• Title/Summary/Keyword: External Radiation Dose Rate

Search Result 150, Processing Time 0.03 seconds

Adjuvant Radiotherapy Following Radical Hysterectomy and Bilateral Pelvic Lymph Node Dissection for the Uterine Cervical Cancer : Prognostic Factors and Failure Patterns (근칙적 절제술과 술후 방사선치료를 시행한 자궁경부암 환자의 치료성적, 예루인자와 실패양상)

  • Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.357-367
    • /
    • 1997
  • Purpose : To identify variable prognostic factors and analyse failure patterns in the uterine cervix cancer after radical operation and adjuvant radio-therapy, a retrospective analysis was undertaken. Materals and Methods : I analysed one hundred and twenty four patients with uterine cervix cancer, FIGO stage IB, IIA and IIB, treated with radical hysterectomy and pelvic lymph node dissection followed by adjuvant radio-therapy between May 1985 and May 1994. Minimum follow up period was 24 months. All of them were treated with full dose external radiotherapy with linear accelerator and/or high dese rate intracavitary radiation. Results : Overall 5 year survival rate and relapse free survival rate were $75.4\%,\;73.5\%$, respectively. Significant prognostic factors by relapse free survival were wall involvement thickness, lymph node location and number, parametrium involvement, tumor size, stage, uterine body involvement, vaginal resection margin involvement. By multivariate analysis, lymph node matastasis. tumor size and vaginal resection margin involvement were significant prognostic factos. Treatment related failure were 33 cases. Locoregional failure were more likely in the stage IIB, lymph node positive or vaginal resection margin positive patients whereas distant failures were relatively more frequent in stage IB, IIA and lymph node, vaginal resection negative patients. In stage IIB, 5 year relapse free survival rate was only $56\%$ and nine of twenty two patients recurred. Conculsion : Postoperative radiotherapy results are good for patients with relatively low risk factor. But the results are poor for patients with multiple, high risk factors or stage IIB. To control recurrence for patients with high risk factors, postoperative adjuvant radiotherapy is not sufficient treatment method. To raise control rate adding other methods such as radiosensitizing agent or chemotherapy is necessary and prospectively randomized study is needed for evaluation of postoperative radiotherapy efficacy and /or other methods. And it is reasonable to treat primary radical radiotherapy for patients with stage IIB cervical cancer instead of radical operation and adjuvant radiotherapy and/or chemotherapy regimen.

  • PDF

Combined Radiotherapy and Hyperthermia for Nonresectable Hepatocellular Carcinoma (절제 불가능한 원발성 간암의 온열 및 방사선 병용 요법)

  • Seong Jin Sil;Juhn Juhn Kyu;Suh Chang Ok;Kim Gwi Eon;Han Kwang Hyub;Lee Sang In;Roh Jae Kyung;Choi Heung Jai;Kim Byung Soo
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.247-257
    • /
    • 1989
  • Thirty patients with nonresectable hepatocellular carcinoma (HCC) due to either locally advanced lesion or association with liver cirrhosis, treated with combined radiotherapy and hyperthermia between April 1988 and July 1988, at Dept. of Radiation Oncology, Yonsei university College of medicine, were analysed. External radiotherapy of a total dose of 3060cGy/3.5 wks was given. Hyperthermia was given twice a week with a total of 6 treatment sessions using 8MHz radiofrequency capacitive type heating device, i.e., Thermotron RF-8 and Cancermia. In all cases hyperthermia was given within 30 minutes after radiotherapy for 30~60min. Temperature was measured by inserting thermocouple into the tumor mass under the ultrasonographic guidance only for those who had not bleeding tendency. As a result, partial response (PR) was achieved in 12 patients (40%), and symptomatic improvement was observed in 22 patients (78.6%) among 28 patients who had suffered from abdominal pain. The most significant factor affecting the tumor response rate was the type of tumor (single massive: 10/14, 71.4%; diffuse infiltrative: 2/10, 20%; multinodular:0/6, 0%; p<0.005). There were not any significant side effects relating to combined treatment. The overall 1 year survival rate was 34%, with 50% in the PR group and 22% in the no response group (NR), respectively. Median survival was 6.5 months and longer for those of PR than of NR (11 mos. vs 5, p<0.05). In conclusion, combined radiotherapy and hyperthermia appeared to be effective in local control and symptomatic palliation of HCC. Further study including a larger number of the patients to confirm its effect in survival and detrimental side effect should be urged.

