• Title/Summary/Keyword: Exposure modeling

Search Result 199, Processing Time 0.027 seconds

Analysis of Near Field for Base Station Panel Antenna(4 X 2 Dipole Array) (기지국용 판넬 안테나(4 X 2 Dipole Array)의 근역장 분석)

  • Lee, Dugro;Park, Ju-Derk;Choi, Jae-Ic;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.473-479
    • /
    • 2004
  • In this paper, power density in near field is calculated about analytic object which has comparatively large volume in considering used wavelength such as cellular base station antenna. Panel sector antenna which is used widespreadly in domestic cellular wireless communication system is modeled and electromagnetic field distribution in reactive near field region is calculated by FDTD (Finite Difference Time Domain) method. After that, antenna gain in far field region is obtain by near to far transformation. Power spectral density in radiated near field is calculated in applying to gain-based model with antenna gain in far field. Finally, compliance distance is obtained in considering the result from radiated near field calculation and basic restrictions on occupational and general public exposure limits in ICNIRP guideline. In the center of main radiating position, the result from gain-based model is -14.55 ㏈m and the result from surface scanning method is -15.75 ㏈m. When the losses from cables and connectors used in measurement are considered, the results from gain-based model and surface scanning method are nearly coincident.

A High-resolution Numerical Simulation and Evaluation of Oak Pollen Dispersion Using the CMAQ-pollen Model (CMAQ-pollen 모델을 이용한 참나무 꽃가루 확산 고해상도 수치모의 및 검증)

  • Oh, Inbo;Kim, Kyu Rang;Bang, Jin-Hee;Lim, Yun-Kyu;Cho, Changbum;Oh, Jae-Won;Kim, Yangho;Hwang, Mi-Kyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.1
    • /
    • pp.31-44
    • /
    • 2017
  • The aim of this study is to evaluate the accuracy and variability of the oak pollen concentrations over the Seoul metropolitan region (SMR) simulated by the Community Multiscale Air Quality (CMAQ)-based pollen dispersion model, which is the CMAQ-pollen model integrated with the improved oak pollen emission model(PEM-oak). The PEM-oak model developed is based on hourly emission flux parameterization that includes the effects of plant-specific release, meteorological adjustment, and diurnal variations of oak pollen concentrations. A 33 day-run for oak pollen simulation was conducted by the CMAQ-pollen model with a 3 km spatial resolution for the SMR during the 2014 spring pollen season. Modeled concentrations were evaluated against the hourly measurements at three Burkard sampling sites. Temporal variations of oak concentrations were largely well represented by the model, but the quantitative difference between simulations and measurements was found to be significant in some periods. The model results also showed that large variations in oak pollen concentrations existed in time and space and high concentrations in the SMR were closely associated with the regional transport under strong wind condition. This study showed the effective application of the CMAQ-pollen modeling system to simulate oak pollen concentration in the SMR. Our results could be helpful in providing information on allergenic pollen exposure. Further efforts are needed to further understand the oak pollen release characteristics such as interannual variation of the oak pollen productivity and its spatio-temporal flowering timing.

Methodology to Predict Service Lives of Pavement Marking Materials (도로 차선 재료의 공용수명 예측방법)

  • Oh, Heung-Un;Lee, Hyun-Seock;Jang, Jung-Hwa;Kang, Jai-Soo
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.151-159
    • /
    • 2008
  • Performances of retroreflectivity vary place to place, according to traffic volumes and time lengths after striping, depending on pavement marking materials and colors. The present paper uses the nation wide data of retroreflectivity, which has been collected from freeways and then tries to develop the regression curve setting traffic volume and service life as independent variables and retroreflectivities as dependent variables. The DB system includes two year's measurement in $2005{\sim}2006$ over Korean freeway pavement marking at an interval of three months for the period. The mobile measurement system, a laserlux, was employed for the purpose. The DB has provided a lot of information about materials and performance of the specific pavement marking such as geometric features, traffic volumes, material characteristics and the installation date. This study provides the comparison of pavement marking performances under diversified conditions. Based on accumulated pavement marking performances, this study provides performance curves based on the diversified factors. The goal of the retroreflectivity modeling is to develop equations that can be used to estimate an average retroreflectivity of pavement markings as a function time since application and traffic volume. After representing the variation of retroreflectivities and estimating regression curves by linear, exponential, logarithmic and power function, the regression curve which had the highest coefficient of determination and the value similar to the last field measurement was regarded as the retroreflectivity decay model. As a result of verification, the decay model showed the signification within the 90% confidence level and especially showed the clear relation with field data according to increase of cumulative vehicle exposure. Accordingly, these models can be used to determine service lives, retroreflectivity degradation rates, and retroreflectivity of new markings.

