• 제목/요약/키워드: Exterior Connection

검색결과 97건 처리시간 0.028초

초등학교(初等學校) 필로티 공간(空間)의 이용실태(利用實態) 및 계획방향(計劃方向)에 관한 연구(硏究) (A Study on Usage Pattern and Plan of the Piloti Space in the Elementary School)

  • 이상호;이상규;김성주;백지원
    • 교육시설
    • /
    • 제7권4호
    • /
    • pp.17-26
    • /
    • 2000
  • The purpose of this study is to suggest how to use the piloti space at a primary school planning which is the critical element of an exterior space. On the process, we define the Piloti function as the connection of exterior spaces and the community and the parking lot. These research data give us helpful ideas to plan a positive exterior space at an elementary school by use of piloti space, in terms of its suitable location and size.

  • PDF

A Genotypical Analysis of Korean REMCs and Generation of Base Line Data for the Analysis and Evaluation for Future (REMCs) Designs Using Space Syntax

  • 울라 우바이드;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권1호
    • /
    • pp.17-28
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze the spatial configurations of a sample of Korean regional emergency medical centers (REMCs) to explore its underlying genotypes and thus produce a base line data for the analysis and evaluations of future REMCs designs using space syntax theory. Methods: Space syntax analysis was used as a major tool for the analysis and exploration of Genotype. The measures of Integration(overall integration with exterior and without exterior as well as the integration of individual clinical spaces for each center), base difference factor (DF) and Space link ratio were calculated for a sample of seven Korean REMCs. Results: The result shows a strikingly similar pattern of Syntactic measures across the sample, the mean integration of sample ranges from 0.82-0.99 with exterior (while considering the exterior space as a root) and 0.81-1.01 without exterior (considering the connections of interior spaces only with no outside connection). The base difference factor (DF) of the sample varies from 0.60-0.81 with exterior and from 0.59-0.82 without exterior. Case number-1 was identified as non-genotype with differing order of Syntactic values. Although the genotype had different forms, layouts and even sizes, these results cannot be explained by Phenotypical comparisons. Implications: This study will contribute to the configurational analysis and evaluation of existing and future Korean REMCs design and practice of emergency healthcare delivery system in Korea.

수직적 도시 공동주거 커뮤니티에 적용된 공유공간의 계획특성 연구 -단위세대 경계부와 주거동 내부 및 경계부 영역을 중심으로- (A Study on the Design Characteristics of Communal Spaces in Vertical Urban Multi-Family Housing Community -Focused on the Territories of a Unit Boundary, Building Interior and Exterior Boundary-)

  • 조민정
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.55-67
    • /
    • 2011
  • The purpose of this research is to find applicable design characteristics and methods of communal spaces in vertical urban multi-family housing. With this goal, several overseas' multi-family housing projects are selected and their communal spaces are identified. The design characteristics of the communal spaces are analyzed with a special focus on the territories such as an individual unit boundary, building interior and exterior boundary. In terms of the framework for analysis, territoriality, openness, and unique characteristics are reviewed. As a result, the communal spaces are created using various spatial composition methods such as addition, subtraction, connection, extension, accumulation, and isolation. The communal space programs are integrated in plans and sections throughout the buildings. Visual openness and connection with surrounding urban environments are articulated by void spaces, transparent and translucent building materials, green spaces, and applications of graphical images. Communal identities and aesthetics are emphasized by unique building forms and space arrangements. The uses of finish materials, colors, objects, and images add strong characters to the communal spaces. For a further research, it is necessary to combine a design method study with residents' behaviors and community interactions.

