend (OCB) cell with pixel-isolating polymer wall. The polymer wall is formed by anisotropic phase separation of LCs and UV-curable polymer. The fabricated cell is initially in ${\pi}-twisted$ state so that it shows uniform and fast bend transition without any transition nucleus. The proposed cell has lower driving voltage than conventional OCB cell. Also, the polymer wall provides mechanical stability, hence preventing distortion of display image from external pressure.

Dynamic Characteristics of Reinforced Concrete Axisymmetric Shell with Initial Imperfection -effect of wall imperfection on the dynamic response- (초기결함을 갖는 철근 콘크리트 축대칭 쉘의 동적 특성;벽체 결함의 영향을 중심으로)

  • 조진구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.3
    • /
    • pp.114-120
    • /
    • 2000
  • In this study a computer program considering initial imperfection of wall of axisymmetric reinforced concrete shell which show plastic deformation by large external loading is developed. initial imperfection of wall of axisymmetric reinforced concrete shell is assumed as sinusoidal curve expressed as {{{{ {W }_{i } }}}}={{{{ {W}_{0 } }}}}sin (n$\pi$y/$\ell$)y. The developed program is applied to the analysis of the dynamic response of axisymmetric reinforced concrete shell when the wall has initial imperfection. The initial imperfection of 0.0 -5.0, and 5cm and steel ratio 0.3, and 5% are tested for numerical examples. The effects of the wall initial imperfection and steel ratio on the dynamic response of the axisymmetric reinforced concrete shell are analysed, It is shown that the direction of the initial imperfection is very important factors for determining the dynamic response.

  • PDF

Acellular dermal matrix and bone cement sandwich technique for chest wall reconstruction

  • Heo, Chan Yeong;Kang, Byungkwon;Jeong, Jae Hoon;Kim, Kwhanmien;Myung, Yujin
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.25-28
    • /
    • 2022
  • The authors performed rigid reconstruction using the sandwich technique for full-thickness chest wall defects by using two layers of acellular dermal matrix and bone cement. We assessed six patients who underwent chest wall reconstruction. Reconstruction was performed by sandwiching bone cement between two layers of acellular dermal matrix. In all patients, there was no defect of the overlying soft tissue, and primary closure was performed for external wounds. The average follow-up period was 4 years (range, 2-8 years). No major complications were noted. The sandwich technique can serve as an efficient and safe option for chest wall reconstruction.