• 제목/요약/키워드: Exterior Environment

검색결과 308건 처리시간 0.02초

해체주의 건축 디자인에서 설치미술과의 상관성에 관한 연구 (A Study on the Relationship to Installation Art in Deconstruction Architecture Design)

  • 김명옥
    • 한국실내디자인학회논문집
    • /
    • 제12호
    • /
    • pp.10-17
    • /
    • 1997
  • The lastest art is being characterised by an ever active exchange between different genre. This is a study on the installation aspect in deconstruction architectured and interior design. The progressive and aggressive nature of installatation art embodies uncatagorized genre, the freedom of material application, introduction of the notion of time in space, the reversion of subject and object, the union of art and every experience, understanding of object through deconstruction, enlargement of concept of space, collage-style composition and layer technique. I can conclude that the installation aspect in Tshumi's Parc de la Villette is its call upon the audience to actively participate, the introduction of a coincidental conjunction, its challenge on the conventional idea of park and its flexibility caused by human activity and time. In Hadid's Hong Kong Peak Club the installation aspect is the application of layer technique using four enormous beams horizontally laid out on a man-made moutain. Furthermore, Libeskind's pursuit of the mental in Berlin Museum Extension through the penetration of an invisible line into a void creates a new interpretation of the role of a museum and thus relates itself to installation art. The installation aspect in Himmelblau's Vienna Roof Renovation is the literal deconstruction of the roof of an old building in the old section of Wien and the expression of time and space through the interrelationship between interior and exterior environment by the use of juxtaposition technique. Finally, I note that the installation aspect in Gehry's Santa Monica Residence is the reorganization of cheap material as a form of 'object', that creates spon-taneity, movement as well as flow of time in space and ex-hibit the double-sidedness of the visible world.

  • PDF

총채널 불확실도를 적용한 원전 노심출구온도의 운전가능 판정기준 (Operating Criteria of Core Exit Temperature in Nuclear Power Plant with using Channel Statistical Allowance)

  • 성제중;윤덕주;하상준
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.166-171
    • /
    • 2014
  • Nuclear power plants are equipped with the reactor trip system (RTS) and the engineered safety features actuation system (ESFAS) to improve safety on the normal operation. In the event of the design basis accident (DBA), a various of post accident monitor(PAM)systems support to provide important details (e.g. Containment pressure, temperature and pressure of reactor cooling system and core exit temperature) to determine action of main control room (MCR). Operator should be immediately activated for the accident mitigation with the information. Especially, core exit temperature is a critical parameter because the operating mode converts from normal mode to emergency mode when the temperature of core exit reaches $649^{\circ}C$. In this study, uncertainty which was caused by exterior environment, characteristic of thermocouple/connector and accuracy of calibrator/indicator was evaluated in accordance with ANSI-ISA 67.04. The square root of the sum of square (SRSS) methodology for combining uncertainty terms that are random and independent was used in the synthesis. Every uncertainty that may exist in the hardware which is used to measure the core exit temperature was conservatively applied and the associative relation between the elements of uncertainty was considered simultaneously. As a result of uncertainty evaluation, the channel statistical allowance (CSA) of single channel of core exit temperature was +1.042%Span. The range of uncertainty, -0.35%Span ($-4.05^{\circ}C$) ~ +2.08%Span($24.25^{\circ}C$), was obtained as the operating criteria of core exit temperature.

엔지니어링 플라스틱의 LED조명 방열판 적용 (Heat Sink of LED Lights Using Engineering Plastics)

  • 조영태
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.61-68
    • /
    • 2013
  • As an advance study for the development of a heat sink for special purpose high power illumination, an investigation was made to find feasibility for the application of copper plated EP to a heat sink of small LED light of less than 10W installed in commercial product. In this study, the plated heat sink with EP copper was fabricated for the conventional LED light. It was used actually for finding heat radiation property and effectiveness of the heat sink accompanied with measurement of luminous intensity. The heat is radiated by transfer and dissipation only through the copper plated surface due to extremely low heat conductivity of EP in case of EP heat sink; however the total area of the plate plays the function of heat transfer as well as heat radiation in case of the aluminum heat sink. It seems that the volume difference of heat radiating material is so big that the temperature $P_1$ is 9.0~12.3% higher in 3W and 42.7~54.0% higher in case of 6W volume difference of heat radiating material is so big that the temperature $P_1$ is 9.0~12.3% higher in 3W and 42.7~54.0% higher in case of 6W even though heat transfer rate of copper is approximately 1.9 times higher than that of aluminum. It was thought that this is useful to utilize for heat sink for low power LED light with the low heating rate. Also, the illumination could be greatly influenced by the surrounding temperature of the place where it is installed. Therefore, it seems that the illumination installation environment must be taken into consideration when selecting illumination. Further study was expected on order to aims at development of an exterior surface itself made into heat radiation plate by application of this technology in future.

