• Title/Summary/Keyword: External Noise

Search Result 668, Processing Time 0.026 seconds

Design and Evaluation of Noise Suppressing Hydrophone

  • Im, Jong-in
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.546-560
    • /
    • 2000
  • This paper describes the design and evaluation of a noise suppressing hydrophone that is robust to external noise without sacrificing its performance as a receiver. To increase robustness of the receiver to the external noise, first, effects of location of external noise on its performance are analyzed with the finite element method (FEM). Based on the results, geometrical variations are implemented on the structure with additional air pockets and damping layers that work as acoustic shields or scatterers of the noise, and fourteen trial models are developed for the noise suppressing hydrophone structures. The results show that the effect of the external noise is most significant when it is applied to near the mid-side surface of the hydrophone housing. The external noise is isolated most efficiently when two thin damping layers combined with five air pockets are inserted to the circumference of the hydrophone housing. Overall, of the fourteen structural variations of the hydrophone, the best one shows about 87% reduction in the response of the original structure to external noise.

  • PDF

A Study on External Light Noise Reduction Using Stereo Vision System in Image Monitoring System (스테레오비전시스템을 이용한 실내 영상감시시스템의 외란광 간섭 경감에 관한 연구)

  • Kim, Soo-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.83-90
    • /
    • 2009
  • In this paper, a method for reduction of error ratio by external light noise is proposed, which separates error moving component caused by external light noise from moving component of an object, using depth information of stereo image. If measured depth information change of extracted moving component is insignificant, the moving component is considered as external light noise, which concludes that there is no moving object. Experimental results assert the usefulness of the proposed method which makes error ratios by external light noise and by false image as shadow diminish.

A Subjective Evaluation on the Noise Environment of the Low - rise Multifamily House of Korean lived in Athens, America (미국거주 한국인의 저층 공동주택 소음 환경에 대한 주관적 평가 - Athens시 중심으로 -)

  • 곽경숙
    • Journal of the Korean housing association
    • /
    • v.10 no.2
    • /
    • pp.203-212
    • /
    • 1999
  • The purpose of this study is to evaluate the Korean residents' subjective opinion of the noise on the lowrise multifamily house in America. The results of this study can be applied for the prevention of noise when planning cities, roads, and multifamily houses in Korea. The subjects of this study are three kinds of multifamily houses and their 124 Korean residents in Athens, America. The results of this study are as follows. The Korean residents felt the noise from lawn mowers and the sound of filter fan of air conditioners were higher than all the other external noise. They were disturbed a little by the external noise. The air borne sound was recognized a little by Korean residents but they only felt moderate sound of building services and household equipment from the solid borne sound of the internal noise. They suffered worse from external noise in the summer and they felt worse from 8~12 o'clock due to external noise and 20~24 o'clock due to internal noise. The Korean residents liked the sound of birds or insects, the sound of cars and trains. However many Korean people in Athens disliked the sounds of birds or insects and lawn mowers more than these sounds in Korea. The Korean residents who were living in the apartment houses felt better than those in the other multifamily houses.

  • PDF

A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS (GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구)

  • Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

The Evaluation on the Noise Environment of the Low-rise Multi-family house in Athens,U,S,A (미국 Athens 지역 저층 공동주택 소음 환경평가에 관한 연구)

  • 곽경숙
    • Journal of the Korean housing association
    • /
    • v.11 no.4
    • /
    • pp.85-96
    • /
    • 2000
  • The purpose of this study was to evaluated noise environment of the low-rise multi-family house in Athens, Georgia. The results of this study can be applied to the prevention of noise when planning multi-family houses, roads and cities in Korea. The subjects of this study were the place of 1m, 10m, 50m, 100m from 4-lane road ofT apartment and 233 residents lived in the low-rise multi-family houses in Athens. The results of this study were as follows. 1. The average noise level at 1m, 10m, 50m and 100m was 55.5dB, 46.7dB, 43.0dB, 43.0dB and 41.2dB respectively from 4-lane road of T apartment. From the view of the standard in this study, the physical noise was good. 2. The results of the residents subjective response on the noise were as follows. The external noise residents felt - that was a noise by operating machines, and traffic noise - ware as 2.57 on average. The noise by the daily activities, the noise of nature are a little as 2.38 on average. They were disturbed a little by the external noise. They felt the solid born sounds(average 2.49) more than airbone sound(average 2.23) by the internal noise. They are suffered worse from noise in summer and they worse from 8-12 oclock due to external noise and 16-20 oclock due to internal noise. Comparing the noise environment of Korean with that of American, I found a meaningful difference of nature and the noise of daily activities of external noise and all internal noise.

