• Title/Summary/Keyword: Extended cut sequence

Search Result 5, Processing Time 0.023 seconds

Safety analysis of marine nuclear reactor in severe accident with dynamic fault trees based on cut sequence method

  • Fang Zhao ;Shuliang Zou ;Shoulong Xu ;Junlong Wang;Tao Xu;Dewen Tang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4560-4570
    • /
    • 2022
  • Dynamic fault tree (DFT) and its related research methods have received extensive attention in safety analysis and reliability engineering. DFT can perform reliability modelling for systems with sequential correlation, resource sharing, and cold and hot spare parts. A technical modelling method of DFT is proposed for modelling ship collision accidents and loss-of-coolant accidents (LOCAs). Qualitative and quantitative analyses of DFT were carried out using the cutting sequence (CS)/extended cutting sequence (ECS) method. The results show nine types of dynamic fault failure modes in ship collision accidents, describing the fault propagation process of a dynamic system and reflect the dynamic changes of the entire accident system. The probability of a ship collision accident is 2.378 × 10-9 by using CS. This failure mode cannot be expressed by a combination of basic events within the same event frame after an LOCA occurs in a marine nuclear reactor because the system contains warm spare parts. Therefore, the probability of losing reactor control was calculated as 8.125 × 10-6 using the ECS. Compared with CS, ECS is more efficient considering expression and processing capabilities, and has a significant advantage considering cost.

Experimental Study on Post-tensioned 3-Continuous Span Slabs (포스트텐션된 3연속 스팬 슬래브의 실험연구)

  • 임재형;문정호;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.668-673
    • /
    • 1998
  • The specimen of current study has the same type with the 3-span slabs of Burns et al used in the study by Mojtahedi/Gamble, which laid a ground for the revision of the ACI318-77 code to the ACI 318-83 code. But those specimens was failed prematurely before it reached the ultimate strength which the specimen had. The reason is that bonded reinforcements were cut off where there is no need for the flexural reinforcement. As results. the slabs failed ultimately where the reinforcements was cut off. Thus, the tendon stresses of failure may have been much smaller than the values which culd reach if the bonded reinforcements were extended beyond the theoretical cut off points. On the based on the fact mentioned above. the specimens which had the same conditions as the specimens of Burns et al were used in the current study, but in which the reinforcements were distributed in a sequence for the reinforcements not to be cut anywhere in the 3-span. As a results, it was known that the current ACI code, revised by the result of Mojtahedi/Gamble's study, overestimated the effect of span/depth ratio on the members with high span/depth ratio. Thus it was concluded that the effect of span/depth ratio on the ultimate stress of unbonded tendon regulated by the current ACI code must be reconsidered and reevaluated.

  • PDF

A study on the machinability of SUS304

  • Lim, K.Y.;Yu, K.H.;Seo, N.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.34-41
    • /
    • 1993
  • SUS304 is wellknown as difficult-to-machine materials. It is easy to appear workhardened, and workhardening is one of the causes of groove wear on the tool. In this paper, the author would like to compare the width of flank wear with that of groove wear, and to find whether the groove wear can be used as a criterion of a tool life. The design of the twelve tests provides three levels for each variable (speed: 200m/min, 118m/min, 70m/min; feed: 0.3mm/rev, 0.17mm/rev, 0.1mm/rev; depth of cut: 0.4mm, 0.28mm, 0.2mm). The study of tool-life testing by statistical technique follows usual most scientific sequence. So the tool-life predicting equation is calculated by the method of least squares. The overall adequacy of the model can be verified by the analysis of variance. The results obtained are as follows : 1) When SUS304 is cut in 200(m/min), the width of flank wear is much larger than that of groove wear. 2) In cutting speed 118m/min, flank wear is a little larger than groove wear and in the cutting speed 70m/min, the latter is a little larger so that it is reasonable to determine the tool life according the crierion by groove wear in the low cutting speed (less than 70m/min). 3) Owing to the burr the depth of engagement along the cutting edge is extended toward the shank.

