• Title/Summary/Keyword: Expressway damage

Search Result 75, Processing Time 0.03 seconds

Evaluation of Installation Damage Factor for Geogrid using Maximum Particle Size of Backfill Material (뒤채움 최대입도를 이용한 지오그리드 보강재의 시공손상계수 산정 방법)

  • Kim, Kyung-Suk;Choi, Young-Chul;Kim, Tae-Soo;Lim, Seoung-Yoon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.4
    • /
    • pp.29-37
    • /
    • 2007
  • Reduction Factor for Installation Damage required for calculation of design strength of geogrid used in MSEW(mechanically stabilized earth wall) design is usually obtained in the field test simulating real construction condition. However, damages occurred in geogrid during backfill work are influenced by many factors such as polymer types, unit weight per area, backfill construction method and gradation of backfill material and field test considering these factors demands lots of time and costs. In this study, factors affecting installation damage are analyzed and empirical method for evaluating reduction factor for installation damage using maximum particle size in backfill material is suggested.

  • PDF

A Study on Improvement of Inspection Activity Based upon Condition Analysis of Expressway Bridges (고속도로 교량의 상태 분석에 근거한 점검 활동 개선에 관한 연구)

  • Jeon, Jun Chang;Lee, Il Keun;Park, Chang Ho;Lee, Hee Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • In this paper, detailed safety inspection reports on the 915 expressway bridges which had been published from 1996 to 2010 are collected and condition of these bridges are analyzed. Damages are categorized into 'damage by defect', 'damage by physical force', and 'damage by deterioration' and the concept of damage possession rate is introduced to investigate the occurrence time and the characteristics of damages. Based on the top 10 damage patterns of expressway bridges and the deterioration characteristics of heavy snow and freezing cold area, reasonable improvement direction of inspection activity is suggested. From this study, it is known that improvement of inspection regularization during construction or at completion stage of bridges is needed. Since the deterioration progress of the heavy snow and freezing cold area is faster than that of general area, environmental characteristics should be considered in inspection activity. The results of present study can be widely used for improvement of inspection activity of expressway bridges.

A Study on the Vibration Shock of Electric Appliances during Transport by Truck (트럭수송에 의한 전기.전자 제품의 진동충격에 관한 연구)

  • Lee, Soo-Keun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.9 no.1
    • /
    • pp.7-10
    • /
    • 2003
  • This study was carried out to investigate vibration shock of electric appliances during transport. Microwave oven, TV, washing machine and refrigerator were singled out as the study items. Transport courses were selected as follow ; an expressway between Kumi and Seoul for TV, an expressway between Kwangju and Seoul for microwave oven and washing machine, a national road between Inchon and Seoul for refrigerator. the values of vibration shock were measured to be ${\sim}3G$ on the national road and 1G on the expressway for up and down direction, ${\sim}0.5G$ on the national road and expressway for back and forth direction and ${\sim}0.8G$ on the national road and expressway for right and left direction. There was no damage during transport. These values were corresponding to grade II of KS A 1026 (General Rules of Performance Testing for Packaged Freights).

  • PDF

Thermal-Structure Interaction Parallel Fire Analysis for Steel-Concrete Composite Structures under Bridge Exposed to Fire Loading (화재에 노출된 교량하부 강합성 구조물에 대한 열-구조 연성 병렬화재해석)

  • Yun, Sung-Hwan;Gil, Heungbae;Lee, Ilkeun;Kim, Wooseok;Park, Taehyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.283-292
    • /
    • 2013
  • The objective of this research is to evaluate of global and local damage for steel-concrete composite structures under highway bridge exposed to fire loading. To enhance the accuracy and efficiency of the numerical analysis, the proposed transient nonlinear thermal structure interaction(TSI) parallel fire analysis method is implemented in ANSYS. To validate the TSI parallel fire analysis method, a comparison is made with the standard fire test results. The proposed TSI parallel fire analysis method is applied to fire damage analysis and performance evaluation for Buchen highway bridge. The result of analysis, temperature of low flange and web are exceed the critical temperature. The deflection and deformation state show good agreement with the fire accident of buchen highway bridge.

