• Title/Summary/Keyword: Exposure fusion

Search Result 117, Processing Time 0.031 seconds

Single Low-Light Ghost-Free Image Enhancement via Deep Retinex Model

  • Liu, Yan;Lv, Bingxue;Wang, Jingwen;Huang, Wei;Qiu, Tiantian;Chen, Yunzhong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.5
    • /
    • pp.1814-1828
    • /
    • 2021
  • Low-light image enhancement is a key technique to overcome the quality degradation of photos taken under scotopic vision illumination conditions. The degradation includes low brightness, low contrast, and outstanding noise, which would seriously affect the vision of the human eye recognition ability and subsequent image processing. In this paper, we propose an approach based on deep learning and Retinex theory to enhance the low-light image, which includes image decomposition, illumination prediction, image reconstruction, and image optimization. The first three parts can reconstruct the enhanced image that suffers from low-resolution. To reduce the noise of the enhanced image and improve the image quality, a super-resolution algorithm based on the Laplacian pyramid network is introduced to optimize the image. The Laplacian pyramid network can improve the resolution of the enhanced image through multiple feature extraction and deconvolution operations. Furthermore, a combination loss function is explored in the network training stage to improve the efficiency of the algorithm. Extensive experiments and comprehensive evaluations demonstrate the strength of the proposed method, the result is closer to the real-world scene in lightness, color, and details. Besides, experiments also demonstrate that the proposed method with the single low-light image can achieve the same effect as multi-exposure image fusion algorithm and no ghost is introduced.

Evaluation of the accuracy of mobile cone-beam computed tomography after spinal instrumentation surgery

  • Eom, Ki Seong;Park, Eun Sung;Kim, Dae Won;Park, Jong Tae;Yoon, Kwon-Ha
    • Journal of Trauma and Injury
    • /
    • v.35 no.1
    • /
    • pp.12-18
    • /
    • 2022
  • Purpose: Pedicle screw fixation provides 3-column stabilization, multidimensional control, and a higher rate of interbody fusion. Although computed tomography (CT) is recommended for the postoperative assessment of pedicle screw fixation, its use is limited due to the radiation exposure dose. The purpose of this preliminary retrospective study was to assess the clinical usefulness of low-dose mobile cone-beam CT (CBCT) for the postoperative evaluation of pedicle screw fixation. Methods: The author retrospectively reviewed postoperative mobile CBCT images of 15 patients who underwent posterior pedicle screw fixation for spinal disease from November 2019 to April 2020. Pedicle screw placement was assessed for breaches of the bony structures. The breaches were graded based on the Heary classification. Results: The patients included 11 men and four women, and their mean age was 66±12 years. Of the 122 pedicle screws, 34 (27.9%) were inserted in the thoracic segment (from T7 to T12), 82 (67.2%) in the lumbar segment (from L1 to L5), and six (4.9%) in the first sacral segment. Although there were metal-related artifacts, the image of the screw position (according to Heary classification) after surgery could be assessed using mobile CBCT at all levels (T7-S1). Conclusions: Mobile CBCT was accurate in determining the location and integrity of the pedicle screw and identifying the surrounding bony structures. In the postoperative setting, mobile CBCT can be used as a primary modality for assessing the accuracy of pedicle screw fixation and detecting postoperative complications.

Corrosion Behavior of Super Duplex Stainless Steel (STS 329J4L) Tubes and Fin-Tubes Used in Thermal Power Plant Applications (화력발전소용 슈퍼 듀플렉스 스테인리스 강(STS 329J4L) 조관 튜브 및 핀-튜브재의 부식거동)

  • Jin Sung Park;Yong Hyeon Kim;Seung Gab Hong;Sung Jin Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.435-446
    • /
    • 2023
  • Corrosion behaviors of laser-welded super duplex stainless steel (SDSS) tubes after exposure to an actual power plant environment for one year and those of fin-tube welded SDSS were evaluated. Results showed that corrosion damage on the back side of the SDSS tube in the direction of hot air was higher than that on the front side regardless of weldment location. However, corrosion damage showed no difference between weldment and base metal due to recovery of phase fraction in the weldment through post weld heat treatment (PWHT). Nevertheless, the SDSS tube showed severe corrosion damage along grain boundary due to surface phase transformation (δ → γ) and Cr2N precipitation caused by PWHT with a high N2 atmosphere. Corrosion resistance of the SDSS tube was recovered when degraded surface was removed. Corrosion sensitivity of a fin-tube increased significantly due to pre-existing crevice, unbalanced phase fraction, and σ phase precipitation adjacent to the fusion line. Although corrosion resistance was improved by recovered phase fraction and sufficient dissolution of σ phase during PWHT, corrosion reaction was concentrated at the pre-existing crevice. These results suggest that welding conditions for fin-tube steel should be optimized to improve corrosion resistance by removing pre-existing crevice in the weldment.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

