• Title/Summary/Keyword: Exposure correction

Search Result 117, Processing Time 0.03 seconds

Open Heart Correction Of Ebstein`S Anomaly: A Report Of 8 Cases (Ebstein`s 심기형의 개심수술 8예)

  • 김삼현
    • Journal of Chest Surgery
    • /
    • v.14 no.4
    • /
    • pp.388-398
    • /
    • 1981
  • Fourteen Infants with congenital cardiac anomalies underwent primary surgical Intervention within the first 12 months of life. There were eight patients with ventricular septal defect, two with total anomalous pulmonary venous return [TAPVR], and the remainders with tetralogy of Fallot, transposition of great arteries [d-TGA], Taussing-Bing malformation, and coronary A-V fistula. The age of the patients ranged from 5 to 12 months, with a mean age of 9.9 months. The mean weight was 6.7 Kg [3.8 to 9.5 KS]. Congestive heart failure persisting despite intensive medical treatment was present In 8 patients [56%], and was the most common indication for operation. Early operation was necessary in 5 of these patients [35%], because of failure to thrive and recurrent pulmonary infection. In one patient with TOF, frequent hypoxic spell prompted the necessity for early operation. In cases of VSD, TAP. VR, TOF, and coronary A-V fistula, Intracardiac repair was done with conventional cardiopulmonary bypass, chemical cold cardioplegia, and topical myocardial cooling. Deep hypothermic circulatory arrest with surface induced cooling, followed by core cooling and core rewarming, was employed .for better exposure in the cases of d-TGA and Taussing-Bing malformation. The results were however, not satisfactory. The overall mortality was 28 per cent. There were no deaths in the eight patients with VSD. The one with coronary A-V fistula survived. The other 5 cases all expired either on the table or immediately after operation. The non-fatal post-operative complications included low cardiac output, respiratory insufficiency, bleeding, and temporary A-V block. The causes of death were prolonged circulatory arrest time in d-TGA, complete A-V block and low cardiac output in TOF and Taussing-Bing malformation and prolonged bypass time and Inadequate correction in TAPVR.

  • PDF

Development of Brightness Correction Method for Mosaicking UAV Images (무인기 영상 병합을 위한 밝기값 보정 방법 개발)

  • Ban, Seunghwan;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1071-1081
    • /
    • 2021
  • Remote Sensing using unmanned aerial vehicles(UAV) can acquire images with higher time resolution and spatial resolution than aerial and satellite remote sensing. However, UAV images are photographed at low altitude and the area covered by one image isrelatively narrow. Therefore multiple images must be processed to monitor large area. Since UAV images are photographed under different exposure conditions, there is difference in brightness values between adjacent images. When images are mosaicked, unnatural seamlines are generated because of the brightness difference. Therefore, in order to generate seamless mosaic image, a radiometric processing for correcting difference in brightness value between images is essential. This paper proposes a relative radiometric calibration and image blending technique. In order to analyze performance of the proposed method, mosaic images of UAV images in agricultural and mountainous areas were generated. As a result, mosaic images with mean brightness difference of 5 and root mean square difference of 7 were avchieved.

The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT (PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가)

  • Kim, Jin-Young;Lee, Seung Jae;jung, Suk;Park, Min-Soo;Kang, Chun-Goo;Im, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose Among various causes that influence image quality degradation, various methods for decrease in Artifact occurred by respiration of patients are being used. Among them, this study intended to evaluate CTAC Shift correction method and additional scan compare to the Scan(Q static scan) using respiratory gated system. Materials and Methods This study was conducted on 10 patients, and used PET-CT Discovery 710 (GE Healthcare, MI, USA) and Varian's RPM system. 5.18 Mbq per kg of $^{18}F$-FDG was injected on patients, asked them to take a rest for 1 hour in the bed, and conducted test after urination. Images were visualized through Q static scan, CTAC Shift correction method, Additional scan based on the Whole body scan(WBS) with Artifact. Decrease in Artifact was compared in each image, conducted Gross Evalution, and measured changes of SUVmax. Results For image obtained through the CTAC Shift correction method through WBS with Artifact, 12~56%, Q static scan image showed 17~54% of change rate and Additional Scan showed -27~46% of change rate. In Blind Test, the CTAC Shift correction image showed the highest point with 4 points, Q static scan image showed 3.5 points, and Additional scan image showed 3.4 points. The standardized WBS scan through Oneway ANOVA and three types of Scan method showed significant difference(p<0.05), and did not show significant difference between the three Scan methods(p>0.05). However, the three Scan methods showed significant difference in Blind test. Conclusion Additional scan and Q static scan require more time than the CTAC Shift correction method, there is concern about excessive exposure to patients by CT rescan and Q static scan is difficult to apply on patients with inconsistent respiration or irregular respiration cycle due to pain. For CTAC Shift correction method, limited correction is possible and the range is limited as well. It is considered as a useful method of improving diagnostic value when hospitals use the system appropriately and develop various advantageous factors of each method.