Behaviour of bolted connections in concrete-filled steel tubular beam-column joints

  • Beena, Kumari;Naveen, Kwatra;Shruti, Sharma
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.443-456
    • /
    • 2017
  • Many authors have established the usefulness of concrete filled steel tubular (CFST) sections as compression members while few have proved their utility as flexural members. To explore their prospective as part of CFST frame structures, two types of connections using extended end plate and seat angle are proposed for exterior joints of CFST beams and CFST columns. To investigate the performance and failure modes of the proposed bolted connections subjected to static loads, an experimental program has been executed involving ten specimens of exterior beam-to-column joints subjected to monotonically increasing load applied at the tip of beam, the performance is appraised in terms of load deformation behaviour of joints. The test parameters varied are the beam section type, type and diameter of bolts. To validate the experimental behaviour of the proposed connections in CFST beam-column joints, finite element analysis for the applied load has been performed using software ATENA-3D and the results of the proposed models are compared with experimental results. The experimental results obtained agree that the proposed CFST beam-column connections perform in a semi-rigid and partial strength mode as per specification of EC3.

외부마감재가 부착된 볼트접합 방식 패널링 시스템의 내진성능평가를 위한 진동대 실험 (Shake Table Test on Seismic Performance Evaluation of the Bolted Connection Type Paneling System with Exterior Finish Material)

  • 오상훈;박종원;박해용
    • 한국지진공학회논문집
    • /
    • 제22권1호
    • /
    • pp.23-32
    • /
    • 2018
  • In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.

Experimental and numerical assessment of beam-column connection in steel moment-resisting frames with built-up double-I column

  • Dehghan, Seyed Mehdi;Najafgholipour, Mohammad Amir;Ziarati, Seyed Mohsen;Mehrpour, Mohammad Reza
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.315-328
    • /
    • 2018
  • Built-up Double-I (BD-I) columns consist of two hot rolled IPE sections and two cover plates which are welded by fillet welds. In Iran, this type of column is commonly used in braced frames with simple connections and sometimes in low-rise Moment Resisting Frames (MRF) with Welded Flange Plate (WFP) beam-column detailing. To evaluate the seismic performance of WFP connection of I-beam to BD-I column, traditional and modified exterior MRF connections were tested subjected to cyclic prescribed loading of AISC. Test results indicate that the traditional connection does not achieve the intended behavior while the modified connection can moderately meet the requirements of MRF connection. The numerical models of the connections were developed in ABAQUS finite element software and validated with the test results. For this purpose, moment-rotation curves and failure modes of the tested connections were compared with the simulation results. Moreover to avoid improper failure modes, some improvements of the connections were evaluated through a numerical study.

레퍼토리 그리드 발전 수법을 적용한 건축물 외관 디자인 평가에 관한 연구 - 소규모 전시 건축물을 중심으로 - (A Study on the Evaluation of Building Exterior Design Applied to Repertory Grid Developmental Method - Focused on Small Exhibition Buildings -)

  • 윤갑근;정사희;이종영
    • 한국실내디자인학회논문집
    • /
    • 제26호
    • /
    • pp.26-34
    • /
    • 2001
  • The problems with the small exhibition buildings such a small gallery and art center recently constructed did not make the characteristics of the place specifying and did not form a big flow in the line of urban connection. Also it was deficient in the image like a cultural space because of the commercial aspects of the individual buildings. According to this view, this study is to evaluate the exteriors of the small exhibition buildings that the public prefers on the psychological side as a design theory and then, it is to present the direction of desirable form constitution hereafter. In the design of the small exhibition buildings exterior that the public must prefers, the principles and techniques of constitution that operate are the most initiative as follows. As for the principles of unity in the constitution of the small exhibition buildings exterior that the public prefers, Eigen Value is 7.573 and the explanatory force takes 21.637% at the top and it plays a leading role. In the comparison of the appearance, it shows that it is a factor with the largest specific gravity. The next factors were grouped in good order: the balance, ornamental technique, change, shipping technique, rhythm, harmony, symbolic technique, area technique and adding technique. As a result, in the design of the small exhibition buildings exterior, the architects have to constitute the principles of balance, change, rhythm and harmony by most of the unity and the symbolic technique and form technique by most of the ornamental techniques harmoniously and have to give Identity like exhibition buildings.