  • PDF

Case Study on Functional Bike Design for Elderly and Disabled (고령자.장애인을 위한 기능성 자전거디자인 사례연구)

  • Hong, Jung-Pyo;Hyoung, Sung-Eun;Jin, Hye-Ryeon;Seo, Seung-Hyun;Lee, Se-Hee;Yu, Mi;Kwon, Tae-Kyu
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.17-26
    • /
    • 2011
  • Health care service's added value and sustainability has been formed, through the product developing about sports equipment and special equipment for disabled in order to improve the life quality, with the increasing population of elderly and the attention about health care. This research's design and 3 testing sections has been done according to design process for design development of functional bike. 1st test is done through researching from 4 aspects: structure, aesthetic, function and using. In the 2nd testing, 10 universal design items were used to evaluate 10 modeling samples, and sample F which has high evaluation overall was chosen. In 3rd test, evaluation was done from the user service scene about the mock-up with 1/4 scale size. PPP (product performance program) which is constructed with 60 evaluation items about functional bike's service was tested, and these items were fixed through discussing with experts. Through the result we knew the aesthetic elements had relationship with proportion, unity and typicality. In 10 items (55 survey items), the scores of items with physical exposure's minimization, simple and intuitively usage showed high, on the contrary, the other items' scores was very low, such as information delivery's consideration and thought, failure preventing. The evaluation will be done once more by health care experts, designers and elderly together if the physical model could be made for getting accurate measurement about above test result in the future.

  • PDF

Estimating Groundwater Level Variation due to the Construction of a Large Borrow Site using MODFLOW Numerical Modeling (대규모 토취장 개발 예정 지역의 수치모델을 이용한 지하수위 변동 예측)

  • Ryu, Sanghun;Park, Joonhyeong;Kim, Gyoobum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.15-23
    • /
    • 2012
  • A numerical model and field monitoring data are used to estimate a change in groundwater level at a borrow site, which will be constructed at the mountainous area with a large ground excavation in the study area, Hwaseong city. Lithologic data and hydraulic coefficients are collected at 9 boreholes and also groundwater levels are measured at these boreholes and existing wells in the study area. Additionally, groundwater recharge rate for the type of land cover is estimated using water budget analysis; 133.34mm/year for a mountainous area, 157.68mm/year for a farming area, 71.08mm/year for an urbanized area, and 26.06mm/year for a bedrock exposure area. The change in groundwater level in and around a borrow site is simulated with Modflow using these data. The result of a transient model indicates that a removal of high ground (over 40El.m) by an excavation will produce a decrease in groundwater levels, up to 1 m, around a borrow site in 10 years. It also explains that this ground excavation will bring about the decreases of 9.4% and 7.0% for groundwater recharge and surface runoff, respectively, which are the factors causing groundwater level's change. This study shows that it is required to construct the groundwater monitoring wells to observe the change of groundwater near a borrow site.

Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor (연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석)

  • Choi, Jungwoon;Lee, Sunil;Park, Ki-Jung;Seo, KyoungWoo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • The domestic unique research reactor, HANARO (Hi-flux Advanced Neutron Application ReactOr), has been constructed with the open-pool, the core is submerged in, for the multi-purpose neutron application. The reactor has a primary cooling system to remove the fission heat from the core and its connected fluidic systems. Since the works are required at the reactor pool top as a characteristic of the research reactor, the radiation shall be minimized with the operation of the hot water layer system to avoid unnecessary radiation exposure on the workers during work at the pool top. Moreover, the pool water management system is connected to the reactor pool to maintain the pool temperature below $50^{\circ}C$ to minimize the uprising radioactive gas or impurity from the colder pool bottom. For the efficient flow rate of the PWMS, the thermal capacity of heat exchanger is selected with 260 kW in the normal operation condition. In this paper, the modeling is formulated to figure out whether or not each pool temperature maintains below the temperature limit and the calculation results show that the designed PWMS heat exchanger has enough capacity with the design margin regardless of the reactor operation mode.

A Case of Proximal Renal Tubular Acidosis Accompanied by Vitamin D Deficient Rickets (비타민 D 결핍성 구루병에 동반된 근위 신 세뇨관성 산증 1례)

  • Kwon Seung-Yeon;Choi Youn-Jung;Kim Kee-Hyuck
    • Childhood Kidney Diseases
    • /
    • v.10 no.1
    • /
    • pp.58-64
    • /
    • 2006
  • In the clinical state of vitamin D deficiency, it is possible that associated phosphate depletion, parathyroid hormone excess, and hypocalcemia may all depress the proximal tubular reabsorption of bicarbonate, in addition to abnormal skeletal modeling or remodeling, Although nutritional rickets is considered a rare disease in developed countries nowadays, cases of vitamin D deficient rickets caused by various unhealthy lifestyles such as insufficient exposure to sunlight, breast feeding infants without giving vitamin D supplements, unbalanced vegetarian diets of breast feeding mothers, low-birth weight, and maternal deficiency of vitamin D or calcium are increasing. Here, we present the case of an 8 month old girl, who was completely breastfed without any weaning diet or infant vitamin supplements. She visited our emergency room with hypocalcemic seizure and subsequently was diagnosed with vitamin D deficient rickets accompanied by overt bone changes and proximal renal lobular acidosis. After intravenous(IV) and oral calcium replacement therapy(IV calcium gluconate injection 1 mEq/kg/day for 6 days, 2 mEq/kg/day for 4 days followed by oral calcium gluconate administration 4 g/day for 3 days) with vitamin D supplement(Alfacalcidol 0.5 mcg/day) during admission, serum calcium level was normalized with clinical improvement. Oral sodium bicarbonate(0.6 g/day) was administered from the $2^{nd}$ hospital day for 2 weeks, which normalized the serum bicarbonate(measured by $tCO_2$) level. Calcium and vitamin D replacement were continued for 2 weeks and 3 months each. After discontinuing medications, follow up laboratory findings showed good maintenance of serum calcium, alkaline phosphate and bicarbonate levels with complete improvement of bone X-ray findings.

