• Title/Summary/Keyword: Exposure chamber

검색결과 321건 처리시간 0.024초

소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량 (Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions)

  • 장범진;남하윤;신혜민;윤동민;이승국;장인화;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.

Supplementary prenatal copper increases plasma triiodothyronine and brown adipose tissue uncoupling protein-1 gene expression but depresses thermogenesis in newborn lambs

  • Smith, Stephen B.;Sweatt, Craig R.;Carstens, Gordon E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권3호
    • /
    • pp.506-514
    • /
    • 2020
  • Objective: We tested the hypothesis that increasing dietary copper (Cu) to gravid ewes would enhance brown adipose tissue (BAT) thermogenesis in their offspring. Methods: Twin-bearing ewes were assigned on d 70 of gestation to diets containing 3, 10, or 20 ppm dietary Cu (n = 8 per group). Twin lambs were assigned at birth to a cold (6℃) or warm (28℃) environmental chamber for 48 h. Blood was collected from ewes and from lambs and perirenal BAT was collected after 48 h in the environmental chambers. Results: Prenatal Cu exposure increased ewe plasma triiodothyronine (T3) and thyroxine concentration (T4) (p<0.01) but prenatal Cu exposure had no effect on lamb plasma concentrations of T3, T4, glucose, or nonesterified fatty acid concentration (p≥0.08). The high level of prenatal Cu exposure depressed 48-h rectal temperature (p = 0.03). Cold exposure decreased BAT norepinephrine (NE) and increased BAT dopamine (p≤0.01), but prenatal Cu exposure had no effect on BAT cytochrome C oxidase activity or BAT NE or dopamine (p≥0.07). However, BAT of lambs from high-Cu ewes maintained higher uncoupling protein-1 (UCP1) gene expression than BAT of lambs from low- and medium-Cu ewes following warm or cold exposure in environmental chambers (p = 0.02). Cold exposure caused near depletion of BAT lipid by 48 h (p<0.001), increased BAT cytochrome c oxidase activity (p<0.01), and depressed plasma fatty acid concentrations (p<0.001). Conclusion: Although prenatal Cu exposure increased BAT UCP1 expression during warm and cold exposure, prenatal cold Cu exposure depressed 48-h rectal temperature. Cold exposure decreased BAT lipid content by over 80% and decreased lamb plasma fatty acid concentration by over 40%, indicating that fuel reserves for thermogenesis were nearly depleted by 48 h of cold exposure.

이차 에어러솔 생성 잠재력 평가를 위한 Potential Aerosol Mass (PAM) 챔버의 제주도 고산 대기분석 적용 (A Preliminary PAM Measurement of Ambient Air at Gosan, Jeju to Study the Secondary Aerosol Forming Potential)

  • 강은하;;김상우;윤순창;정무현;이미혜
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.534-544
    • /
    • 2011
  • The secondary aerosol forming potential of ambient air was first measured with the Potential Aerosol Mass(PAM) chamber at Gosan supersite on Jeju island from October 22 to November 5, 2010. PAM chamber is a small flowthrough photo-oxidation chamber with extremely high OH and $O_3$ levels. The OH exposure in the PAM chamber was $(2{\pm}0.4){\times}10^{11}{\sim}(6{\pm}1.2){\times}10^{11}$ molecules $cm^{-3}$ s and was similar to 2 to 5 days of aging in the atmosphere. By periodically turning on and off UV lamps in the PAM chamber, ambient aerosol and newly formed aerosol (e.g. called as PAM aerosol) was alternately measured. Aerosol number and mass concentration in the range of 10~487 nm in diameter was measured by SMPS 3034. With UV lamps on, the nucleation mode particles smaller than 50 nm in diameters were formed. Their number concentration was greater than 105 $cm^{-3}$, leading to increase in aerosol mass by 0~8 ${\mu}gm^{-3}$. The variations of PAM and ambient aerosols were greatly dependent on characteristics of air masses such as precursor concentrations and degree of aging. This preliminary results suggests that PAM chamber is useful to assess the aerosol formation potential of air mass and its impact on the air quality. The further analysis of data with gaseous and particulate measurements will be done.

입자 발생 챔버를 이용한 Andersen과 총분진 시료채취기의 특성 비교 (Characteristic comparison of Andersen and total suspended particulate samplers in a particulate matter generation chamber)

  • 박주면
    • 한국산업보건학회지
    • /
    • 제18권3호
    • /
    • pp.177-184
    • /
    • 2008
  • The purpose of this study was to compare the performance characteristics of Andersen and total suspended particulate (TSP) samplers in terms of particle size distribution (PSD) and mass sampling efficiency. In the present study, two Andersen and four TSP samplers were selected and tested to quantitatively estimate human exposure to fly ash representing industrial particulate matter (PM) in a carefully controlled chamber. The PSD characteristics, a mass median aerodynamic diameter and a geometric standard deviation, were found from the sampled PM of airborne samplers in the chamber. An Andersen sampler was compared with a TSP sampler quantified by a coulter counter multisizer, as a reference sampler, to describe the correlation of mass sampling efficiencies between two types of samplers. Overall results indicate that Andersen samplers overestimated small PM due to particle bounce phenomena between impaction stages. There was reasonably good correlation ($R^2$ = 0.89 and 0.91) between the mass sampling efficiencies of Andersen and TSP samplers during the two tests. However, the lower values of slope (0.71 and 0.72) in two tests showed that the Andersen sampler underestimated PM (> AD $10.1\;{\mu}m$) with sufficient inertia due to a relatively lower Andersen inlet velocity at 0.8 m/s comparing with the operating air velocity at 2.1 m/s in the sampling zone of a chamber.

