• Title/Summary/Keyword: External Quality Assessment

Search Result 79, Processing Time 0.031 seconds

A Study on the Current Status and Improvement Plans for Culinary Education (조리교육 현황과 발전 방안 연구)

  • Lee, Jeong-Ae;Kim, Choong-Ho
    • Culinary science and hospitality research
    • /
    • v.19 no.5
    • /
    • pp.280-295
    • /
    • 2013
  • This study analyzes the differences to examine which education is more effective for practical cooking skills. A survey was conducted on the 4 year university students majoring in culinary arts to examine the recognition levels of culinary practice education for the purpose of searching for an improvement plan for culinary education. The results are as follows. Seniors recognize the importance of learning theory, while the classes offered now are focusing on getting cooking certificates. The students approach cooking not only for eating food but also for the arts, showing increased interests in 'creative food' and 'fusion food.' In class, they feel the necessity of establishing a standard for a fair assessment and English skills for the globalization of food service. Hereupon this study recognizes the current state of culinary education service, draws factors which decide the quality of culinary arts education, and examines student satisfaction with theoretical education, practical education, assessment, and external education by using a factor analysis of twenty quality attributes. Through the development and application of various programs, operation of open practice classes and culinary organization reflecting social changes in learning courses, the culinary arts education is considered to be more vitalized. In this respect, this study introduces four measures which were designed to facilitate the education of highly-skilled human resources in the culinary field.

  • PDF

Quality Grading of Concrete Soil Erosion Control Dam in the Aspect of Unconfined Concrete Strength by Surface-Wave Technique (표면파 기법에 의한 콘크리트 사방댐의 콘크리트 강도 등급 평가)

  • Lee, Chang-Woo;Joh, Sung-Ho;Park, Ki-Hyung;Kim, Min-Sik;Yoon, Ho-Joong;Raja Ahmad, Raja Hassanul
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.412-425
    • /
    • 2012
  • Concrete Soil Erosion Control Dam, which blocks flow of debris flow in torrential stream, are reported to lose expected functions due to structural failure and collapses, caused by poor construction, material deterioration and external impacts. In this paper, an integrity assessment technique for debris barriers was proposed, which allows preliminary detection of problems inherent in debris barriers. The proposed integrity assessment technique is a non-destructive method based on SASW method, one of surface-wave tests. In this paper, a practical procedure and analysis guidelines in applying the SASW technique to debris barrier was proposed and its validity was verified using five decrepit debris barriers older than 20-year old. As a result, the SASW method was validated for the reliable grade evaluation method for concrete soil erosion control dam, and the resulting grades turned out to agree with the results determined by Sabang Associations.

Development of Chicken Carcass Segmentation Algorithm using Image Processing System (영상처리 시스템을 이용한 닭 도체 부위 분할 알고리즘 개발)

  • Cho, Sung-Ho;Lee, Hyo-Jai;Hwang, Jung-Ho;Choi, Sun;Lee, Hoyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.446-452
    • /
    • 2021
  • As a higher standard for food consumption is required, the consumption of chicken meat that can satisfy the subdivided food preferences is increasing. In March 2003, the quality criteria for chicken carcasses notified by the Livestock Quality Assessment Service suggested quality grades according to fecal contamination and the size and weight of blood and bruises. On the other hand, it is too difficult for human inspection to qualify mass products, which is key to maintaining consistency for grading thousands of chicken carcasses. This paper proposed the computer vision algorithm as a non-destructive inspection, which can identify chicken carcass parts according to the detailed standards. To inspect the chicken carcasses conveyed at high speed, the image calibration was involved in providing robustness to the side effect of external lighting interference. The separation between chicken and background was achieved by a series of image processing, such as binarization based on Expectation Maximization, Erosion, and Labeling. In terms of shape analysis of chicken carcasses, the features are presented to reveal geometric information. After applying the algorithm to 78 chicken carcass samples, the algorithm was effective in segmenting chicken carcass against a background and analyzing its geometric features.