A Study on Enacting the Radiologic Technologist Act for the Civil Right to Health in Korea (건강권과 방사선사법 제정에 관한 고찰)

  • Lim, Chang-Seon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • There are the Medical Radiation Health and Safety Act(the Patient Radiation Health and Safety Act, the Radiologic Technologist Act), the Medical Laboratory Technologist Act, the Physical Therapy Practice Act, and the Dental Hygienist Act, etc in America. However, Korea has only one Act for a medical radiologic technologist(including radiation therapy technologist, nuclear medicine technologist), medical laboratory technologist, physical therapist, occupational therapy examiner, dental hygienist, and so on. It is the Medical Technologist Act. Therefore, the Medical Radiation Health and Safety Act for a radiologic technologist(including radiation therapy technologist, nuclear medicine technologist) has to be enacted independently in Korea. It is the purpose of this Act to provide for the appropriate certification of persons using radioactive materials, equipment emitting ionizing radiation on humans or performing medical imaging for diagnostic and therapeutic purposes. In Korea, the radiologic technologist is a "fusion technologist" who is a person other than a licensed practitioner as a radiographer, radiation therapist, nuclear medicine technologist, computed tomography technologist, magnetic resonance technologist, mammographer, sonographer, medical dosimetrist, quality management technologist, etc. This Act will have some provisions related to the definitions, reserved title, scope of practice, specialized technologist, application for licensure, radiologic technology council, renewal, continuing education, the radiation control advisory commission, etc. This Act will ensure that quality radiation therapy treatments are delivered and that quality diagnostic information is presented for interpretation, which will lead to accurate diagnosis, treatment and cure. Accurate diagnosis can be provided only when a personnel is properly educated in technique, equipment operation and radiation safety. In the end, this Act will protect the civil right to health. By regulating the personnel responsible for performing those procedures, this Act will mean improved care for patients-higher quality images, improved accuracy, and less exposure to radiation.

  • PDF

Histopathological effects caused by formalin bath on gill and liver of Eel (Anguilla japonica) (포르말린 약욕이 뱀장어 (Anguilla japonica)의 아가미 및 간에 미치는 병리조직학적 효과)

  • Jung, Sung-Hee;Lee, Nam-Sil;Lee, Joo-Seok;Jee, Bo-Young;Kim, Jin-Woo;Kim, Eung-Oh
    • Journal of fish pathology
    • /
    • v.20 no.3
    • /
    • pp.315-325
    • /
    • 2007
  • Histological changes in gill and liver of eel, Anguilla japonica (average weight 96±3.6 g) were examined with formalin bath at 0~500 ppm for 1, 6 and 24 h. Hyperplasia, hypertrophy, cell fusion, desquamation and necrosis of epithelial cells at gill lamella and gill filament were observed from 6 h at 200 ppm, 1 h at 300 ppm, 1 h at 400 ppm and 1 h at 500 ppm. In the exposure of formalin 100 ppm for 24 h, epithelial cells arrangement of gill filament and gill lamella showed thinner and more regular order than the control. trophy and pyknosis of hepatocytes, congestion at sinus or central vein, degeneration of cytoplasm were observed in the liver from 24 h at 100 ppm and 200 ppm, 6 h at 300 ppm, 1 h at 400 ppm and 500 ppm. However, there were not any histological changes at liver of 100 ppm-1, 6 h, 200 ppm-1, 6 h and 300 ppm-1 h compared with the tissue of control.

Ecophysiological Responses and Subsequent Recovery of the Olive Flounder, Paralichthys olivaceus Exposed to Hypoxia and Iron II. Survival, Metabolic and Histological Changes of the Olive Flounder Exposed to Iron (빈산소와 철에 대한 넙치 (Paralichthys olivaceus)의 생태생리적 반응 및 회복 II. 철에 노출된 넙치의 생존, 대사 및 조직학적 변화)

  • KANG Ju-Chan;LEE Jung-Sick;JEE Jung-Hoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.6
    • /
    • pp.699-705
    • /
    • 1999
  • The effects of iron on gill tissue and metabolic rate represented by oxygen consumption of olive flounder, Paralichthys olivaceus were determined. The effects were further studied by means of survival rate of the fish exposed to a serial concentrations of iron. The olive flounder exposed to iron concentrations over 0.93 mg/$\ell$ showed curvature and terminal clubbing of gill lamellae at 2 weeks post-exposure. In iron concentration 4.89 mg/$\ell$, gill of the fish were seriously damaged just after 2 weeks, showing hyperplasia of filament epithelia, deformation of lamella epithelia, chloride cell damage, and separation of lamella epithelial layer, Gills exposed to 9.78 mg/$\ell$ iron concentration resulted in fusion and necrosis of the lamellae after 2 weeks. Significant decreases of metabolic rate of the fish were observed after 4 weeks at iron concentration 0,93 mg/$\ell$ and after 2 weeks at iron concentrations over 4.89 mg/$\ell$. Survival rate of the olive flounder decreased significantly after 4 weeks at the iron concentration over 4.89 mg/$\ell$. These results lead us to conclude that, as far as the iron effects are concerned, its concentrations should not exceed at least more than 0.93 mg/$\ell$ in the fish farm and coastal waters for normal growth of the olive flounder.

