• Title/Summary/Keyword: Exposure dose rate

Search Result 377, Processing Time 0.028 seconds

Effective Half-life of I-131 in Patients with Differentiated Thyroid Cancer Treated by Radioactive I-131 (I-131 치료를 받은 분화갑상선암 환자에서 I-131의 유효반감기)

  • Park, Seok-Gun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.464-468
    • /
    • 2008
  • Purpose: Effective half life of I-131 ($T_{eff}$) in patients with differentiated thyroid cancer treated by I-131 is must-know value for dose calculation and determination of release time from isolation room. There has been no report about $T_{eff}$ in Koreans. Thus, author tried to measure dose rate without radiation exposure to faculty members and calculated $T_{eff}$. Methods: Probe of radiation survey meter was fixed at the wall of isolation room, and body of survey meter was placed outside the room. With this simple arrangement, author could measure radiation frequently without radiation exposure to faculty members in 68 patient (F=55, M=13, age=$47{\pm}13.7$) treated by I-131 ($3.7{\sim}7.4\;GBq$) for differentiated thyroid cancer from Jan 2006 to Dec 2006. From this data, $T_{eff}$, 48 hr retention rate, and the time necessary to whole body retention of I-131 become less than 1.1 GBq were calculated. Serum creatinine levels were measured before and after thyroid hormone withdrawal. Results: $T_{eff}$ was $15.4{\pm}4.3\;hr$ ($9.4{\sim}32.5\;hr$). There was a loose correlation between $T_{eff}$ and serum creatinine concentration (r=0.45). 48hr retention was $4.9{\pm}4.2%$ ($1{\sim}23%$). Time necessary to whole body retention of I-131 become less than 1.1 GBq was calculated as $47.1{\pm}13.2\;hr$ for 9.25 GBq, $42.1{\pm}11.9\;hr$ for 7.4 GBq, $35.7{\pm}10.0\;hr$ for 5.55 GBq, and $26.7{\pm}7.5\;hr$ for 3.7 GBq dose of I-131. Conclusion: Author successfully measured radiation dose rates in isolated patients treated by high dose of I-131 without radiation exposure to the faculty members with simple arrangement of survey meter probe. Using those data, $T_{eff}$ and some other indices were calculated.

Increase in the Th1-Cell-Based Immune Response in Healthy Workers Exposed to Low-Dose Radiation - Immune System Status of Radiology Staff

  • Karimi, Gholamreza;Balali-Mood, Mahdi;Alamdaran, Seyed-Ali;Badie-Bostan, Hassan;Mohammadi, Elaheh;Ghorani-Azam, Adel;Sadeghi, Mahmood;Riahi-Zanjani, Bamdad
    • Journal of Pharmacopuncture
    • /
    • v.20 no.2
    • /
    • pp.107-111
    • /
    • 2017
  • Objectives: Radiation is one of the most important sources of free radical (such as reactive oxygen species) production, which plays an essential role in the etiology of over hundred diseases. The aim of the study was to investigate some immune parameters and hematological indices in healthy workers of the Radiology Department, University Hospital of Mashhad, Iran. Methods: The study was performed on 50 healthy workers: 30 radiology staff as the case group and 20 laboratory workers as the control group. The radiation dose received by the radiology staff participating in the study was less than the annual maximum permissible level, 50 millisievert. Hematological parameters, lymphocyte proliferation and cytokine production were studied in both groups. Results: Among healthy radiology workers, the hematological indices did not differ statistically; however, their proliferation indices and $IFN-{\gamma}$ levels showed significant increases in parallel with decreases in the IL-4 levels as compared to controls. The immune system of workers exposed to low-dose ionizing radiation was found to be shifted from a Type 2 to a Type 1 response to promote cellular immunity. Conclusion: Based on our data, exposure to low-dose ionizing radiation may decrease the prevalence, frequency, and recurrence of various cancers and infectious diseases because of an increase in Th1-cell-based response, thus leading to more protection of the human body against tumor cells and foreign agents and possibly increased longevity. However, due to high rate of fluoroscopy use for interventional radiology, we suggest continuing research projects on radiation protection and hazards to prevent irreversible damage. As a recommendation, in future studies, radiology staff with a weakened immunity due to high radiation exposure should be considered as good choices to be treated using acupuncture techniques because acupuncture has been demonstrated to enhance the function and the number of immune cells.