지역성 구현을 위한 집합주택 원형 주거동의 표현 특성 연구 (A Study on the Circular Multi-Family Housing for Designing Local Identity)

  • 문은미
    • 한국실내디자인학회논문집
    • /
    • 제22권4호
    • /
    • pp.121-129
    • /
    • 2013
  • This study was aimed at determining the characteristics of circular multi-family housing under the assumption that the shape of a residential building affects local identity. A total of six case studies were included in this study, three case studies on idle historical industrial facilities turned into residential buildings and another three on multi-family housing located in newly developed residential complexes. The study drew its conclusions as follows. First, the design of circular multi-family housing was intended to maximize security and defense from the outside in older times. This was later developed as the terrace house style with geometric urban squares designed under the urban planning of the Baroque period. This evolved high-density housing with a courtyard in the center offering a green open space, with the aim of restoring a sense of humanity. Second, the six case studies on circular multi-family housing were analyzed from the viewpoint of each factor of local identity, including historical and cultural, landscape, and community. Third, the historical and cultural elements of circular multi-family housing are found in some unused historical industrial facilities remodeled into residential buildings. They provide new capabilities and shapes desired by society at a given time, while maintaining familiar styles and elements of history, integrating a legacy of the past into the present. Fourth, circular multi-family housing with unique shapes and structures often become landmarks of a region with their distinctive appearance against a uniform urban environment and the monotonous scenery of residential complexes. They also show a high level of visual awareness with the distinctive shapes made possible when new elements are added to a historical exterior. Finally, circular multi-family housing with courtyards in the center prompt social contact between inhabitants, especially with dormitories and rental houses for the low-income bracket, which provide a small individual units with high use common space. Circular multi-family housing are planned in a manner similar to a small village or a city. They are designed to enhance sense of community, allocating various public amenities and provide cultural and commercial spaces on the ground floor and courtyard areas.

Experiments on reinforced concrete beam-column joints under cyclic loads and evaluating their response by nonlinear static pushover analysis

  • Sharma, Akanshu;Reddy, G.R.;Eligehausen, Rolf;Vaze, K.K.;Ghosh, A.K.;Kushwaha, H.S.
    • Structural Engineering and Mechanics
    • /
    • 제35권1호
    • /
    • pp.99-117
    • /
    • 2010
  • Beam-column joints are the key structural elements, which dictate the behavior of structures subjected to earthquake loading. Though large experimental work has been conducted in the past, still various issues regarding the post-yield behavior, ductility and failure modes of the joints make it a highly important research topic. This paper presents experimental results obtained for eight beam-column joints of different sizes and configuration under cyclic loads along with the analytical evaluation of their response using a simple and effective analytical procedure based on nonlinear static pushover analysis. It is shown that even the simplified analysis can predict, to a good extent, the behavior of the joints by giving the important information on both strength and ductility of the joints and can even be used for prediction of failure modes. The results for four interior and four exterior joints are presented. One confined and one unconfined joint for each configuration were tested and analyzed. The experimental and analytical results are presented in the form of load-deflection. Analytical plots are compared with envelope of experimentally obtained hysteretic loops for the joints. The behavior of various joints under cyclic loads is carefully examined and presented. It is also shown that the procedure described can be effectively utilized to analytically gather the information on behavior of joints.

일회용 마스터 키 개념을 이용한 다중 방화벽 동적 통과 메커니즘 연구 (Study on the mechanism for the dynamic traversing of multiple firewalls using the concept of one-time master key)

  • 박형우;김상완;이종숙;장행진
    • 컴퓨터교육학회논문지
    • /
    • 제13권5호
    • /
    • pp.103-110
    • /
    • 2010
  • 그리드/클라우드 컴퓨팅 플랫폼에 외부 기관의 컴퓨팅 자원이 잠시 참여하려면 관련된 모든 방화벽 마다 필터링 규칙을 추가하여야 한다. 따라서 인터넷 응용 플랫폼이 점차 그리드/클라우드 환경으로 진화될수록 다중 방화벽을 동적으로 한 번에 통과하기 위한 연구 필요성이 증대한다. 본 논문에서는 방화벽들마다 필터링 규칙을 추가/삭제하기와 같은 기존의 네트워킹 자물쇠 관리 방식에서 일회용 네트워킹 마스터 키를 사용자가 생성하는 방식으로 전환하는 새로운 다중 방화벽 동적 통과 메커니즘을 제시한다. 여기서 마스터 키는 시스템에서 자동 생성되었던 IP 주소, 포트 번호, 시퀀스 번호 등을 일종의 일회용 패스워드 형태로 네트워킹 상대방과 사전 교환을 통한 후 서로 로컬 방화벽들을 상대방에게 열어주는 키로 활용한다. 따라서 제안된 메커니즘은 단대단 사용자 사이의 방화벽의 종류와 숫자에 관계없이 동적으로 방화벽을 통과할 수 있게 한다.