  • PDF

Measurement of δ-Aminolevulinic Acid in Urine by Fluorometric HPLC and Colorimetric Methods (비색법과 HPLC 법에 의한 요중 δ-Aminolevulinic acid의 측정치 비교)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 1994
  • The urinary excretion of ${\delta}$-aminolevulinic acid has been widely used as a measure of the biological effect of lead in lead exposed workers. It is usually measured by colorimetric method based on the color reaction of ALA-pyrrole with Ehrlich's reagent. But the results of ${\delta}$-ALA in urine by this method are somewhat artificially higher than expected due to the urinary ALA-like compound such as aminoacetone. On the other hand, the recently developed fluorometric HPLC method is very sensitive and specific for the measuring urinary ALA. In order to compare the data obtained by two methods and to investigate the interrelation between two methods, 117 lead workers with different lead exposure were checked urinary ${\delta}$-ALA, blood lead and other lead exposure related indices. The results obtained are as follows; 1. Urinary excretion of ${\delta}$-ALA by colorimetric method is 2.15 times higher than HPLC method in overall, revealing 2.47 times in workers of blood lead less than $20{\mu}g/dl$, 2.53 times in workers of blood lead $21-40{\mu}g/dl$ and 1.86 times in workers of blood lead over $41{\mu}g/dl$, respectively. 2. While the correlation coefficients of ${\delta}$-ALA measured by colorimetric method with blood lead and blood ZPP was 0.571 and 0.629, those of ${\delta}$-ALA measured by HPLC with blood lead and blood ZPP were 0.6l0 and 0.637. All the correlation coefficients were statistically significant, but there was no statistical difference of correlation coefficients between two methods. 3. The correlation coefficient of urinary excretion of ${\delta}$-ALA between two method was 0.838 without any correction, but it was 0.852 with the correction of specific gravity 1.024. 4. Simple linear regression of ${\delta}$-ALA measured by HPLC method on ${\delta}$-ALA measured by colorimetric method was (ALA-UPH)=-0.245+0.536 (ALA-UCO) without any correction and it was (SP ALA)=-0.525+0.598 (SP ALA-UCO) with the correction of specific gravity 1.024. With above results, it is recommended that the diagnostic criteria of ${\delta}$-ALA for lead poisoning needed to be revised if ${\delta}$-ALA is measured by HPLC rather than colorimetric method.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

An investigation of lead absorption in an electric accumulator factory with the use of personal samplers

  • Williams M.K.;King E.;Walford Joan
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02a
    • /
    • pp.561-575
    • /
    • 1994
  • Williams, M K., King, E., and Walford, Joan (1969). Brit. J. industr. Med., 26, 202-216. An investigation of lead absorption in an electric accumulator factory with the use of personal samplers. Thirty-nine lead workers and controls, in stable conditions of exposure, each wore personal lead-in-air samplers daily for two weeks. During the second week samples for blood lead, urinary lead, urinary coproporphyrin, urinary $\gamma$-aminolevulinic acid (ALA), the punctate basophil count, and haemoglobin were taken daily. Duplicate estimations were made on one day. The lead exposures of men doing almost identical jobs differed by ratios of up to four to one. This could be attributed on y to personal differences in working habits. The correlation coefficients and regression equations of the biochemical tests with lead-in-air and with each other were determined. The mean values and $95\%$ confidence limits of single determinations of some of the biochemical tests corresponding to the two commonly accepted TLVs of lead-in-air (0-20 and 0-15 mg./$m^{3}$) were calculated from the regression equations. For each biochemical test the variation due to analytical error, the variation from day to day within subjects and the residual variation about the regression on lead-in-air were calculated. Previous estimates of the latter are not known. Excessive confidence may be placed in an index of exposure due to its low coefficient of variation within subjects unless the coefficient of variation between subjects about regression is taken into account. The correction for specific gravity of estimations of lead and ALA in spot samples of urine was found to reduce slightly the residual variation between subjects about the regression on lead-in-air and to increase the correlations with lead-in-air and with the other biochemical tests, but these changes were not statistically significant. The modified method used for estimating blood lead and urinary lead is described and validated.

