• 제목/요약/키워드: Extended balcony

검색결과 21건 처리시간 0.025초

에너지 시뮬레이션을 이용한 발코니 개조에 따른 난방부하 경제성 고찰 (Economic Study on Heating load by Balcony Remodeling in use of Energy Simulation Program)

  • 김성우;박상현;임정희;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.801-806
    • /
    • 2006
  • Balcony space effects indoor thermal environment. When balcony is extended, problems would be made such as noise, dew condensation, over heating energy, and etc. Extend of balcony increase heating load about 47%. occupants must consider remodeling for their balcony. This paper compare extended balcony with unextended balcony on heating load in use of energy simulation program. According to increase heating load, we expected that building heating cost would be increased by extend balcony. To consider extend balcony, occupants must be funished with better date between healing cost increasing and floor area increasing.

  • PDF

LH공사 발코니확장형아파트 단위세대 평면계획경향에 관한 연구 (A Study on Tendency of Extended Balcony Unit Plans of LH Corp)

  • 서붕교;최정오
    • 한국실내디자인학회논문집
    • /
    • 제20권1호
    • /
    • pp.146-153
    • /
    • 2011
  • The purpose of this study was to analyze the type of extended-balcony floor plan which has been reflected as a various forms after making amendment to the apartment extended-balcony legislation on December 2005 and to understand the design tendency of housing unit plan and the characteristic of living space planning by the type of size(pyeong) and extension. The objects of analysis and the plans are 333 example(235 of $84m^2$, 98 of $59m^2$) from the LH corporation competition. The design tendency of balcony space after extension is as follows; First, a type of extension for simple area to increase the area of room adjacent to balcony through balcony extension. Second, a type of functional reinforcement for private room to separate the mixed function followed by strengthening the individual function of the private room. Third, a type of ${\alpha}$-room to play new functions as hobby room, study room, soho-type room with working from home by extending balcony. Fourth, a integrated type to increase flexible efficiency of bed room, living room and kitchen by integrating extended-balcony from the flexible plan. Along with the evaluation of living style through user's environment-behavior research and the counterplan for evacuation space, indoor thermal environment and space for fulfilling the original function of balcony should be proposed in the future study.

아파트 발코니의 확장실태와 거주자 의식에 관한 연구 (A Study of Current Status and Residents' Needs of Balcony Extension in Korean Apartment Housing)

  • 김선영;오찬옥
    • 한국실내디자인학회논문집
    • /
    • 제21권2호
    • /
    • pp.152-162
    • /
    • 2012
  • In Korean apartment housing, balcony is semi-outdoor space for storage and drying laundry. Recently, this semi-outdoor balcony space has been merged into indoor living space with the legal permission of balcony extension. It results in disappearance of the original function of balcony in apartment housing. This study attempts to propose better utilization of balcony extension by analyzing how balcony has been extended and used, and what residents' needs are. This study asks 400 housewives living in apartment housing in Jangyu new urban area, Kyungnam. Findings are : 1) Balcony extensions are carried out in a living room, a large bedroom and a small bedroom. Most extensions are made for enlarging adjacent indoor living space; 2) Original balcony that is not extended is used for drying laundry, resting, flower pot, storing, and kid's playing; 3) The residents recognize that problems of balcony extension are the decreased heating efficiency, the reduced soundproofing effect, the loss of spare housework space, and the disappearance of buffer between indoor and outdoor space; 4) Many residents want to extend their balcony space of a small bedroom and a large bedroom and to keep the balcony space of a kitchen-dining room and a master bedroom as they are.

  • PDF

공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구 (A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments)

  • 윤종호;안영섭;김병수;황상근
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구 (A Study on the Change of Indoor Thermal Environment According to the location of Blinds)

  • 황덕수;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.

공동주택 발코니의 열환경 향상방안 (Improving the Thermal Environment of Balcony in Apartment House)

  • 박선효;배상환;홍천화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.41-46
    • /
    • 2003
  • In recent days, it is usual case to extend the dwelling area to the balcony which is provided by service area. But the use of the extended area can be arisen discomfort with a view point of thermal environment by excessive heat accumulation in summer and excessive cold draft in winter. In this study, the skills were reviewed to improve the thermal environment of the extended area and evaluations were carried out. Additional heat supply by heat-convector installed at the lower end of the curtain wall can improve the thermal environment of the extended area and also arise surface temperature of the curtain wall surface. And aluminum plate installed under the floor could not improve the thermal environment but it was effective to shortening the initial heating time.

  • PDF

발코니 확장에 따른 수직화염 확대 위험성에 관한 실험적 연구 (An Experimental Study on the Risk of Vertical Flame for a Extended-Balcony)

  • 신이철;윤유혁;이주희;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.283-288
    • /
    • 2008
  • Since installing a balcony can significantly reduce the spread of fire, fire spread to the upper levels was confirmed, comparing the cases with and without balcony extension. It was confirmed that the fire can spread not only to the next higher level but also to two levels higher due to the outburst of flame which reached a significant temperature in the case without balcony, while the possibility of fire spread to the upper level reduced considerably with the balcony. this study is compared and analyzed to vertical diffusion appearance of an externally venting flame. An installed balcony is also applied to fire test 6.54kW to analyze about effect of a balcony.

  • PDF

그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구 (Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling)

  • 김웅회;강은호;윤종호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.234-235
    • /
    • 2021
  • We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

  • PDF

국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구 (A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea)

  • 이규민;구태윤;황의청;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

철근콘크리트 공동주택의 평면확장을 위한 연결부의 전단성능 평가에 관한 연구 (A Study on Shear Connector Performance Estimation for Plan Extension of RC Apartment Structures)

  • 김동백
    • 한국안전학회지
    • /
    • 제30권2호
    • /
    • pp.27-34
    • /
    • 2015
  • Nowadays, remodeling cases for some apartment like Hyundai through the support of government are reported. Conventionally, balcony and aisle are extended for additional private area or balcony which is supported by new frame is extended. In extension work at site, dowel bar is conventionally inserted in old concrete slab for connection with old and new slab, however, an examination for structural safety is rarely performed prior to construction, if ever, vertical load is only considered for structural analysis. When conventionally connected structures are exposed to earthquake, the old and new structures have individual earthquake behavior with different mode, which may lead the elimination of resistance to earthquake in new structures. As of this reason, new detailing connection system which can have light weight and sufficient ductility performance is developed for application to domestic extension works. Additionally, user manual and specification are also developed for fertilization of application for the developed technology.