Pediatric phantom library constructed from ICRP mesh-type reference computational phantoms (MRCPs)

  • Suhyeon Kim;Bangho Shin;Chansoo Choi;Hyeonil Kim;Sangseok Ha;Beom Sun Chung;Haegin Han;Sungho Moon;Gahee Son;Jaehyo Kim;Ji Won Choi;Chan Hyeong Kim;Yeon Soo Yeom
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3210-3223
    • /
    • 2024
  • International Commission on Radiological Protection (ICRP) recently developed the adult and pediatric meshtype reference computational phantoms (MRCPs) in high-quality/fidelity mesh format, featuring high deformability into various body sizes and poses. Utilizing this feature, the adult MRCPs-based body-size-dependent phantom library was developed for individualized dosimetry. To complete the full phantom library set, the present study produced the pediatric-MRCPs-based body-size-dependent pediatric phantom library. The library comprises a total of 637 phantoms (356 males and 281 females) with varying standing heights and body weights, covering a wide range of body sizes (i.e., including from 1st to 99th percentile height and weight values) for infants, children, and adolescents, offering a realistic representation of body shapes by reflecting ten secondary anthropometric parameters. The phantoms were automatically constructed utilizing automatic deformation program. The dosimetric impact of the library was investigated by calculating organ doses for external exposures to broad parallel photon beams in anterior-posterior direction. Compared with the values of the pediatric MRCPs, significant differences were observed at energies <0.05 MeV, showing larger values for underweight phantom and smaller values for obese phantom. The results highlight the importance of using the pediatric phantom library for accurate dose estimates of individual children with various body sizes.

A Study on the Expected Level of Users of the Public Library - Focused on the Public Library of Goyang - (공공도서관에 대한 이용자 기대수준에 관한 연구 - 고양시 공공도서관을 대상으로 -)

  • Yi, Hyun Jung;Nam, Young Joon
    • Journal of Korean Library and Information Science Society
    • /
    • v.46 no.1
    • /
    • pp.43-63
    • /
    • 2015
  • Quality of the library service, because it is based on the subjective meaning of the user for a particular service, depending on the individual expectation level, can be divided between satisfaction and dissatisfaction. Therefore, library services that are performed in public libraries also ultimately assessment of library services may influence based on the expected value of the user. This study is a satisfaction survey of library services to the public library of Goyang. Overall satisfaction of Public Library of Goyang in this study are in the following orders: 1) facility, 2) cultural programs and courses, 3) librarian kindness, 4) collections. To understand the specific meaning of each preference, it was analyzed in the followings: 1) the expectation level to the library space, 2) expectation level to librarians, 3) new service the users desire, 4) service the users want, etc. by age and occupation. As the age of the user increases, the demand for traditional library usage increased. In addition, services that utilize the same library external resources and utilization of external lecturer is like finding employment and art courses, expectation level of users such as reading course to utilize library resources was the highest.

Precise Orbital and Geodetic Parameter Estimation using SLR Observations for ILRS AAC

  • Kim, Young-Rok;Park, Eunseo;Oh, Hyungjik Jay;Park, Sang-Young;Lim, Hyung-Chul;Park, Chandeok
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.269-277
    • /
    • 2013
  • In this study, we present results of precise orbital geodetic parameter estimation using satellite laser ranging (SLR) observations for the International Laser Ranging Service (ILRS) associate analysis center (AAC). Using normal point observations of LAGEOS-1, LAGEOS-2, ETALON-1, and ETALON-2 in SLR consolidated laser ranging data format, the NASA/GSFC GEODYN II and SOLVE software programs were utilized for precise orbit determination (POD) and finding solutions of a terrestrial reference frame (TRF) and Earth orientation parameters (EOPs). For POD, a weekly-based orbit determination strategy was employed to process SLR observations taken from 20 weeks in 2013. For solutions of TRF and EOPs, loosely constrained scheme was used to integrate POD results of four geodetic SLR satellites. The coordinates of 11 ILRS core sites were determined and daily polar motion and polar motion rates were estimated. The root mean square (RMS) value of post-fit residuals was used for orbit quality assessment, and both the stability of TRF and the precision of EOPs by external comparison were analyzed for verification of our solutions. Results of post-fit residuals show that the RMS of the orbits of LAGEOS-1 and LAGEOS-2 are 1.20 and 1.12 cm, and those of ETALON-1 and ETALON-2 are 1.02 and 1.11 cm, respectively. The stability analysis of TRF shows that the mean value of 3D stability of the coordinates of 11 ILRS core sites is 7.0 mm. An external comparison, with respect to International Earth rotation and Reference systems Service (IERS) 08 C04 results, shows that standard deviations of polar motion $X_P$ and $Y_P$ are 0.754 milliarcseconds (mas) and 0.576 mas, respectively. Our results of precise orbital and geodetic parameter estimation are reasonable and help advance research at ILRS AAC.