Immunogenicity and Protective Efficacy of Solubilized Merozoite-enriched Theileria sergenti Immunogens. II. Protection against Natural Exposure under Field Conditions (Theileria sergenti merozoite 수용성 항원의 항원성과 면역성 II. 자연 조건하에서의 감염에 대한 면역시험)

  • 백병걸;김병수
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.3
    • /
    • pp.201-208
    • /
    • 1992
  • A Theileria sergenti soluble merozoite preparation containing the 29, 34, 35 and 105 KD as the immunodominant polypeptides, was evaluated for efficacy, safety and protectivity in Holstein calves against virulent field tick challenge. The soluble antigens (100 mg/dose) were fortified with either complete or incomplete Freund's adjuvant. Twenty naive calves, aged one month, were subcutaneously inoculated with the preparation and a booster dose was administered 4 weeks later. Twenty additional calves served as controls. Five weeks after the booster dose, vaccinates and uninoculated controls were moved to a pasture, a heavily tick infested area in Cheju-do, Korea. The vaccinates showed negligible change in hematocrit and total RBC count whereas control animals showed significant (p<0.05) hematological changes and associated anemia. Only 30% of vaccinates required chemotherapy after the experiment was terminated. All control animals required chemotherapy and 25% received blood transfusion. The highest percent parasitized erythrocytes in vaccinated cattle was 0.4% as compared with 3.6% among controls during the month of July. A significant difference (p<0.05) was observed in the rate of body weight increase. Significant difFerences were also noted in serum albumin, aspartate aminotransferase, total protein and bilirubin. Significantly more vaccinated cattle maintained normal ranges of hematological and biochemical values as compared with the control group. It is suggested that soluble merozoite T. sergenti antigens may be potential vaccine candidates for developing a genetic vaccine in Korea.

  • PDF

The Frequency of Chromosomal Aberrations of Peripheral Lymphocytes according to Radiation Dose and Dose Rate (선량 및 선량률 변화에 따른 말초혈액 임파구의 염색체 이상의 빈도)

  • Jeong Tae Sik;Baek Heum Man;Shin Byung Chul;Moon Chang Woo;Kim Mi Hyang;Lee Yong Hwan;Yum Ha Yong
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.138-149
    • /
    • 2000
  • Purpose : It was studied that the relationship between radiation dose, dose rate and the frequency of chromosomal aberrations in peripheral lymphocytes. Methods and Materials : Peripheral lymphocytes were irradiated in vitro with 6 MeV X-ray at dose ranges from 50 cGy to 800 cGy. The variations of the frequency of chromosomal aberrations were observed according to different radiation dose rate from 20 cGy/min to 400 cGy/min at constant total dose of 400 cGy which it was considered as factor to correct biological radiation dose measurement. Results : The yields of lymphocytes with chromosomal aberrations (dicentric chromosome, ring chromosome, acentric fragment pairs) are 0% at 50 cGy, 9% at 100 cGy, 20% at 200 cGy, 27% at 300 cGy, 55% at 400 cGy, 88% at 600 cGy, and 100% at 800 cGy. The value of Ydr is 0.000 at 50 cGy, 0.093 at 100 cGy, 0.200 at 200 cGy, 0.354 at 300 cGy, 0.612 at 400 cGy, 2.040 at 600 cGy, and 2.846 at 800 cGy. The relationship between radiation (D) and the frequency of dicentrlc chromosomes and ring Chromosomes (Ydr) can be expressed as Ydr=0.188${\times}$10$^{-2}$ D/Gy+0.422${\times}$10$^{-4}$/Gy$^{2}$${\times}$D$^{2}$ The Value of Qdr is 0.000 at 50 cGy, 1.000 at 100 cGy, 1.000 at 200 cGy, 1.333 at 300 cGy, 1.118 at 400 cGy, 2.318 at 600 cGy, and 2.846 at 800 cGy. When 400 cGy is irradiated with different dose rate each of 20, 40, 60, 80, 100, 160, 240, 320, and 400 cGy/min, Ydr is each of 0.982, 0.837, 0.860, 0.732, 0.763, 0.966, 0.909, 1.006, and 0.806, and Qdr is each of 1.839, 1.555, 1.654, 1.333, 1.381, 1.750, 1.6000, 1.710, and 1.318. Conclusion : There are not the significant variations of Ydr and Qdr values according to different dose rate. And so radiation damage is influenced by total exposed radiation doses and is influenced least of all by different dose rate when it is acute single exposure.