  • PDF

Affected Model of Indoor Radon Concentrations Based on Lifestyle, Greenery Ratio, and Radon Levels in Groundwater (생활 습관, 주거지 주변 녹지 비율 및 지하수 내 라돈 농도 따른 실내 라돈 농도 영향 모델)

  • Lee, Hyun Young;Park, Ji Hyun;Lee, Cheol-Min;Kang, Dae Ryong
    • Journal of health informatics and statistics
    • /
    • v.42 no.4
    • /
    • pp.309-316
    • /
    • 2017
  • Objectives: Radon and its progeny pose environmental risks as a carcinogen, especially to the lungs. Investigating factors affecting indoor radon concentrations and models thereof are needed to prevent exposure to radon and to reduce indoor radon concentrations. The purpose of this study was to identify factors affecting indoor radon concentration and to construct a comprehensive model thereof. Methods: Questionnaires were administered to obtain data on residential environments, including building materials and life style. Decision tree and structural equation modeling were applied to predict residences at risk for higher radon concentrations and to develop the comprehensive model. Results: Greenery ratio, impermeable layer ratio, residence at ground level, daily ventilation, long-term heating, crack around the measuring device, and bedroom were significantly shown to be predictive factors of higher indoor radon concentrations. Daily ventilation reduced the probability of homes having indoor radon concentrations ${\geq}200Bq/m^3$ by 11.6%. Meanwhile, a greenery ratio ${\geq}65%$ without daily ventilation increased this probability by 15.3% compared to daily ventilation. The constructed model indicated greenery ratio and ventilation rate directly affecting indoor radon concentrations. Conclusions: Our model highlights the combined influences of geographical properties, groundwater, and lifestyle factors of an individual resident on indoor radon concentrations in Korea.

Effect of Burnout on Post-traumatic Stress Disorder Symptoms Among Firefighters in Korea: Data From the Firefighter Research on Enhancement of Safety & Health (FRESH)

  • Kim, Woojin;Bae, Munjoo;Chang, Sei-Jin;Yoon, Jin-Ha;Jeong, Da Yee;Hyun, Dae-Sung;Ryu, Hye-Yoon;Park, Ki-Soo;Kim, Mi-Ji;Kim, Changsoo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.52 no.6
    • /
    • pp.345-354
    • /
    • 2019
  • Objectives: It is well-known that post-traumatic stress disorder (PTSD) among firefighters contributes to their job-related stress. However, the relationship between burnout and PTSD in firefighters has rarely been studied. This study therefore explored the association between burnout and its related factors, such as trauma and violence, and PTSD symptoms among firefighters in Korea. Methods: A total of 535 firefighters participated in the Firefighter Research on Enhancement of Safety & Health study at 3 university hospitals from 2016 to 2017. The 535 participants received a baseline health examination, including questionnaires assessing their mental health. A Web-based survey was also conducted to collect data on job-related stress, history of exposure to violence, burnout, and trauma experience. The associations among burnout, its related factors, and PTSD symptoms were investigated using structural equation modeling. Results: Job demands (${\beta}=0.411$, p<0.001) and effort-reward balance (${\beta}=-0.290$, p<0.001) were significantly related to burnout. Burnout (${\beta}=0.237$, p<0.001) and violence (${\beta}=0.123$, p=0.014) were significantly related to PTSD risk. Trauma (${\beta}=0.131$, p=0.001) was significantly related to burnout; however, trauma was not directly associated with PTSD scores (${\beta}=0.085$, p=0.081). Conclusions: Our results show that burnout and psychological, sexual, and physical violence at the hands of clients directly affected participants' PTSD symptoms. Burnout mediated the relationship between trauma experience and PTSD.

Estimation of Ventilation Rates in Korean Homes Using Time-activity Patterns and Carbon Dioxide (CO2) Concentration (시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정)

  • Park, Jinhyeon;Ryu, Hyeonsu;Heo, Jung;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide ($CO_2$) and $CO_2$ generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of $CO_2$ generation by breathing to estimate the indoor $CO_2$ generation rate. To estimate the ventilation rate, several factors such as the $CO_2$ generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor $CO_2$ concentrations measured by sensors, and outdoor $CO_2$ concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The $CO_2$ generation rate from breathing was $13.9{\pm}5.3L/h$ during sleep and $15.1{\pm}5.7L/h$ in a sedentary state. Indoor and outdoor $CO_2$ concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were $42.1m^3/h$ and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.