Study of n/γ discrimination using 3He proportional chamber in high gamma-ray fields

  • Choi, Joonbum;Park, Junesic;Son, Jaebum;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.263-268
    • /
    • 2019
  • The $^3He$ proportional chamber is widely used for neutron measurement owing to its high neutron detection efficiency and simplicity for gamma-ray rejection. In general, the neutron and gamma-ray signals obtained from the $^3He$ proportional chamber can be easily separated by the difference in the pulse heights. However, for a high gamma-ray field, the gamma-ray signal cannot be precisely eliminated by the pulse height due to gamma-ray pulse pileup which causes the pulse height of gamma-ray pulse to increase and making the pulses due to neutrons and gamma rays indistinguishable. In this study, an improved algorithm for $n/{\gamma}$ discrimination using a parameter, which is the ratio of the rise time to the pulse height, is proposed. The $n/{\gamma}$ discrimination performance of the algorithm is evaluated by applying it to $^{252}Cf$ neutron signal separation from various gamma-ray exposure rate levels ranging 0.1-5 R/h. The performance is compared to that of the conventional pulse-height analysis method in terms of the gamma elimination ratio. The suggested algorithm shows better performance than the conventional one by 1.7% (at 0.1 R/h) to 70% (at 5 R/h) for gamma elimination.

간접흡연에 노출시킨 흰쥐의 폐조직 손상에 대한 길경의 보호효과 (Effects of Platycodi Radix on Passive Smoking in Rats)

  • 김범회
    • 동의생리병리학회지
    • /
    • 제26권1호
    • /
    • pp.40-46
    • /
    • 2012
  • Cigarette smoking is known to be associated with various chronic pulmonary and cardiovascular diseases ranging from inflammation to cancer. Not only first-hand smoke but also second-hand smoke is suggested to be a factor of health risk. This study was to investigate whether Platycodi Radix extract administration would alter oxidative stress in lung leading to protection of cigarette smoke-induced lung damage. Sprague-Dawley rats were randomly divided into 3 groups; Intact, Smoke+PR and Smoke+Vehicle. In Smoke+PR and Smoke+Vehicle group, the exposure to cigarette smoke was performed for 15 min/day for 4 weeks in ventilated smoking chamber. The Platycodi Radix extract and saline were orally administrated to Smoke+PR and Smoke+Vehicle group each. The rats of Intact group were just kept in ventilated chamber without cigarette smoke. After the experiment for 4 weeks, the lung tissues were collected for histological observation and immunohistochemistry. In Results, airspace enlargement and goblet cell hyperplasia were observed after 4 weeks' exposure to cigarette smoke. Whereas, the oral administration of Platycodi Radix extract for 4 weeks reduced airspace enlargement and goblet cell hyperplasia. Moreover, the alterations of BAX/Bcl-2 proteins in lung tissues were observed. These results suggest that Platycodi Radix extract ameliorates lung damage in cigarette smoke-exposed rats and has protective effects on second-hand smoke injury.

Sprague-Dawley 랫드에서 60일간 용접흄 폭로에 의한 폐기능 변화 (Changes of Pulmonary Function!) During 60 days of Welding Fume Exposure Period 1m Sprague-Dawley Rats)

  • 성재혁;최병길;맹승희;김수진;정용현;한정희;현진숙;송경석;조영봉
    • Toxicological Research
    • /
    • 제20권1호
    • /
    • pp.55-61
    • /
    • 2004
  • Respiratory effects in full time welders include bronchitis, airway irritation, lung function changes, and lung fibrosis. Welder's pneumoconiosis has been generally determined to be benign and not associated with respiratory symptoms based on the absence of pulmonary function abnormalities in welders with marked radiographic abnormalities. Accordingly, to investigate pulmonary function changes during 60 days induced by welding-fume exposure, male Sprague-Dawley rats were exposed to manual metal arc-stainless steel (MMA-SS) welding fumes with concentrations of 64.8$\pm$0.9 mg/$m^3$ (low dose) and 107.8 $\pm$ 2.6 mg/$m^3$ (high dose) total suspended particulates for 2 hr/day, 5 days/week in an inhalation chamber for 60 days. Pulmonary function was measured every week with whole body plethysmograph compensated (WBP Comp, SFT38116, Buxco Electronics, Sharon, CT). The rats exposed to the high dose of welding fumes exhibited statistically significant (p<0.05~0.01) body weight decrease as compared to the control whereas cell number increase of the bronchoalveolar lavage fluid (BALF) (total cell, macrophage, polymorphonuclear cell and lymphocyte) during the 60 days exposure period. And only tidal volume was significantly decreased in dosedependantly during 60 days of MMA-SS welding fume exposure. This pulmonary function change with inflammatory cell recruitment confirms the lung injury caused by the MMA-SS welding fume exposure.