  • PDF

CFT 기둥-RC 무량판 슬래브 외부접합부의 횡저항 성능 (Lateral Resisting Capacity for CFT Column to RC Flat Plate Slab Exterior Connections)

  • 송호범;송진규;오상원;김병조
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.61-64
    • /
    • 2008
  • 콘크리트충전 강관기둥(Concrete Filled steel Tube Column)과 RC 무량판 슬래브의 조합은 거푸집을 사용하지 않는다는 것만으로도 초고층 건물의 공기단축에 상당한 영향을 미칠 수 있다. 뿐만 아니라 기둥의 내력 증진으로 인한 기둥 크기의 축소, 그로 인한 공간 활용도의 증가, 층간 소음문제 해결 등 많은 장점이 잠재되어 있다. 하지만 접합부의 성능을 정확히 밝혀내는 것이 우선 이루어져야 하며, 본 논문에서는 기존에 수행된 CFT 기둥-RC 무량판 슬래브의 내부접합부에 대한 중력 실험과 횡하중 실험을 바탕으로 외부접합부에 대한 실물대 실험을 수행하였다. 외부접합부 실험 결과, 내부접합부 실험체에 비하여 동일한 조건에서 설계된 외부접합부 실험체는 최대 모멘트강도가 $50%{\sim}65%$ 감소하였고, 내진밴드가 추가된 CFT-E2 실험체는 BME 실험체에 비하여 20%의 최대모멘트 증진과 탁월한 연성능력, 에너지 흡수능력을 보유한 것으로 나타났다. 또한 CFT-E2는 내진밴드의 사용으로 슬래브의 휨거동 영역이 확장되었으며 모든 실험체가 설계기준에서 요구하는 0.4V$_c$중력하중 하에서 1.5% 횡변 위비를 만족하였다.

  • PDF

Application of ultra-high performance fiber reinforced concrete for retrofitting the damaged exterior reinforced concrete beam-column joints

  • Al-Osta, Mohammed A.;Khan, Muhammad I.;Bahraq, Ashraf A.;Xu, Shi-Yu
    • Earthquakes and Structures
    • /
    • 제19권5호
    • /
    • pp.361-377
    • /
    • 2020
  • In the present research work, the effectiveness and the efficiency of a retrofitting approach using a layer of ultra-high performance fiber reinforced concrete (UHPFRC) jacket for damaged substandard exterior beam-column joints (BCJs) is experimentally investigated. The main objective of this study is to rehabilitate the already damaged BCJs to meet the serviceability requirements without compromising safety. According to the proposed strengthening technique, a chipped surface, lightly brushed with a dry condition was selected for making a successful bond between normal concrete substrate surface (NCSS) and UHPFRC. Then a fresh UHPFRC jacket with a thickness of 30 mm was cast around the damaged specimens. The entire test matrix was comprised of three 1/3 scale damaged exterior BCJs with a different column axial load (CAL). These specimens were repaired with UHPFRC and retested under monotonic loading. Based on the experimental results, repaired specimens showed an excellent performance in terms of their load-displacement response, maximum strength, displacement ductility, initial stiffness, secant stiffness and energy dissipation capacity when compared with the corresponding values registered when these specimens were tested in their virgin state. This rehabilitative intervention not only restored the strength, stiffness, ductility and energy dissipation capacity of severely damaged specimens but also improved their performance.

콘크리트 기둥-강재 보 외부 접합부의 내진성능(II 강도 및 변형) (Seismic Response of Exterior RC Column-to-Steel Beam Connections (II. Strength and Deformation))

  • 조순호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.283-289
    • /
    • 2000
  • The panel shear and bearing strengths determining the seismic resistance of reinforced concrete column-to-steel beam connections are predicted by various methods for four previously tested exterior beam-column joints. The analytical approach to model the joint deformation is also examined. Several analyses incorporating the deformations of panel shear and bearing in the joint are demonstrated using a analyses incorporating the deformations of panel shear and bearing in the joint are demonstrated using a fairly simple connection model in the commercial packages such as Drain2dx and IDARC. The strength prediction results indicated that the ASCE method with the modifcation of the comprssion strut contribution is th most accurate. It is also considered that the analytical model presented including the joint deformation can be used for the overall analysis

  • PDF