  • PDF

해상컨테이너를 이용한 대학생기숙사 거주 활용 계획 연구 - 암스테르담 대학생기숙사 키트보넨 사례를 중심으로 - (The Planning of Schematic Design for Student Housing Using Shipping Containers - Focused on the Student Housing of Keetwonen -)

  • 이종찬;강윤도;김병선
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.59-64
    • /
    • 2014
  • The purpose of this study was suggested to establish of student housing by using shipping container. The research method are a study of shipping container and characteristics of student housing by using shipping container, compared typically student housing with student housing by using shipping container. Also there are planning though a case study of various planes and survey based on the student housing city in Amsterdam, Netherland, is called Keetwonen. It is a planning for housing unit to actual build at the part of land to devise master plan The 40FT(High Cube) Shipping Container housing unit are double occupancy room with toilet and balcony. The common areas are the kitchen, laundry facilities, conference room and lounge are available on the first floor with a lightweight steel frame construction method applied for obtain substantive utilization of the space. Considering into the type and scale of site shall be planning in the form of side corridor and central corridor, which is preferable to separate the interior space into two areas by a central corridor to secure personal privacy. Also, planning such as a separate exterior panel, color and landscape design to improve the external image of the container and block the solar radiation heat influx with a pitched roof. Allow 24 college students shall live at the site of Seongnae-dong, Gangdong-gu in Seoul, Korea (site area $330.9m^2$), including common facilities and a lounge with a building that has three stories above ground were established to build plans to target the actual land.

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

고발포 소화약제의 온도 변화에 따른 최적발포성능 유지를 위한 자동혼합시스템 개발 (Development of Auto Mixing System of High Expansion Foam for Optimal Expansion Performance according to Changing Temperature)

  • 김하영;김성수;이동호
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.139-144
    • /
    • 2010
  • 기계포소화약제는 다량의 물에 포소화약제 원액을 녹인 포수용액을 발포기에 의하여 기계적인 수단으로 공기와 혼합 교반하여 거품을 발생시키는 약제를 말한다. 다양한 설비(이동식, 고정자동식) 적용성, 대형의 유류화재 적합, 대량.연속 생산이 가능한 약제의 특수성 및 장기보관이 가능한 특징이 있어 이에 대한 개발 및 연구가 꾸준히 진행되고 있다. 그러나 이러한 포소화약제는 주변의 온도 및 운용조건에 따라 발포력의 변화가 큰 특징이 있어 실제 겨울철 소방 활동시에는 사용을 자제하고 있다. 본 연구에서는 소화활동시 온도가 발포력에 미치는 영향을 분석하고 이를 활용하여 소방차에 적용 가능한 시스템을 개발하였다. 결과로 기준 약제 혼합비인 3.0%일 경우 온도차에 따라 최대 30.08%의 발포성능차가 발생하는 것으로 분석되었다. 또한 자동 혼합 시스템의 적용성을 분석한 결과 설계값과 실제실험값의 오차가 최대 0.012%로 나타남에 따라 해당 시스템의 적용성이 확보된 것으로 판단되었다.

디젤오염토양의 Bench Scale 처리에 있어서 벤팅모드 비교 (Comparison of Venting Modes for Bench Scale Treatment of Diesel Contaminated Soil)

  • 김영암;이용희;이동선;서명교
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.499-505
    • /
    • 2006
  • Bioventing efficiency was compared in a continuous and an intermittent(6hr injection and 6hr rest) air injection mode. Two lab-scale columns which packed with 5 kg of soil artificially contaminated by diesel oil were operated. The columns were maintained at the $25^{\circ}C{\pm}2.5$ in order to minimize the effect of exterior temperature variation. The flow rate of air injection mode were maintained constantly at the flow rate of 10 ml/min. The moisture of the columns was stably maintained at $60{\sim}80%$ of field capacity. The nutrient compounds were added to make C:N:P ratio as 100:10:l. The continuous and intermittent injection modes showed 67.56% and 69.63% reduction of initial TPH concentration during 90 days, respectively. Two venting modes showed similar results in the analysis of the trends of the hydrocarbon utilizing bacterial counts for operating periods. The carbon dioxide production rate of the continuous injection mode was higher than that of intermittent injection mode. The loss of diesel oil by volatilization in the continuous and intermittent injection modes were about 5% and 1%, respectively. The lower volatilization loss in the intermittent injection mode suggested that the biodegradation of TPH in the intermittent injection mode was greater than that of the continuous mode. These results suggested that the intermittent injection mode is more efficient than the continuous venting mode.