유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구 (The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography)

  • 홍은애;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.11-17
    • /
    • 2013
  • 최근 환자가 안심하고 진료를 받을 수 있도록 의료 환경의 변화에 따라 의료 피폭 저감화 대책이 국내, 국제적으로 추진되고 있다. 연구자는 유방촬영 시 보다 안전하게 검사를 받을 수 있도록 환자의 방사선 피폭에 대한 방어 및 안전 관리가 절실 하다고 생각되어 본 차폐체를 개발하고, 제작하게 되었다. 임상에서 사용 중인 유방촬영 장치로 SID 65 cm, 조건 28 kVp, 63 mAs, 측정기는 Victoreen 6000-529(Fluke Co.)를 이용하여 제작한 Face Block을 사용하여, 환자 30명을 대상으로 실제 갑상샘 위치에 Chamber를 놓고 CC, MLO를 촬영해 Face Block장착 전, 후 선량을 측정하였다. 그 결과 Face Block 장착 후 CC View에서 평균 65.9%의 선량이 감소되었고, MLO View에서는 평균 60.7%의 선량이 감소되었으며, 영상의 질에는 큰 변화가 없었다. 따라서 유방촬영 시 갑상샘의 피폭을 줄이고, 실용적이고, 유용한 실제 Face Block을 개발한 것에 큰 성과가 있었다고 생각되며, 유방촬영 시 환자들의 피폭에 관한 불안감을 해소시켜, 환자 만족도 증대와 함께 환자 피폭선량 경감에 크게 이바지 할 것으로 기대하며, 피폭선량을 줄일 수 있는 방안을 끊임없이 노력해야 할 것이다.

구내 촬영시 방사선사의 안면부 피폭선량 측정 (Facial Exposure Dose Assessment During Intraoral Radiography by Radiological Technologists)

  • 유환;양한준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.195-201
    • /
    • 2014
  • 본 연구에서는 구내 촬영시 방사선작업종사자와 X선관 사이 거리의 증가에 따라 방사선작업종사자의 안면부 피폭선량 감소의 변화를 측정하고자 하였다. 우선 인체조직과 유사한 안면부 Phantom을 제작하였다. 구내 촬영 장치를 이용하여 촬영조건을 성인 상악 대구치부 노출조건 (60kVp, 10mA. 50msec)과 소아 상악 대구치부 노출조건 (60kVp, 10mA, 20msec)으로 설정 하고 방사선작업종사의 안면부의 위치에 Chamber를 고정시켰다. X선 관구와 Phantom을 Chamber로 부터 10cm, 15cm, 20cm, 25cm, 30cm, 35cm, 40cm 위치시킨 후 각 검사조건으로 Phantom을 20회 조사한 후 평균 산란선량을 측정 하였다. 연구 결과 성인 조건으로 조사한 후 감소율은 10cm에서 조사한 산란선량을 기준으로 하였을 때 40cm 에서는 감소율이 7.43%로 약 92.6%가 감소가 되었다. 또한 소아 조건으로 조사한 후 감소율은 10 cm에서 조사한 산란선량을 기준으로 하였을 때 40 cm 에서는 감소율이 2.58 %로 약 97.6%가 감소가 되었다. 결론적으로 치과 방사선 검사 시 방사선 피폭에 대한 방호가 필요할 것으로 사료된다.

Nanoparticle Formation from a Commercial Air Freshener at Real-exposure Concentrations of Ozone

  • Vu, Thai Phuong;Kim, Sun-Hwa;Lee, Seung-Bok;Shim, Shang-Gyoo;Bae, Gwi-Nam;Sohn, Jong-Ryeul
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권1호
    • /
    • pp.21-28
    • /
    • 2011
  • Occupational nanomaterial exposure is an important issue in the manufacture of such products. People are also exposed to various nanoparticles in their living environments. In this study, we investigated nanoparticle formation during the reaction of ozone and volatile organic compounds (VOCs) emitted from a commercial air freshener, one of many widely used consumer products, in a $1-m^3$ reaction chamber. The air freshener contained various VOCs, particularly terpenes. A petri dish containing 0.5 mL of the air freshener specimen was placed in the bottom of the chamber, and ozone was continuously injected into the center of the chamber at a flow rate of 4 L/min with an ozone concentration of either 50, 100 or 200 ppb. Each test was conducted over a period of about 4 h. The higher ozone concentrations produced larger secondary nanoparticles at a faster rate. The amount of ozone reacted was highly correlated with the amount of aerosol formation. Ratios of reacted ozone concentration and of formed particle mass concentration for the three injected ozone concentrations of 50, 100 and 200 ppb were similar to one other; 4.6 : 1.9 : 1.0 and 4.7 : 2.2 : 1.0 for ozone and aerosol mass, respectively.