  • PDF

Effect of Turbidity Changes on Tissues of Zacco koreanus (탁도 변화가 참갈겨니 (Zacco koreanus) 조직에 미치는 영향)

  • Shin, Myung-Ja;Kim, Jeong-Sook;Hwang, Yun-Hee;Lee, Jong-Eun;Seo, Eul-Won
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.1
    • /
    • pp.73-80
    • /
    • 2008
  • Present study aims to investigate the effect of muddy water on the gill and the kidney tissues of Zacco koreanus under high turbidity rearing condition. The gill of Z. koreanus showed abnormal shapes in its secondary lamellae and a rough surface with impure debris in the high level of turbidity and the longer raising period condition. In addition, the gills showed the edema, the exfoliation of epithelial cell, and the fusion of the secondary lamellae. In case of kidney tissue, the atrophied glomerulus was observed, and the empty space in Bowman's capsule was wider. The SOD activities in both gill and kidney tissues were increased in proportion to the high level of turbidity. On the while, CAT and GPX activities were shown constant level in the gill, but were increased in the kidney in the high turbid muddy water. These results indicate that the harmful radicals which generate by high level of turbidity could be removed partly by antioxidant enzymes in the kidney. The concentrations of micro heavy metal ions accumulated in the gill increased drastically at the 1,000 NTU. Based on the above results, it is considered that the exposure to the high level of turbidity for long period may affect on the structures of tissues, and change the enzymatic balance in Z. koreanus, causing the fatal disease.

Analysis on the Hanbok Image, Perception and Preference Type of High School Students: Focused on Participation in Hanbok Classes and Gender (고등학생의 한복 이미지, 선호 유형, 전통한복 인식 분석: 한복수업 참여 여부 및 성별을 중심으로)

  • Kim, Sangmi
    • Journal of Korean Home Economics Education Association
    • /
    • v.33 no.2
    • /
    • pp.81-93
    • /
    • 2021
  • The purpose of this study was to analyze the image, perception, and preference type of high school students of Hanbok and examine the differences according to gender and participation in Hanbok classes. For this purpose, a survey was conducted with 438 high school students in Busan. Frequency analysis, chi-square test, t-test, and F-test were performed using the SPSS and the results were as follows. Firstly, for most high school students, Hanbok has an elegant image, but it was also confirmed that they perceive Hanbok to have a splendid image due to its exposure in mass media and SNS. The image of Hanbok differed by gender and participation in Hanbok classes. A higher percentage of male students than female students perceived Hanbok to have rustic image. Secondly, the type of hanbok that high school students prefer was traditional Hanbok, followed by fusion Hanbok, casual Hanbok, and fashion Hanbok. Hanbok preference type differed by gender and participation in classes. Group participating in hanbok classes showed a higher preference for fashion Hanbok than those who did not. Thirdly, high school students' perception of traditional Hanbok was above average. By subcomponents, it was shown in the order of 'esthetics', 'sustainability', and 'practicality'. It was found that there were statistically significant differences in traditional Hanbok perception according to gender and participation in Hanbok classes. Female students evaluated more positively for traditional Hanbok than male students and students who participate in Hanbok classes evaluated traditional Hanbok more positively than non-participating students.

Smart window coloring control automation system based on image analysis using a Raspberry Pi camera (라즈베리파이 카메라를 활용한 이미지 분석 기반 스마트 윈도우 착색 조절 자동화 시스템)

  • Min-Sang Kim;Hyeon-Sik Ahn;Seong-Min Lim;Eun-Jeong Jang;Na-Kyung Lee;Jun-Hyeok Heo;In-Gu Kang;Ji-Hyeon Kwon;Jun-Young Lee;Ha-Young Kim;Dong-Su Kim;Jong-Ho Yoon;Yoonseuk Choi
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.90-96
    • /
    • 2024
  • In this paper, we propose an automated system. It utilizes a Raspberry Pi camera and a function generator to analyze luminance in an image. Then, it applies voltage based on this analysis to control light transmission through coloring smart windows. The existing luminance meters used to measure luminance are expensive and require unnecessary movement from the user, making them difficult to use in real life. However, after taking a photography, luminance analysis in the image using the Python Open Source Computer Vision Library (OpenCV) is inexpensive and portable, so it can be easily applied in real life. This system was used in an environment where smart windows were applied to detect the luminance of windows. Based on the brightness of the image, the coloring of the smart window is adjusted to reduce the brightness of the window, allowing occupants to create a comfortable viewing environment.