• Title/Summary/Keyword: External Excitation

Search Result 214, Processing Time 0.022 seconds

Charicteristics of HF 10-cm Type Grid Ion Source for Inert and Chemically Reactive Gases.

  • Chol, W.K;Koh, S.K;Jang, H.G;Jung, H.J;Kondranin, S.G.;Kralkina, E.A.;Bougrov, G.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1996.02a
    • /
    • pp.102-102
    • /
    • 1996
  • This paper represents a new type low power High Frequency technological ion source (HF TIS) for ion - beam processing: the surface modification of materials, cleaning of surface, sputtering, coating of thin films, and polishing. The operational principle of HF TIS is based on the excitation of electrostatic waves in plasma located in the external magnetic field. Low power HF TIS with diameter 92 rom gives the opportunity to obtain beams of inert and chemically reactive gases with currents range from 5 to 150 mA (current density $0.015\;~\;3.5\;mA/\textrm{m}^2$) and ion beam energy 100 ~ 2500 eV at a HF power level 10 ~ 150 W. Three grid concave type ion optical system (IOS) is used for extraction and formation ofion beam.n beam.

  • PDF

An Intelligent Power Transformer Protective Relaying Algorithm Based on Furzy Decision-Making (Fuzzy Decision-Making을 이용한 지능형 변압기 보호 계전 알고리즘)

  • Lee, S.J.;Kang, S.H.;Choe, Myeon-Song;Kim, S.T.;Kang, D.H.;Kim, K.H.;Kim, I.D.;Jang, B.T.;Lim, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.891-893
    • /
    • 1997
  • In this paper an intelligent power transformer protective relaying algorithm based on Fuzzy Decision-Making is presented. The introduced protection algorithm contains several internal fuzzy rule-bases including bpa(Basic Probability Assignment: m) which are subject to off-line pre-installation by the analysis of the transformer transient characteristics for detecting the internal fault. Dempster-Shafer's rule of combination is used for the inference method with rules to decide the situation of a transformer, The proposed algorithm immunes to the saturation of transformer, inrush conditions, over excitation, and external fault. The included results of testing show practically sufficient sensitivity and selectivity of the proposed algorithm.

  • PDF

Generalization of the statistical moment-based damage detection method

  • Zhang, J.;Xu, Y.L.;Xia, Y.;Li, J.
    • Structural Engineering and Mechanics
    • /
    • v.38 no.6
    • /
    • pp.715-732
    • /
    • 2011
  • A novel structural damage detection method with a new damage index has been recently proposed by the authors based on the statistical moments of dynamic responses of shear building structures subject to white noise ground motion. The statistical moment-based damage detection (SMBDD) method is theoretically extended in this paper with general application. The generalized SMBDD method is more versatile and can identify damage locations and damage severities of many types of building structures under various external excitations. In particular, the incomplete measurements can be considered by the proposed method without mode shape expansion or model reduction. Various damage scenarios of two general forms of building structures with incomplete measurements are investigated in consideration of different excitations. The effects of measurement noise are also investigated. The damage locations and damage severities are correctly identified even when a high noise level of 15% and incomplete measurements are considered. The effectiveness and versatility of the generalized SMBDD method are demonstrated.

Comparison of piezoelectric flextentional sonar transducer simulations between a coupled FE-BEM and ATILA code (결합형 유한요소-경계요소 기법과 ATILA와의 압전체 유연성 쏘나 변환기 시뮬레이션 비교)

  • Soon-Suck Jarng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.559-567
    • /
    • 1999
  • A piezoelectric flextentional sonar transducer has been simulated using a coupled FE-BEM. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with external electrical excitation conditions. Different results are available such as steady-state displacement modes, underwater directivity patterns, resonant frequencies, bandwidths, quality factors, output acoustic powers and transmitting voltage responses. It is shown that the present barrel-stave sonar transducer of the piezoelectric material produces flextentional displacements which could be related with higher output power, lower quality factor and more omnidirectional beam pattern than other types of sonar transducers. The results of the present sonar transducer modelling are also compared with those of a commercial package such as ATILA.

  • PDF

An Investigation into the Mode Superposition Method for the Foreced Transverse Vibration Analysis of Structures subject to the Timoshenko Beam Analogy (기준진동형중첩법(基準振動型重疊法)에 의한 Timoshenko보 유추(類推) 구조체(構造體)의 강제횡진동해석(强制橫振動解析))

  • K.C.,Kim;Y.I.,Park;H.M.,Kim;Y.J.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.20 no.1
    • /
    • pp.21-27
    • /
    • 1983
  • The mode superposition method(MSM) for the forced transverse vibration analysis of structures subject to Timoshenko beam analogy, which had originally been developed by Ormondroyd and McGoldrick, is reviewed to formulate it in more general form taking account of rotary inertia, dampings in separate terms of internal and external ones, and simultaneous action of exciting forces and moments. To investigate some general features of the method in practical utilizations, resonant maximum amplitudes of 4 high speed ships under concentrated sinusoidal excitation at the stern are calculated by both MSM and the finite difference method(FDM). For the FDM the hulls are discretized into 40 equal segments, and in utilization of MSM contributions of the first six modes are summed up to obtain responses up to the six-nodes resonant mode. The numerical results show that MSM gives slightly higher values, $4{\sim}10%$, than those by FDM. Since there is always uncertainty in the damping estimation of actual systems, influences of the damping magnitude on resonant amplitudes and a practical method to estimate modal damping coefficients are discussed.