The Effect of Hen Age on Egg Quality in Commercial Layer (실용산란계의 산란연령이 계란의 품질에 미치는 영향)

  • Lee, Min Hee;Cho, Eun Jung;Choi, Eun Sik;Bang, Min Hee;Sohn, Sea Hwan
    • Korean Journal of Poultry Science
    • /
    • v.43 no.4
    • /
    • pp.253-261
    • /
    • 2016
  • Egg quality is a very important factor for both consumers and producers. Factors affecting egg quality include strain and age of hens; egg storage temperature, time, and humidity; laying season; and feeding. This study aimed to determine the effect of hen age and egg storage time on egg quality. A total of 700 eggs obtained from Hyline Brown commercial layers were used for this experiment, and they were separated into two hen age groups (30 vs. 60 weeks) with eight treatments and four storage times (day 0, 10, 20, and 30). The egg weight; shell color, thickness, and density; albumen height; Haugh unit (HU); yolk color; and the yolk and albumen pH and viscosity were measured for the egg quality assessment. The results showed that the age of the hen and egg storage time significantly affected almost all parameters of the internal and external egg quality. The shell thickness, albumen height, HU, yolk color, pH of yolk and albumen, and yolk viscosity significantly decreased with increasing hen age. The egg shell color was significantly lighter in eggs from 60-week-old hens than in those from 30 weeks-old hens. The egg weight; shell weight, thickness, and density; albumen height, HU; and albumen viscosity significantly decreased, but the yolk color and pH of the yolk and albumen increased with increasing egg storage time. The interaction effects between the storage time and hen age were significant in shell thickness, albumen height, yolk color, and yolk and albumen pH and viscosity. The eggs obtained from 60-week-old hens showed significantly lower shell thickness, albumen height, and HU values, which are considered typical egg quality measurements, than values of eggs from 30-week-old hens. Therefore, increasing hen age and egg storage time caused the deterioration of egg quality. In conclusion, this study demonstrated that hen age is the major factor affecting the quality of fresh eggs, whereas the storage time is the determinant factor affecting the quality of stored eggs.

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

Revealing the Spatial Distribution of Inorganic Elements in Rice Grains

  • Jeon, Ji Suk;Choi, Sung Hwa;Lee, Ji Yeon;Kim, Ji A;Yang, Young Mi;Song, Eun Ji;Kim, Jae Sung;Yang, Jung Seok;Kim, Kyong Su;Yoo, Jong Hyun;Kim, Hai Dong;Park, Kyung Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3289-3293
    • /
    • 2014
  • Femtosecond laser ablation (fs LA) was used in this study to identify pollution by heavy metals and the distribution of elemental nutrients at different rice milling ratios. Polished rice (degrees of milling of 3, 5, 7, 9, and 11) was collected from major Korean supermarkets and one sample thereof was selected. An internal quality control experiment was conducted using a rice flour certified reference material from the Korea Research Institute of Standards and Science (KRISS CRM) for the evaluation of the efficacy. To assess the effectiveness of the analysis method, the reliability was validated using a food analysis performance assessment scheme (FAPAS), with chili powder serving as an external quality control. The results of the analysis of the inorganic elements Ti, Ca, Al, Fe and Mn in white and brown rice with degrees of milling of 3, 5, 7, 9 and 11 using ICP-MS, ICP-OES and AAS revealed contents of 0.40, 49.2, 2.43, 5.36 and 10.3 mg/kg in white rice and 0.59, 78.0, 7.52, 11.0 and 18.5 mg/kg in brown rice, respectively. Among the elements, there were remarkable differences in the measured contents. By comparing the contents of the elements at different degrees of milling, Ti, Co, As, Ca, Al, Cu, Fe, and Mn were determined to be distributed on the surface of the rice grains, whereas the contents of Cd and Pb increased toward the center of the rice grains, and Si was evenly distributed. After the quantitative analysis of rice samples polished to different degrees of milling, Ca and Al, which were contained in large amounts, and Si were analyzed with specificity by fs LA. The results show that Ca and Al were distributed in the rice husk (protective covering of rice) and Si was distributed in all parts of the rice.