  • PDF

A Study on the Noise Reduction through the Control of Internal Flow for a Slim Type External ODD (슬림타입 외장형 ODD 내부의 유동 안정을 통한 소음저감에 관한 연구)

  • Lee, Woo-Jin;Seo, Jun-Ho;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.2
    • /
    • pp.72-77
    • /
    • 2012
  • The demand for the laptop computer has been increased day by day and most of users ask quiet computer and devices to work in comfortable environment. One of the devices which generate acoustic noise is an external ODD. Unlike the internal ODD, the external ODD is easy to emit noise because it runs outside of the computer and also it is packed with a thin plastic covers. As the disk rotates, vortex flow is generated inside of the cavity due to various and complicated mold parts of the cover. In addition, there is a gap between the disk tray and the upper/lower cases, through which the air flows as well as the noise leaks. In this study, we have proposed how to reduce the acoustic noise of an external ODD using numerical and experimental analysis. The pressure fluctuations and turbulent kinetic energy distributions are calculated for the developed model. The results show that the sound pressure level is reduced by 2.3dB through simple modifications of ribs of the top cover, which remove or suppress flow instabilities inside of the cavity.

External Noise Analysis Algorithm based on FCM Clustering for Nonlinear Maneuvering Target (FCM 클러스터링 기반 비선형 기동표적의 외란분석 알고리즘)

  • Son, Hyun-Seung;Park, Jin-Bae;Joo, Young-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2346-2351
    • /
    • 2011
  • This paper presents the intelligent external noise analysis method for nonlinear maneuvering target. After recognizing maneuvering pattern of the target by the proposed method, we track the state of the target. The external noise can be divided into mere noise and acceleration using only the measurement. divided noise passes through the filtering step and acceleration is punched into dynamic model to compensate expected states. The acceleration is the most deterministic factor to the maneuvering. By dividing, approximating, and compensating the acceleration, we can reduce the tracking error effectively. We use the fuzzy c-means (FCM) clustering as the method to divide external noise. FCM can separate the acceleration from the noise without criteria. It makes the criteria with the data made by measurement at every sampling time. So it can show the adaptive tracking result. The proposed method proceeds the tracking target simultaneously with the learning process. Thus it can apply to the online system. The proposed method shows the remarkable tracking result on the linear and nonlinear maneuvering. Finally, some examples are provided to show the feasibility of the proposed algorithm.

An internal partial discharge measurement method excepted an external corona noise (외부 코로나 노이즈를 제거한 내부 부분방전 측정기법)

  • 권동진;진상범;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.44-50
    • /
    • 2001
  • The largest problem in applying the elecbical partial discharge measurement method the transformer that has been operated until now is the removal of external corona noise In this thesis, a methcd was studied. to rneasme only fue partial discharge sIgnal due to the defoct in transfonrer except the external corona noise. To find out the types of partial discharge and corona noise within a transfomr, a partial discharge was made in use of a needle-plane electrodes within a model transfonner and, at the same time, an external corona noise was generated in use of a rod-sphere electrcdes in the air around the transformer. Both of a partial clischarge signal caused from an intemat defect within a transformer and an external noise were found at the rogowski coil which was located at transformer earth wire. When the external corona noise, which was separately measured in use of an antenna sensor out of transfonner, was removed from the signal measured on rogowski coil, the signal caused by partial discharge within a transformer would effectively be acquired.quired.

  • PDF

Investigation of Source Modelling for External Noise Prediction of Railway Vehicles (철도차량 외부소음 예측을 위한 음원모델에 관한 고찰)

  • Kim, Jong-Nyeun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1069-1077
    • /
    • 2009
  • For external noise prediction of railway vehicles, sophisticated individual source modelling as well as appropriate noise propagation model from the sources is necessary to ensure the accuracy of the predicted results and contributions of each equipment to the overall noise levels. Accurate and reasonable identification procedures of sound sources of equipment including source strength, directivity and positions installed in the train play an important role in a prediction model, since it is not easy to establish a simple model for the sources with a single rule due to the complexity of source characteristics of equipment in size and directivity pattern. This paper guidelines practical considerations for identification of noise sources in railway vehicles including typical source characteristics of several sub-systems that emits noise to the environment, particularly for electric multiple unit(EMU), and verify effectiveness of assumptions used in the modelling of equipment by measurement with a simple part. The predicted external noise level of a complete train using Exnoise, which was developed by Hyundai-Rotem and has been verified in the a lot of field-tests, incorporating source modelling considered in this paper shows close correlation with the measured ones.

  • PDF

A Subjective Evaluation on the Noise Environment of the Low-rise Multifamily House in Athens, U. S. A (미국 저층 공동주택 거주자의 소음 환경에 대한 주관적 평가 - Athens시를 중심으로 -)

  • 곽경숙
    • Korean Journal of Human Ecology
    • /
    • v.1 no.2
    • /
    • pp.61-74
    • /
    • 1998
  • The purpose of this study is to investigate residents subjective opinion of the noise on the low-rise multifamily house in U.S.A. The results of this study can be applied for the prevention of noise when planning cities, roads, and multifamily houses in Korea. The subjects of this study are three kinds of multifamily houses and their 109 residents in Athens, U.S.A. The results of this study are as follows. The residents felt the noise from lawn mowers and the sound from filter fans of air conditioners were higher than in the other external noise. The residents daily activities were disturbed a little by the external noise. Of the internal noise, the air home sound was recognized a little by residents. They only felt a moderate sound level from the building services of the solid borne sound. They suffered worse from noise in the summer and they felt worse from 16∼20 o'clock due to noise. The residents who were living in town houses felt better than those in the other multifamily houses. (Korean J Human Ecology 1(2):61∼74. 1998)

  • PDF