  • PDF

Refined optimal passive control of buffeting-induced wind loading of a suspension bridge

  • Domaneschi, M.;Martinelli, L.
    • Wind and Structures
    • /
    • v.18 no.1
    • /
    • pp.1-20
    • /
    • 2014
  • Modern design of long suspension bridges must satisfy at the same time spanning very long distances and limiting their response against several external loads, even if of high intensity. Structural Control, with the solutions it provides, can offer a reliable contribution to limit internal forces and deformations in structural elements when extreme events occur. This positive aspect is very interesting when the dimensions of the structure are large. Herein, an updated numerical model of an existing suspension bridge is developed in a commercial finite element work frame, starting from original data. This model is used to reevaluate an optimization procedure for a passive control strategy, already proven effective with a simplified model of the buffeting wind forces. Such optimization procedure, previously implemented with a quasi-steady model of the buffeting excitation, is here reevaluated adopting a more refined version of the wind-structure interaction forces in which wind actions are applied on the towers and the cables considering drag forces only. For the deck a more refined formulation, based on the use of indicial functions, is adopted to reflect coupling with the bridge orientation and motion. It is shown that there is no variation of the previously identified optimal passive configuration.

Dynamic response analysis of vertical pumps (입형펌프의 동적 응답해석)

  • 양보석;김원철;임우섭;권명래
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.362-372
    • /
    • 1989
  • It is important in design of vertical pumps to consider external excitation in addition to rotor vibration due to unbalance. In this study, a model of a vertical pump was developed for the analysis of its dynamic response. The vertical pump was modeled with lumped masses and springs which represent multi-cylindrical and rotor structure. A dynamic simulation program was developed and numerical calculation on the above mentioned problems were carried out.

The Response of the Burke-Schumann Flame to External Excitation with Flame Shape and Heat Release (외부 교란에 대한 Burke-Schumann 화염에서 형상과 열방출량을 통한 응답 특성 파악)

  • Kim, Taesung;Ahn, Myunggeun;Hwang, Jeongjae;Jeong, Chanyeong;Kwon, Oh Chae;Yoon, Youngbin
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.1
    • /
    • pp.32-38
    • /
    • 2017
  • This paper shows the dynamics of the Burke-Schumann flame. To show flame dynamics, this paper measures the flame surface and heat release rate. The flame shape is divided into three types with forcing frequencies. When the forcing frequency is lower than 120 Hz, the upper region of flame is cut. The flame is stagnant with 220 to 280 Hz forcing frequencies. The rest conditions of forcing frequencies make the connected wave shape of flame. The heat release rate is expressed by the flame transfer function. The gain of the flame transfer function is similar with the oscillation magnitude of the flame area except for flame cutting conditions. The flame is cut because the fuel is not supplied to upper flame region.

Efficient Two-Stage Braking Method of Three-Phase Induction Motor (3상 유도전동기의 효율적인 2단 제동 기법)

  • Lee, Eun-Young;Kim, Yong;Kim, Pill-Soo;Kwon, Soon-Do
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.29-36
    • /
    • 1998
  • In this paper, two-stage braking method of 3-phase induction motrois proposed. This brake involves tow stages. The first stage is capacitor self-excitation braking, and the second stage is three-phase magnetic braking. In several applicatons, a low cost and effective brake is required for three-phase induction motor. A mechanical friction brake, typical braking method for induction motor requires external energy sources which is not safe, expensive and requires maintenance. Static and dynamic analyses of the proposed brake scheme are along with analytical result, simulated waveforms and experimental waveforms are compared. The experimental results shows good agreement with the simulated results.

  • PDF

The active vibration control with force cancelling observer in elastic system (힘 상쇄 관측기를 이용한 탄성계 진동의 능동제어)

  • 박영필;이규섭;최봉환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1016-1025
    • /
    • 1988
  • A force cancelling observed to control the vibration of a single degree of freedom elastic system subjected to an arbitrary, unmeasurable disturbance is considered in this paper. The main idea of a force cancelling observer is how an estimate of the excitation can be derived and used to generate a control force which reduces the vibration. This control is shown to be robust with respect to the parameters describing the behavior of the system. Experimental and numerical results are presented which show the efficacy of the observer when the system is excited by periodic, random, and impulsive torques.