  • PDF

A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department (핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰)

  • Yoo, Jae-Sook;Jang, Jeong-Chan;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.50-56
    • /
    • 2012
  • Purpose: Those who access to the nuclear medicine department are classified as radiation workers, temporarily access group, and occasional access group as defined by the atomic energy law. The radiation workers and temporarily access people wear a personal radiation dosimeter for checking their own radiation absorbed dose periodically. However, because of the sanitation workers, classified as temporarily access group, who are working in the nuclear medicine department are moved in a cycle with other departments and their works are changeful, it is hard to control their radiation absorbed dose. Thus, this study is going to examine the state of the sanitation worker's radiation absorbed dose, and then make sure whether they are classified as temporarily access group or not. Materials and methods: In the first instance, the first sanitation worker who works in vitro laboratory and PET room and the second sanitation worker who works in gamma camera rooms (invivo room) wore radiation dosimeter-OSL(Optically Stimulated Luminescence)- to measure their own radiation absorbed dose during work time from May to June 2011. Secondly, this study was taken place 5 places in gamma camera rooms, 2 places in PET bed room, operating room, waiting room and cyclotron room in PET and 4 places in vitro laboratory. And then to measure the radiation space dose rate, it is measured 10 times each of places as sanitation worker's work flow by using radiation survey meter. Results: The radiation absorbed dose on OSL of the first c who works in vitro laboratory and PET room and the second one who works in gamma camera rooms are 0.04, 0.02 mSv per month respectively. That means the estimated annual radiation absorbed doses are less than 1mSv as 0.48, 0.24 mSv/yr respectively. The radiation space dose rates as sanitation worker's work flow using survey meter are 0.0037, 0.0019 mSv/day, so the estimated annual radiation absorbed dose are 0.93, 0.47 mSv/yr respectively. The weighted exposure dose of first sanitation worker of each places are 1.62% in cyclotron room, 3.88% in waiting room, 2.39% in operating room, 81.01% in bed room of PET and 11.01% in vitro laboratory. The weighted exposure dose of second sanitation worker of each places are 45.22% in radiopharmaceutical laboratory, gamma 30.64% in camera rooms, 15.65% in waiting room, 8.49% in reading room. Conclusion: The annual radiation absorbed doses on OSL of both sanitation workers are less than 1 mSv per year and the annual radiation absorbed doses by using survey meter are less than 1mSv either, but close up to 1 mSv. Thus, to clarify whether the sanitation workers are temporarily access group or not, and to be lessen their s radiation absorbed dose, they should be educated about management of radiation and modified their work flow or work time appropriately, their radiation absorbed dose would be lessen certainly.

  • PDF

Evaluation of Shielding Rate of Bismuth Depending on the Type of Medical Radioisotope (의료용 방사성동위원소의 종류에 따른 비스무트의 차폐율 평가)

  • Han, Sang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.87-93
    • /
    • 2018
  • In this study, $^{99m}Tc$, $^{123}I$, $^{201}Tl$, $^{18}F$, and $^{131}I$, which are widely used in nuclear medicine, were transmitted through a bismuth shield. We investigated the shielding rates according to the type of radioisotope and the distance of measurement. For the experiment, 6 sheets of lead equivalent 0.25 mm Pb of bismuth shielding material were stacked one by one up to 1.50 mm as the thickness increased. The distance was 30 cm, 50 cm, and 100 cm, and the transmission dose was measured. As a result, the shielding rates was measured as the thickness increased, and the measured value decreased as the distance increased. The shielding rate of $^{123}I$ and $^{201}Tl$ was higher than $^{99m}Tc$, $^{18}F$ and $^{131}I$ showed lower shielding effect when there is a shielding material than when there is no shielding material due to high energy and ${\beta}$ rays. Based on the results of experiments, it would be helpful to reduce the exposure of nuclear medicine workers and to manage the exposure if bismuth shields are used depending on the type of radioisotope.

Determinations of the Exposure Rate Using a NaI(Tl) Detector of the Environmental Radiation Monitor (환경방사선감시기의 NaI(Tl) 검출기를 이용한 조사선량률 결정방법)

  • Ji, Young-Yong;Lee, Wanno;Choi, Sang-Do;Chung, Kun Ho;Kang, Mun Ja;Choi, Geun-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.3
    • /
    • pp.245-251
    • /
    • 2013
  • The energy band and the G-factor method were compared to determine the exposure rate from the measured spectrum using a NaI(Tl) scintillation detector. First, G-factors of a 3"${\Phi}X3$" NaI(Tl) detector mounted to a EFRD 3300, which means the environmental radiation monitor, in Korea Atomic Energy Research Institute (KAERI) were calculated for several directions of incident photons through the MCNP modeling, and the optimum G-factor applicable to that monitor was then determined by comparing the results both the energy band method and the G-factor method. The results for these spectrometric determinations were also compared with the dose rate from a HPIC radiation monitor around a EFRD 3300. The measured value at the EFRD 3300 based on a 3"${\Phi}X3$" NaI(Tl) detector was $7.7{\mu}R/h$ and its difference was shown about $3{\mu}R/h$, when compared with the results from a HPIC radiation moditor. Since a HPIC is known to be able to measure cosmic rays with the relatively high energy, the difference between them was caused by cosmic rays which were not detected in a 3"${\Phi}X3$" NaI(Tl) detector.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