  • PDF

Research trends on prevention of heat stroke using clothing: Focusing on practical research in Japan (의복을 활용한 열중증 예방 대책에 관한 연구 동향 조사: 일본의 실용 지향적 연구를 중심으로)

  • Son, Su-Young
    • Human Ecology Research
    • /
    • v.56 no.5
    • /
    • pp.473-491
    • /
    • 2018
  • This study identifies Japanese study content on heat stroke prevention measures using clothes, provides basic data for quantitative wearing assessment studies, presents a developmental direction for those, and helps invigorate further research. Studies were collected concerning clothing-based heat stroke measures in order to analyze the following factors: current status of heat stroke by industry and working environment, heat stroke and body cooling method, clothing microclimate and air circulation in a hot environment, hot environments and wearable sensors, and heat stress reduction and skin exposure. The current WBGT standard does not consider the diversity of wearing clothes according to the working environment. Therefore, it is preferable to add a correction value in consideration of design, materials, and ventilation to prevent heat strokes. For the heat stroke and body cooling method, wearing water-perfused clothing is effective to reduce heat stress and maintain exercise ability. Changing the material and design of clothing or wearing air-conditioned clothing can improve ventilation and the clothing microclimate. However, further evaluation is needed on the effectiveness of air-conditioned clothing as a heat stroke prevention product. The measurement method using a wearable sensor can provide real-time data on the body response due to working in a hot environment. Therefore, it is an effective alarm for heat stroke. Skin exposure area and heat dissipation efficiency should be considered to prevent heat stroke. Reducing the covering area by exposing the head, neck, and limbs, and wearing breathable material can prevent heat stroke from increased body temperature.

Early Resurfacing Using Gastrocnemius Muscle Flap Transposition for Degloving Injury with Exposure of Proximal Tibia (근위부 경골 노출을 동반한 벗겨진 손상의 장딴지 근육 피판을 이용한 조기 피복 치험례)

  • Jeong, Hii Sun;Lee, Hye Kyung
    • Journal of Trauma and Injury
    • /
    • v.21 no.2
    • /
    • pp.140-143
    • /
    • 2008
  • Degloving injuries result from the tangential force against the skin surface, with resultant separation of the skin and the subcutaneous tissue from the rigid underlying muscle and fascia. These injuries are associated with extensive soft tissue loss and occasionally with exposure of bone, and they require reconstructive modality for resurfacing and successful rehabilitation that considers the vascular anatomy and the timing of the operation. A 19-year-old male patient was transferred to our facility with degloving injury extending from the lower third of the right thigh to the malleolar area. The tibial bone was exposed to a size of $2{\times}3.5cm^2$ on the upper third of the lower leg at the posttraumatic third day. The exposed soft tissue was healthy, and the patient did not have any other associated disease. At the posttraumatic sixth day, one-stage resurfacing was performed with a medial gastrocnemius muscle flap transposition for the denuded bone and a split-thickness skin graft for the entire raw surface. The transposed gastrocnemius muscle attained its anatomical shape quickly, and the operating time was relatively short. No transfusion was needed. This early reconstruction prevented the accumulation of chronic granulation tissue, which leads to contracture of the wound and joint. The early correction of the gastrocnemius muscle flap transposition made early rehabilitation possible, and the patient recovered a nearly full range of motion at the injured knee joint. The leg contour was almost symmetric at one month postoperatively.

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF

Correction of Recurrent Ingrowing Toenail Using Partial Matricectomy and Paronychial Advancement Flap (부분기질절제술과 발톱주위전진피판을 이용한 재발성 내증식발톱의 교정)

  • Kim, Eui Sik;Kim, Sung Nam;Noh, Bok Kyun;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • v.33 no.3
    • /
    • pp.347-352
    • /
    • 2006
  • Ingrowing toenail has been treated conventionally by various surgical treatment modlities. However, none of these procedures are perfect to achieve esthetic results with low cost, recurrence, and complication rates. Although mild cases can be treated conservatively, in severe recurrent cases, surgical treatment is preferred. The purpose of this study is to evaluate the effectiveness and safety of using partial matricectomy and paronychial advancement flap for correction of recurrent ingrowing toenail. Eight patients suffering from recurrent ingrowing toenail were operated using partial matricectomy and paronychial advancement flap in our department from August 2004 to August 2005. The number of recurrent episodes ranged from 2 to 5. With digital nerve block, the excision area was marked on nailplate and inflammed lateral nail fold. The horizontally designed paronychial flap considering defect size was effective for wide exposure of the neighboring germinal matrix, which is later to be completely excised or cauterized because remnant germinal matrix made postoperative spicule formation. The nailplate on the affected side was removed about 3-5 mm width longitudinally, being cautious not to damage the proximal dorsal nail fold. The same width of the sterile matrix including germinal matrix was excised longitudinally with inflammed granulation tissue and partial lateral nail fold on the affected side. The subcutaneously elevated paronychial flap was advanced to cover the defect and was anatomically sutured with 5-0 nylon sutures. We evaluated our procedure's effectiveness by examining some factors such as cosmetic results, recurrence, spicule formation, postoperative pain and duration of return to normal activities. In eight patients, no complication was observed such as recurrence, severe pain and spicule formation except for 1 case of infection. Postoperative discomfort was minimal. Average duration of return to normal activities was 12 days. Cosmetically the results were acceptable in all patients. The partial matricectomy and paronychial advancement flap for correction of recurrent ingrowing toenail were found to be technically simple, efficient procedure with a relative low recurrence rate and better cosmetic results.