  • PDF

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Results of Stereotactic Radiosurgerv with Linear Accelerator for Intracranial Arteriovenous Malformation (두개강내 동정맥기형에서 선형가속기를 이용한 방사선수술의 결과)

  • Lee Kang Kyoo;Park Kyung Ran;Lee Jong Young;Lee Yong Ha
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.215-224
    • /
    • 1997
  • Purpose : Stereotactic radiosurgery with external beam irradiation successfully obliterates carefully selected intracranial arteriovenous malformation (AVM) . We Present clinical and radiological long term results after treatment with a single high dose irradiation using a linear accelerator. Materials and Methods : Rrom January 1991 to June 1994, fifteen patients with intracranial AVM were treated in our hospital with the stereotactic radiosurgery using a linear accelerator. The radiation was delivered using a 6 MV linear accelerator. The prescribed doses at the isocenter varied from 1800 to 2500cGy (median : 2000cGy) and were given as a sin91e fraction. The radiation doses at the periphery of the lesion typically corresponded to the 80-90% isodose line. In 14 patients, complete clinical and/or radiological follow-up examination were available. Results : Angiography was available in 13 patients with a follow-up Period from 18 months to 27 months. Of 13 patients, the overall complete obliteration rate was 92.3% (12 patients). This incidence did not correlate with lesion size. Seizure, headache and progressive neurologic deficit were complete recovered. One Patient experienced hemorrhage at 2 months after treatment. One patient developed radiation induced brain edema in the white matter surrounding nidus at 16 months after treatment and showed complete resolution of the edema in MR image obtained at 27 months after treatment. After a follow-up period of up to 6 years, no radiation induced severe late complications occurred. Conclusion : We conclude that stereotactic radiosurgery using a linear accelerator is an effective and safe therapy for symptomatic and surgically inaccessible intracranial AVMs and the results compare favorably to the more expensive and elaborate systems that are currently available for stereotactic radiosurgery.

  • PDF

Short-term Results of Endobronchial Brachytherapy for Malignant Airway Obstructions (악성 기도 폐쇄에 대한 기관내 근접 조사 방사선치료의 단기 임상 경험)

  • Ahn Yong Chan;Lim Do Hoon;Choi Dong Rak;Kim Moon Kyung;Kim Dae Yong;Huh Seung Jae;Kim Ho Joong;Chung Man Pyo;Kwon O Jung;Rhee Chong Heon
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.299-306
    • /
    • 1996
  • Purpose : Respiratory symptoms related with malignant airway disease have been the main causes of lowered qualify of life and also sometimes may be life-threatening if not properly managed. The authors report the short-term experiences of endobronchial brachytherapy for symptomatic malignant airway obstruction using high dose rate after-loading brachytherapy unit. Materials and Methdos : Twenty-five Patients with symptomatic malignant airway obstruction were treated with endobronchial brachytherapy between the period of December 1994 and March 1996 at Department of Radiation Oncology of Samsung Medical Center Twenty-one ($84\%$) were patients with non-small cell lung cancer, three with tracheal malignancies, and one with recurrence of esophageal cancer. Twenty Patients were given elective external beam radiation therapy, while six were given endobronchial laser evaporation therapy on emergency bases in addition to endobronchial brachytherapy. Three procedures for each patient were planned and total of 70 procedures were completed. Results : Improvement rates of major respiratory symptoms after endobronchial brachytherapy procedures were $88\%$(22/25). $96\%$(22/23), $100\%$ (15/15), and $100\%$(9/9) for cough, dyspnea, hemoptysis and obstructive pneumonia, respectively. ECOG performance scores were improved in $56\%$ of total patients group, while there was no case with worsened ECOG score. Fifteen patients died and the median interval from the start of treatment to death was 4 months (range: $1\~17$ months), while that of ten survivors was 9 months (range $5\~19$ months). There were five patients with controlled intrathoracic disease, who have survived over one rear. All deaths were associated with uncontrolled local and/or distant disease. Four Patients died of massive fatal hemoptysis, three of who received emergency endobronchial laser evaporation therapy before the start of endobronchial brachytherapy. Conclusion : Endobronchial brachytherapy has been confirmed as an excellent palliative treatment modality improving respiratory symptoms as well as patients' general performance status. Based on the current observations, use of endobronchial brachytherapy in curative setting as a boost technique may be warranted.

  • PDF

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

Establishment of Release Limits for Airborne Effluent into the Environment Based on ALARA Concept (ALARA 개념(槪念)에 의한 기체상방사성물질(氣體狀放射性物質)의 환경방출한도(環境放出限度) 설정(設定))

  • Lee, Byung-Ki;Cha, Moon-Hoe;Nam, Soon-Kwon;Chang, Si-Young;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.50-63
    • /
    • 1985
  • A derivation of new release limit, named Derived Release Limit(DRL), into the atomsphere from a reference nuclear power plant has been performed on the basis of the new system of dose limitation recommended by the ICRP, instead of the (MPC)a limit which has been currently used until now as a general standard for radioactive effluents in Korea. In DRL Calculation, a Concentration Factor Method was applied, in which the concentrations of long-term routinely released radionuclides were in equilibrium with dose in environment under the steady state condition. The analytical model used in the exposure pathway analysis was the one which has been suggested by the USNRC and the exposure limits applied in this analysis were those recommended by the USEPA lately. In the exposure pathway analysis, all of the pathways are not considered and some may be excluded either because they are not applicable or their contribution to the exposure is insignificant compared with other pathways. In case, the environmental model developed in this study was applied to the Kori nuclear power plant as the reference power plant, the highest DRL value was calculated to be as $9.10{\times}10^6Ci/yr$ for Kr-85 in external whole body exposure from the semi-infinite radioactive cloud, while the lowest DRL value was observed 3.64Ci/yr for Co-60 in external whole body exposure from the contaminated ground, by the radioactive particulates. The most critical exposure pathway to an individual in the unrestricted area of interest (Kilchun-Ri, 1.3 km to the north of the release point) seems to be the exposure pathway from the contaminated ground and the most critical radionuclide in all pathways appears to be Co-60 in the same pathway. When comparing the actual release rate from KNU-l in 1982 with the DRL's obtained here the release of radionuclides from KNU-1 were much lower than the DRL's and it could be conclued that the exposure to an individual had been kept below the exposure limits recommended by the USEPA.