Establishment of Release Limits for Airborne Effluent into the Environment Based on ALARA Concept (ALARA 개념(槪念)에 의한 기체상방사성물질(氣體狀放射性物質)의 환경방출한도(環境放出限度) 설정(設定))

  • Lee, Byung-Ki;Cha, Moon-Hoe;Nam, Soon-Kwon;Chang, Si-Young;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.50-63
    • /
    • 1985
  • A derivation of new release limit, named Derived Release Limit(DRL), into the atomsphere from a reference nuclear power plant has been performed on the basis of the new system of dose limitation recommended by the ICRP, instead of the (MPC)a limit which has been currently used until now as a general standard for radioactive effluents in Korea. In DRL Calculation, a Concentration Factor Method was applied, in which the concentrations of long-term routinely released radionuclides were in equilibrium with dose in environment under the steady state condition. The analytical model used in the exposure pathway analysis was the one which has been suggested by the USNRC and the exposure limits applied in this analysis were those recommended by the USEPA lately. In the exposure pathway analysis, all of the pathways are not considered and some may be excluded either because they are not applicable or their contribution to the exposure is insignificant compared with other pathways. In case, the environmental model developed in this study was applied to the Kori nuclear power plant as the reference power plant, the highest DRL value was calculated to be as $9.10{\times}10^6Ci/yr$ for Kr-85 in external whole body exposure from the semi-infinite radioactive cloud, while the lowest DRL value was observed 3.64Ci/yr for Co-60 in external whole body exposure from the contaminated ground, by the radioactive particulates. The most critical exposure pathway to an individual in the unrestricted area of interest (Kilchun-Ri, 1.3 km to the north of the release point) seems to be the exposure pathway from the contaminated ground and the most critical radionuclide in all pathways appears to be Co-60 in the same pathway. When comparing the actual release rate from KNU-l in 1982 with the DRL's obtained here the release of radionuclides from KNU-1 were much lower than the DRL's and it could be conclued that the exposure to an individual had been kept below the exposure limits recommended by the USEPA.

  • PDF

Worker Exposure and Volatilization Pattern of Cadusafos, Ethoprophos and Probenazole after Applying Granular Type Formulation on Soil in Greenhouse (시설재배지에서 토양처리농약 Cadusafos, Ethoprophos와 Probenazole 입제 처리 후 휘산 양상과 농작업자 노출)

  • Park, Byung-Jun;Lee, Ji-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.2
    • /
    • pp.160-165
    • /
    • 2011
  • BACKGROUND: This study carried out to fate of pesticide and investigate worker exposure of pesticide in air after applying granular type pesticide formulation on soil in greenhouse for preventing farmer's pesticide intoxication. METHODS AND RESULTS: The recovery of pesticide, cadusafos, ethoprophos and probenazole on absorbent in air were ranged 80.9~121.1% in charcoal and 90.6~99.0% in XAD-4, respectively. Emission rate of in lysimeter was higher 3~5 times than that of pesticides from topsoil not added water at $35^{\circ}C$ plot after applying a mixture of granular formulation and soil. The ethoprophos concentration in air, 50 cm high from soil surface at greenhouse, was reached the highest 186.4 ${\mu}g/m^3$ within 13 hours and were ranged 17.8~186.4 ${\mu}g/m^3$ during 46 hours after applying granular formulation at dose rate 150 g a.i./245 $m^2$. The cadusafos concentration in air at greenhouse was reached the highest 37.3 ${\mu}g/m^3$ within 39 hours and were ranged 10.0~37.3 ${\mu}g/m^3$ during 46 hours after applying granular formulation at dose rate 180 g a.i./245 $m^2$. The probenazole concentration in air at greenhouse was reached the highest 1.45 ${\mu}g/m^3$ within 37 hours and were ranged 0.23~1.45 ${\mu}g/m^3$ during 46 hours after applying granular formulation at dose rate 144 g a.i./245 $m^2$. CONCLUSION(s): The result of the reentry interval study demonstrated that reentry intervals for ethoprophos and cadusafos are longer than 48 hours.