  • PDF

A design of Space Compactor for low overhead in Built-In Self-Test (내장 자체 테스트의 low overhead를 위한 공간 압축기 설계)

  • Jung, Jun-Mo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.9
    • /
    • pp.2378-2387
    • /
    • 1998
  • This thesis proposes a design algorithm of an efficient space response compactor for Built-In Self-Testing of VLSI circuits. The proposed design algorithm of space compactors can be applied independently from the structure of Circuit Cnder Test. There are high hardware overhead cost in conventional space response compactors and the fault coverage is reduced by aliasing which maps faulty circuit's response to fault-free one. However, the proposed method designs space response compactors with reduced hardware overheads and does not reduce the fault coverage comparing to conventional method. Also, the proposed method can be extended to general N -input logic gate and design the most efficient space response L'Ompactors according to the characteristies of output sequence from CUT. The prolxlsed design algorithm is implemented by C language on a SUN SPARC Workstation, and some experiment results of the simulation applied to ISCAS'85 benchmark circuits with pseudo random patterns generated bv LFSR( Linear Feedback Shift Register) show the efficiency and validity of the proposed design algorithm.

  • PDF

Effect of Calvarial Cell Inoculated Onto the Biodegradable Barrier Membrane on the Bone Regeneration (흡수성 차폐막에 접목된 두개관골세포의 골조직 재생에 미치는 영향)

  • Yu, Bu-Young;Lee, Man-Sup;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.483-509
    • /
    • 1999
  • Biodegradable barrier membrane has been demonstrated to have guided bone regeneration capacity on the animal study. The purpose of this study is to evaluate the effects of cultured calvarial cell inoculated on the biodegradable barrier membrane for the regeneration of the artificial bone defect. In this experiment 35 Sprague-Dawley male rats(mean BW 150gm) were used. 30 rats were divided into 3 groups. In group I, defects were covered periosteum without membrane. In group II, defects were repaired using biodegradable barrier membrane. In group III, the defects were repaired using biodegradable barrier membrane seeded with cultured calvarial cell. Every surgical procedure were performed under the general anesthesia by using with intravenous injection of Pentobarbital sodium(30mg/Kg). After anesthesia, 5 rats were sacrificed by decapitation to obtain the calvaria for bone cell culture. Calvarial cells were cultured with Dulbecco's Modified Essential Medium contained with 10% Fetal Bovine Serum under the conventional conditions. The number of cell inoculated on the membrane were $1{\times}10^6$ Cells/ml. The membrane were inserted on the artificial bone defect after 3 days of culture. A single 3-mm diameter full-thickness artificial calvarial defect was made in each animal by using with bone trephine drill. After the every surgical intervention of animal, all of the animals were sacrificed at 1, 2, 3 weeks after surgery by using of perfusion technique. For obtaining histological section, tissues were fixed in 2.5% Glutaraldehyde (0.1M cacodylate buffer, pH 7.2) and Karnovsky's fixative solution, and decalcified with 0.1M disodium ethylene diaminetetraacetate for 3 weeks. Tissue embeding was performed in paraffin and cut parallel to the surface of calvaria. Section in 7${\mu}m$ thickness of tissue was done and stained with Hematoxylin-Eosin. All the specimens were observed under the light microscopy. The following results were obtained. 1 . During the whole period of experiment, fibrous connective tissue was revealed at 1week after surgery which meant rapid soft tissue recovery. The healing rate of defected area into new bone formation of the test group was observed more rapid tendency than other two groups. 2 . The sequence of healing rate of bone defected area was as follows ; test group, positive control, negative control group. 3 . During the experiment, an osteoclastic cell around preexisted bone was not found. New bone formation was originated from the periphery of the remaing bone wall, and gradually extended into central portion of the bone defect. 4 . The biodegradable barrier membrane was observed favorable biocompatibility during this experimental period without any other noticeable foreign body reaction. And mineralization in the newly formed osteoid tissue revealed relatively more rapid than other group since early stage of the healing process. Conclusively, the cultured bone cell inoculated onto the biodegradable barrier membrane may have an important role of regeneration of artificial bone defects of alveolar bone. This study thus demonstrates a tissue-engineering the approach to the repair of bone defects, which may have clinical applications in clinical fields of the dentistry including periodontics.

  • PDF