Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography (유방촬영용장치 부가필터에 따른 선량변화 및 화질개선)

  • Cho, Woo Il;Kim, Young Kuen;Lee, Gil Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.78-90
    • /
    • 2013
  • Recently, the interest on exposure to radiation is rising. The radiation exposure of mammography is higher in absorbed dose than of X-ray, therefore unnecessary exposure needs to be reduced, and higher image quality is needed. Generally, ray quality of the radiation imaging is an important factor that determines image quality and the amount of ray exposure, and they are affected by tube voltage and added filter. The X-ray energy that is exposed from mammography device is generally a continuous spectrum, which includes low energy that has minute influence on the image quality, and high energy that hinders contrast on image. Currently, molybdenum (Mo) and rhodium (Rh) are the most used added filters for mammography device, and they are used differently according to the energy region of X-ray. This study aims to find out the degree of reduction in exposure dose according to the thickness of aluminum (Al), and to study the changes in image quality and dose when the added filter plates that are made with niobium (Nb) or zirconium (Zr) are used, other than molybdenum (Mo) and rhodium (Rh), the two most used added filters that have similar atomic number and K-absorption regions as Nb and Zr. In this study, single-added filters of molybdenum (Mo), niobium (Nb), and zirconium (Zr) are used, and in some cases, Aluminum (Al) is combined with the single filters. In this case, image quality is considered to be improved depending on the type of added filters, and by using Aluminum (Al) filter together with the others, unnecessary X-ray of low energy would be absorbed, therefore the dose is expected to decrease without any influence when the concentration level becomes identical.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Electromagnetic energy as an impact factor on life processes of a biological object of a plant origin

  • Radko, I.;Nalyvaiko, V.;Okushko, O.
    • The Korean Journal of Food & Health Convergence
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • The foremost problem in the agricultural industry in Ukraine is the issue of improving its energy resources efficiency. The existence of this problem is related to the substantial technological inferiority of the industry to those present in the developed countries, especially in terms of creation of no-waste production technologies of agricultural products. The direct effect on the solving of this issue has the necessity to ensure minimal energy costs during treatment of plant objects. This article presents the research results on the effect of electromagnetic energy on activation of plants development. It was found that each such object has its own individual energy resource and that forceful increase of the latter has specific maximum values and gives rise to the plant development process. At the same time, the implementation of the research results is hindered by some factors, among the most major of which are the following: lack of reliable and complete data on the bioenergy resources of plants, its "natural" chart; unavailability of research on the energy sources interaction processes and its effect on the physiological potential of biological objects, at least at the level of low series, absence of the appropriate electrotechnical equipment, including electromagnetic energy sources.

A Study on Measurement of the Half Value Layer in Diagnostic X-ray (진단용(診斷用) X선(線)의 반가층(半價層)에 관(關)한 연구(硏究))

  • Ko, Shin-Gwan
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.53-66
    • /
    • 1984
  • The quality of continuous x-ray beam depends upon the half value layer which varies according to the geometric conditions, the filtration thickness, and the amount of accelerated voltage (KVP). Experiments were conducted on the amount of electric energy that was changed to x-ray energy, and on the relationship between KVp and the intensity of x-rays. The results were as follows: 1. The amount of x-rays were not equal under the condition of the same exposure factor. 2. The intensity of x-rays was attenuated by an exponential function the geometric conditions were "good" and it was not when they were "poor". 3. The thicker the total filtration substance was and the higher the KVp was, the bigger the amount of x-ray energy was. 4. The homogeneity of medium energy x-ray was the best, when the total filtration substance was 3.9mm A1. 5. The mean energy of continuous x-ray was about 45% of KVp.

  • PDF

Characterization of Thermal Degradation of Polymide 66 Composite: Relationship between Lifetime Prediction and Activation Energy (폴리아미드 66 복합소재의 열 열화 특성: 수명 예측과 활성화 에너지의 상관관계)