Modeling for Debris Flow Behavior on Expressway Using FLO-2D (FLO-2D를 이용한 고속도로에서의 토석류 거동 모델링)

  • Lim, Jae-Tae;Kim, Byunghyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.263-272
    • /
    • 2019
  • This study demonstrates the applicability of the FLO-2D for the influence analysis of the debris flow on expressway. To do this, the behavior of debris flow on the expressway was reproduced by applying the FLO-2D to actual generated debris flow. The study area is a part of the Deokyusan Service Area on the Daejon-Jinju Expressway, where traffic was blocked for 24 hours due to the debris flow in August 2005. Geographical analysis with GIS, hydrological analysis with HEC-HMS, and estimation of the amount of debris flow were carried out using field survey and soil property test data. Then, the optimum parameter combination of FLO-2D was selected through the parameter sensitivity analysis, and the behavior analysis of debris flow on expressway was applied. The comparison of the predictions with the observations shows the availability of FLO-2D for the behavior analysis of debris flow on the expressway.

Analysis of the Truck Fire Caused by Return Spring Defect of a Braking System during Expressway Driving (고속도로 주행 중 제동장치 리턴스프링 결함으로 발생한 트럭화재의 분석)

  • Kim, Younhoi;Lee, Euipyeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.148-155
    • /
    • 2014
  • Most truck fires breaking out on the expressway are directly damaged by fire destruction of truck and freight and many of them cause indirect damage such as serious traffic holdups. This study analyzed the fire causes and their liability of the 25-ton truck fire breaking out during expressway driving. This truck fire was caused by manufacturing defect of return spring of a braking system. The fire liability rested with a maker(manufacturer) rather than a truck owner or a driver and the maker also bore fire liability based on the Product Liability Law.

A Study on Cause Analysis and Countermeasures of Chloride Attack of Reinforced Earth Retaining Walls Installed on Bridge Abutment (염해로 인한 교대부 보강토옹벽 손상 원인 분석 연구)

  • Do, Jong-Nam;Kim, Nag-Young;Cho, Nam-Hun;You, Kwang-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.59-64
    • /
    • 2018
  • The damages to the reinforced earth retaining wall are divided into the front wall, foundation, drainage and upper slope. Damage of reinforced earth retaining wall is mainly caused by damage caused by drainage problem in the field. Recently, damage caused by snow removal materials have been occurred. Recently, the amount of snow removal materials used in winter is increasing due to abnormal weather. This chlorides degrades the concrete structure, where the reinforced earth retaining wall was no exception. There has recently been a case in which the front wall of the reinforced earth retaining wall deteriorates due to the chlorides introduced into the back filling portion through the drainage passage. Therefore, in this study, the cause of damages of reinforced earth retaining wall constructed in bridge abutment was analyzed, and an analytical study was conducted on the countermeasure. As a result, it was found that chlorides, which was introduced through the drainage system in the expansion joint of the bridge shift part or the upper structure, is infiltrated into the back part of the reinforced earth retaining wall and damaged. Therefore, it is suggested to improve the drainage system and restored the stiffness of the front wall.

Post-Fire Damage and Structural Performance Assessment of a Steel-Concrete Composite Bridge Superstructure Using Fluid-Structure Interaction Fire Analysis (FSI 화재해석을 이용한 강합성 교량 상부구조의 화재 후 손상 및 구조성능 평가)

  • Yun, Sung-Hwan;Gil, Heungbae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.627-635
    • /
    • 2021
  • The fire damage and structural performance of a steel-concrete composite superstructure under a highway bridge exposed to fire loading was evaluated. To enhance the accuracy and efficiency of the numerical analysis, a proposed fluid-structure interaction fire analysis method was implemented in Ansys Fluent and Ansys Mechanical. The temperature distribution and performance evaluation of the steel-concrete composite superstructure according to the vertical distance from the fire source to the bottom flange were evaluated using the proposed analysis method. From the analysis, the temperature of the concrete slab and the bottom flange of the steel-concrete composite superstructure exceeded the critical temperature. Also, when the vertical distance from the fire source was 13 m or greater, the fire damage of the steel-concrete composite superstructure was found to within a safe limit.