Model Algorithms for Estimates of Inhalation Exposure and Comparison between Exposure Estimates from Each Model (흡입 노출 모델 알고리즘의 구성과 시나리오 노출량 비교)

  • Park, Jihoon;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.358-367
    • /
    • 2019
  • Objectives: This study aimed to review model algorithms and input parameters applied to some exposure models and to compare the simulated estimates using an exposure scenario from each model. Methods: A total of five exposure models which can estimate inhalation exposure were selected; the Korea Ministry of Environment(KMOE) exposure model, European Centre for Ecotoxicology and Toxicology of Chemicals Targeted Risk Assessment(ECETOC TRA), SprayExpo, and ConsExpo model. Algorithms and input parameters for exposure estimation were reviewed and the exposure scenario was used for comparing the modeled estimates. Results: Algorithms in each model commonly consist of the function combining physicochemical properties, use characteristics, user exposure factors, and environmental factors. The outputs including air concentration ($mg/m^3$) and inhaled dose(mg/kg/day) are estimated applying input parameters with the common factors to the algorithm. In particular, the input parameters needed to estimate are complicated among the models and models need more individual input parameters in addition to common factors. In case of CEM, it can be obtained more detailed exposure estimates separating user's breathing zone(near-field) and those at influencing zone(far-field) by two-box model. The modeled exposure estimates using the exposure scenario were similar between the models; they were ranged from 0.82 to $1.38mg/m^3$ for concentration and from 0.015 to 0.180 mg/kg/day for inhaled dose, respectively. Conclusions: Modeling technique can be used for a useful tool in the process of exposure assessment if the exposure data are scarce, but it is necessary to consider proper input parameters and exposure scenario which can affect the real exposure conditions.

Prediction of Exposure and Risks of Environmental Pollutants via Emission Assessment and Multimedia Transport Modeling (배출량산정모델과 다중매질모델링을 이용한 환경오염물질의 노출평가 및 위해도 평가)

  • Kim, Jong Ho;Kwak, Byoung Kyu;Shin, Chee Burm;Jeon, Won Jin;Yi, Jongheop
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.248-257
    • /
    • 2009
  • In this paper, human exposure and risk of environmental pollutants were predicted using an emission assessment model and multimedia fate model. Eight environmental pollutants, acetaldehyde, acrylonitrile, aniline, benzene, carbon tetrachloride, dichloromethane, formaldehyde and vinyl chloride, were selected for the risk assessment in an urban and industrial area in Korea. The emission rate of target pollutants were estimated after considering a variety of point and non-point emission sources including geographical information. A spatially refined multimedia fate model was applied to predict the environmental concentration and fate of pollutants. Hazard data of target materials were obtained from the IRIS(Integrated Risk Information System) database. Using the modeling results with hazard data, the human risks were assessed. Modeling results demonstrate that the considerable risks were observed for several pollutants.

Review of Exposure Assessment to Obtain Exposure Factors of Consumer Products (소비 생활용품의 노출계수 조사 방법의 고찰)

  • Park, Ji Young;Lee, Kiyoung;Shin, Ho-Sang;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.6
    • /
    • pp.532-540
    • /
    • 2013
  • Background: Exposure factors for consumer products have been developed since the 1980s. Such exposure factors are important in risk assessment. Since the exposure/use patterns of consumer products in a country may reflect its respective cultural, meteorological, and socio-economic circumstances, unique Korean exposure factors for consumer products are needed. Such exposure factors are required for newly-enacted chemical regulations in Korea. For this review, published papers and survey reports on exposure factors of consumer products were examined for their assessment methodologies. Results: Investigation into exposure factors for consumer products used a variety of methods: home visit, online, telephone, and mail surveys using questionnaires; face to face interviews; modeling using a constructed database; and direct measurement. To collect more accurate exposure information or to check the reliability of the sampling method, some studies were repeated using the same questionnaire, in-home observation, direct measurement of usage, and videotaping. In Korea, nationwide exposure surveys were conducted five times over five years to obtain Korean exposure factors. However, with the exception of the $5^{th}$-year study, the surveys were online questionnaires and only the $5^{th}$-year study validated the accuracy of exposure information by re-visits and direct measurement. Conclusion: Accurate exposure factors are an essential part of risk assessment to assure safe use of consumer products. For better and safer management of consumer products, accurate exposure factors in Korea should be assessed for various exposure pathways.

Development of Exposure Level Prediction Program in Radioactive Waste Work (방사성 폐기물 작업 중의 피폭서량 예측 프로그램 개발)

  • Park, Won-Man;Kim, Yoon-Hyuk;Whang, Joo-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.71-77
    • /
    • 2005
  • In spite of the importance of nuclear power as one of major electric energies in Korea, the nuclear safety has become the most serious social issue in the operation of the nuclear power plant. In this paper, a virtual work simulation program was developed to predict exposure dose during radiation work in radwaste storage. The work simulation program was developed. using $Java ^{TM}$applet and VRML-virtual reality modeling language. A numerical algorithm to find the optimal work path which minimize exposure dose during the given work, was developed and exposure dose on the optimal work path was compared with that on the shortest path. Comparing with the shortest path for the given work, the predicted optimal path consumed longer work time by II% but reduced total exposure dose by 46%. The simulation result showed that the exposure dose depended on not only work time, but also the distance between the worker and the radiation source. The developed simulation program could be a useful tool for the planning of radioactive waste work to increase the radiation safety of workers.