  • Jung, Won-Young;Weon, Jong-Il
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.712-720
    • /
    • 2012
  • Thermal degradation for glass fiber-reinforced polyamide 66 composite (PA 66) with respect of thermal exposure time has been investigated using optical microscopy, scanning electron microscopy and Fourier transform infrared spectroscopy. As the thermal exposure time was prolonged, a slight increase in tensile strength for only initial stage and afterward, a proportional decrease of tensile strength was observed. These results can be explained by the increase of crystallinity, followed by the increase of crosslinking density, chain scission and the decrease in chain mobility, due to thermal oxidation with the exposure time. Fourier transform infrared spectroscopy results showed the increase of ketone peak and silica peak on the surface of thermally exposed PA 66. In addition, the thermal decomposition kinetics of PA 66 was analyzed using thermogravimetric analysis at three different heating rates. The relationship between activation energy and lifetime-prediction of PA 66 was investigated by several methodologies, such as statistical tool, UL 746B, Ozawa and Kissinger. The activation energy determined by thermogravimetric analysis had a relatively large value compared with that from the accelerated test. This may result in over-estimating the lifetime of PA 66. In this study, a master curve of exponential fitting has been developed to extrapolate the activation energy at various service temperatures.

Treatment of Radioactive Liquid Waste Using Natural Evaporator and Resulted Exposure Dose Assessment (증발을 이용한 방사성 액체폐기물의 처리와 피폭선량평가)

  • Jeong, Gyeong-Hwan;Park, Seung-Kook;Kim, Eun-Han;Jung, Ki-Jung;Park, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.101-108
    • /
    • 1999
  • The influence of the relative humidity, the temperature and the velocity of supply air on evaporation rate has been studied with non-boiling forced evaporation system in order to treat very low level radioactive liquid wastes produced from the decontamination and decommissioning activities. Experimental data on the evaporation rate have been obtained with the divers variables and experimental equation of air velocity was also obtained by the correlation of those data. The decontamination factor of this system was also obtained by the experimental data from a simulated liquid waste containing Cs-137 radio isotope ; $DF=10^4$. Since the commercial system will be operated for the treatment of the very low level radioactive liquid waste produced from decontamination & decommissioning of TRIGA Mark-II&III research reactor, the environmental assessment has been conducted to improve the operational safety. Exposure dose rate for an individual member of general public was assessed, and it showed that it was very lower than individual dose limits. The release of radioactivity of radioisotope material (Cs-137) to the environment was assessed, and result showed that it was $4.637{\times}10^{-14}\;{\mu}Ci/cc$.

  • PDF

Adhesion and Lifetime Extension Properties of Electrical Conductive Paint Stored under of Nitrogen Atmosphere (질소환경에서 보관된 전기전도성 페인트의 접착 및 수명연장 특성)

  • Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Ha-Seung;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.20 no.1
    • /
    • pp.9-14
    • /
    • 2019
  • The change of three different reagents for electrical conductive paint using aircraft coating with elapsing time of exposure to different condition was investigated. Three different reagents were poured into the vial bottles, stored in air condition and room temperature and observed with elapsing days. In addition, adhesion property of paint was tried using cross cut tape test after storage of $N_2$ atmosphere. The weight of each different reagent was measured along with elapsing time. To confirm the change of chemical component with exposure of air atmosphere, FT-IR was performed. The weight of part A and Part B decreased slightly whereas the weight of part C decreased rapidly and the precipitation was remained. The part B was cured after exposure of $N_2$ atmosphere and the 2250 cm-1 from FT-IR peak decreased slowly at the same time. It was considered that the water contained in air accelerated the reaction of -NCO functional groups and it caused the curing whereas $N_2$ atmosphere not contained water and it resulted in the retardancy of curing.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Measurement of low energy beta radiation from Ni-63 by using peeled-off Gafchromic EBT3 film

  • Ji, Wanook;Kim, Jong-Bum;Kim, Jin-Joo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3811-3815
    • /
    • 2022
  • Ni-63 is pure beta source which emits low energy beta particles. The Ni-63 sources were fabricated to develop the beta-voltaic battery which converts decay energy into electrical energy for power generation. Activity distribution of the source was important factor of power producibility of the beta-voltaic battery. Liquid scintillation counter widely used for measurement of low energy beta emitters was not suitable to measure activity distribution. In this study, we used the peeled-off Gafchromic™ EBT3 film to measure the activity distribution of the Ni-63 source. Absorbed dose was increased proportionally to the source activity and exposure duration. The low energy beta particles could transport the energy into the active layer without the polyester protective layer. Also, Activity distribution was measured by using the peeled-off EBT3 film. Two-dimensional dosimetric distribution was suitable to measure the activity distribution. To use the peeled-off EBT3 film is user-friendly and cost-effective method for quality assurance of the Ni-63 sources for the beta-voltaic battery.