  • PDF

Early Bowel Complications Following Radiotherapy of Uterine Cervi)( Carcinoma (자궁경부암의 방사선치료 후 급성 장관 합병증)

  • Kim, Won-Dong
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.129-135
    • /
    • 1999
  • Purpose : This study evaluated early bowel complications in cervix cancer patients, following external radiotherapy (ERT and high dose rate intracavitary radiation (HDR ICR). Factors affecting the risk of developing early bowel complications and its incidence are analyzed and discussed Materials and Methods : The study is the retrospective review of 66 patients who received radiotherapy at Chungbuk National University Hospital from April 1994 to December 1998. The patients underwent 41.4 or 50.4 Gy ERT according to FIGO stage and tumor size, then A point dose was boosted to 71.4 or 74.4 Gy using a remotely controlled afterloading Buchler HDR ICR. The EORTC/RTOG morbidity criteria were used to grade early bowel complications, which are valid from day 1, the commencement of therapy, through day 90. The actuarial incidence, severity of complications were investigated and clinical pretreatment factors relevant to complications were found through univariate (Wilcoxon) and multivariate (Cox proportional hazard model) analysis. Results : Of the 66 patients, 30 patients (46$\%$) developed early bowel complications; 25 patients (38$\%$) with grade 1 or 2, 4 patients (0$\%$) with grade 3 and 1 patient (2$\%$) with grade 4. The complications usually began to occur 3 weeks after the commencement of radiotherapy. The actuarial incidence of early bowel complications was 41$\%$ at 10 weeks. The early bowel complications were associated significantly with an old age and a history of previous abdomino-pelvic surgery. All three patients who had a protracted overall treatment time (about 2 weeks) due to severe bowel complication, suffered from pelvic recurrences. Conclusion : Forty six percent of patients experienced early bowel complications, most of which were grade 1 or 2 and relieved spontaneously or by medication. The patients with an old age or a previous surgery have a high probability of early complications and they may be less compliant with planned radiotherapy. So more careful precaution is necessary for these patients.

  • PDF

External Beam Radiotherapy in the Management of Low Grade Astrocytoma of the Brain (뇌 성상세포종 환자의 외부 방사선치료)

  • Chun, Ha-Chung
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Purpose: This study was designed to evaluate the effectiveness of postoperative radiotherapy for patients with low-grade astrocytomas and to define an optimal radiotherapeutic regimen and prognostic factors. Materials and Methods: A total of 69 patients with low-grade astrocytomas underwent surgery and postoperative radiotherapy immediately following surgery at our institution between October 1989 and September 2006. The median patient age was 36 years. Forty-one patients were 40 years or younger and 28 patients were 41 years or older. Fourteen patients underwent a biopsy alone and the remaining 55 patients underwent a subtotal resection. Thirty-nine patients had a Karnofsky performance status of less than 80% and 30 patients had a Karnofsky performance status greater than 80%. Two patients were treated with whole brain irradiation followed by a coned down boost field to the localized area. The remaining 67 patients were treated with a localized field with an appropriate margin. Most of the patients received a dose of $50\sim55$ Gy and majority of the patients were treated with a dose of 54 Gy. Results: The overall 5-year and 7-year survival rates for all of the 69 patients were 49% and 44%, respectively. Corresponding disease free survival rates were 45% and 40%, respectively. Patients who underwent a subtotal resection showed better survival than patients who underwent a biopsy alone. The overall 5-year survival rates for patients who underwent a subtotal resection and patients who underwent a biopsy alone were 57% and 38%, respectively (p<0.05). Forty-one patients who were 40 years or younger showed a better overall 5-year survival rate as compared with 28 patients who were 41 years or older (56% versus 40%, p<0.05). The overall 5-year survival rates for 30 patients with a Karnofsky performance status greater than 80% and 39 patients with a Karnofsky performance status less than 80% were 51% and 47%, respectively. This finding was not statistically significant. Although one patient was not able to complete the treatment because of neurological deterioration, there were no significant treatment related toxicities. Conclusion: Postoperative radiotherapy following surgery is a safe and effective treatment for patients with low-grade astrocytomas. The extent of surgery and age were noted as significant prognostic factors in this study. However, further effective treatment might be necessary in the future to improve long-term survival rates.

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.