Assessment of Chemical Risks in Moroccan Medical Biology Laboratories in Accordance with the CLP Regulation

  • Mourry, Ghita E.;Alami, Rachid;Elyadini, Adil;Hajjaji, Souad El;kabba, Saad El;Zouhdi, Mimoun
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.193-198
    • /
    • 2020
  • Background: Medical laboratory workers are frequently exposed to a wide range of chemicals. This exposure can have adverse effects on their health. Furthermore, a knowledge lack of the chemical risk increases the likelihood of exposure. The chemical risk assessment reduces the risk of exposure to hazardous chemicals and therefore, guarantees health and safety of the workers. Method: The chemical risk assessment was conducted using a modified INRS method, according to the new CLP Regulation, of 11 unit laboratories in a Moroccan medical laboratory. Observation of each workstation and analysis of safety data sheets are key tools in this study. Results: A total of 144 substances and reagents that could affect the health of the analytical technicians were identified. Among these products, 17% are concerned by the low priority risk score, with 55% concerned by the average priority risk score and 28% concerned by the high priority risk score. This study also enabled to better identify the chemical agents that have restrictive occupational exposure limit value and controls were conducted to this effect. On the basis of the results obtained, several corrective and preventive measures have been proposed and implemented. Conclusion: Risk assessment is essential to ensure the health and safety of workers and to meet regulatory requirements. It enables to identify all the risky manipulations and to adopt appropriate preventive measures. However, it is not a one-time activity but it must be continuous in order to master the changes and thus ensure the best safety of all.

Road Traffic Noise Simulation for Small-scale Urban Form Alteration Using Spatial Statistical Model (공간통계모형을 이용한 소규모 도시 형태 변경에 따른 소음도 예측)

  • Ryu, Hunjae;Chun, Bum Seok;Park, In Kwon;Chang, Seo Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.284-290
    • /
    • 2015
  • Road traffic noise is closely related with urban forms and urban components, such as population, building, traffic and land-use, etc. Hence, it is possible to minimize the noise exposure problem depending on how to plan new town or urban planning alteration. This paper provides ways to apply for urban planning in consideration of noise exposure through road traffic noise estimation for alteration of small-scale urban form. Spatial autoregressive model from the former study is used as statistical model for noise simulation. The simulation results by the spatial statistical model are compared with those by the engineering program-based modeling for 5 scenarios of small-scale urban form alteration. The error from the limitation of containing informations inside the grid cell and the difficulties of reflecting acoustic phenomena exists. Nevertheless, in the stage of preliminary design, the use of the statistical models that have been estimated well could be useful in time and economically.

Ozone Exposure Assessment by Population Characteristics: A Case Study for High Ozone Days in Busan (인구특성을 고려한 노출평가: 부산지역 고농도 오존일 사례연구)

  • Hwang, Mi-Kyoung;Bang, Jin-Hee;Oh, Inbo;Kim, Yoo-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.71-81
    • /
    • 2015
  • Objectives: Photochemical ozone pollution is associated with increased mortality risk. This study aims to assess the population exposure to ozone according to population characteristics for high ozone days in the Busan metropolitan region (BMR). Methods: The ozone exposure assessment in this study was performed using the WRF-CMAQ simulated ozone concentrations and the population data in the BMR. The settled and daytime population and their activity were considered to conduct the static and dynamic ozone exposure assessment. Results: Applying a static exposure assessment, in case that high ozone occurred throughout Busan area, the highest exposure levels were evaluated in urban neighborhoods. In case of ozone pollution in outer Busan, because sensitive groups have been relatively higher exposure, this case was also evaluated as part of that should not be overlooked. The dynamic exposure was higher than static exposure because the number of population exposed to ozone of high concentration is increased. This approach is important in a regard consider that daytime population distribution when high ozone occur. Conclusion: This study shows the different population exposure according to various ozone distributions for each episode day. Considering demographic characteristic such as population density and activity should be important to understanding the population exposure assessment when ozone pollution occurs.

Prediction of Photopolymer Solidification for Inclined Laser Beam Exposure (레이저 빛의 경사노광 시 광 경화성 수지의 경화형상 예측)

  • Kim, Young-Hyun;Lim, Jong-Seon;Yu, Gyu-Sang;Lee, In-Hwan;Ko, Tae-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.8
    • /
    • pp.98-104
    • /
    • 2010
  • It has been reported that the photopolymer solidification in the stereolithogrpahy process is mainly depend on the laser exposure conditions such as laser power and scanning speed. However, these researches were focused on the vertical laser exposure onto the surface of the photopolymer. In this research, we developed a mathematical model for the photopolymer solidification under the inclined laser beam exposure. Using the developed mathematical model, the photopolymer solidifications were simulated varying inclined laser exposure conditions. Developed mathematical model was in good agreement with the experimental result. This research can be applied to improve the surface roughness in the stereolithogrpahy process.