A Study of Six Sigma and Total Error Allowable in Chematology Laboratory (6 시그마와 총 오차 허용범위의 개발에 대한 연구)

  • Chang, Sang-Wu;Kim, Nam-Yong;Choi, Ho-Sung;Kim, Yong-Whan;Chu, Kyung-Bok;Jung, Hae-Jin;Park, Byong-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.65-70
    • /
    • 2005
  • Those specifications of the CLIA analytical tolerance limits are consistent with the performance goals in Six Sigma Quality Management. Six sigma analysis determines performance quality from bias and precision statistics. It also shows if the method meets the criteria for the six sigma performance. Performance standards calculates allowable total error from several different criteria. Six sigma means six standard deviations from the target value or mean value and about 3.4 failures per million opportunities for failure. Sigma Quality Level is an indicator of process centering and process variation total error allowable. Tolerance specification is replaced by a Total Error specification, which is a common form of a quality specification for a laboratory test. The CLIA criteria for acceptable performance in proficiency testing events are given in the form of an allowable total error, TEa. Thus there is a published list of TEa specifications for regulated analytes. In terms of TEa, Six Sigma Quality Management sets a precision goal of TEa/6 and an accuracy goal of 1.5 (TEa/6). This concept is based on the proficiency testing specification of target value +/-3s, TEa from reference intervals, biological variation, and peer group median mean surveys. We have found rules to calculate as a fraction of a reference interval and peer group median mean surveys. We studied to develop total error allowable from peer group survey results and CLIA 88 rules in US on 19 items TP, ALB, T.B, ALP, AST, ALT, CL, LD, K, Na, CRE, BUN, T.C, GLU, GGT, CA, phosphorus, UA, TG tests in chematology were follows. Sigma level versus TEa from peer group median mean CV of each item by group mean were assessed by process performance, fitting within six sigma tolerance limits were TP ($6.1{\delta}$/9.3%), ALB ($6.9{\delta}$/11.3%), T.B ($3.4{\delta}$/25.6%), ALP ($6.8{\delta}$/31.5%), AST ($4.5{\delta}$/16.8%), ALT ($1.6{\delta}$/19.3%), CL ($4.6{\delta}$/8.4%), LD ($11.5{\delta}$/20.07%), K ($2.5{\delta}$/0.39mmol/L), Na ($3.6{\delta}$/6.87mmol/L), CRE ($9.9{\delta}$/21.8%), BUN ($4.3{\delta}$/13.3%), UA ($5.9{\delta}$/11.5%), T.C ($2.2{\delta}$/10.7%), GLU ($4.8{\delta}$/10.2%), GGT ($7.5{\delta}$/27.3%), CA ($5.5{\delta}$/0.87mmol/L), IP ($8.5{\delta}$/13.17%), TG ($9.6{\delta}$/17.7%). Peer group survey median CV in Korean External Assessment greater than CLIA criteria were CL (8.45%/5%), BUN (13.3%/9%), CRE (21.8%/15%), T.B (25.6%/20%), and Na (6.87mmol/L/4mmol/L). Peer group survey median CV less than it were as TP (9.3%/10%), AST (16.8%/20%), ALT (19.3%/20%), K (0.39mmol/L/0.5mmol/L), UA (11.5%/17%), Ca (0.87mg/dL1mg/L), TG (17.7%/25%). TEa in 17 items were same one in 14 items with 82.35%. We found out the truth on increasing sigma level due to increased total error allowable, and were sure that the goal of setting total error allowable would affect the evaluation of sigma metrics in the process, if sustaining the same process.

  • PDF