Comparison of Accuracy and Output Waveform of Devices According to Rectification Method (정류방식에 따른 장치의 정확도와 출력 파형의 비교)

  • Lee, In Ja
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

An ability test for the use of indirect radiographic unit (간접촬영용 X-선 발생장치 성능 평가)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.37-41
    • /
    • 2004
  • Purpose : Raise ability cultivation in presence at a sicked business by performance management estimation of device through measurement. Also Learn a technology that measure exact tube voltage, exposure time, output dose. And it is to grasp photofluorography X-ray generator existing circumstances using at hospital. Material & Method : Investigated Photofluorography X-ray generator(inside, outside each 10) of 10 university hospitals using tube voltage, exposure time, output dose measuring instrument. Result : Photofluorography device that tube voltage correctness is incongruent by examination PAE decision came out 3, and at exposure time correctness examination 2 incongruent, Also 3 that calculate coefficient of variation about exposure in repeatability examination of exposure were incongruent. Inappropriate photofluorography device is 5 outside hospital(mobile unit) and the thing in hospital was 3 in 3 kind of efficiency test. It appeared high that photofluorography device outside hospital is more incongruent than thing in hospital. Conclusion : May ready situation that can offer patient medical service of good quality by radiation exposure reduction, image quality administration, retake decrease etc. by keeping performance of Photofluorography device. Therefore, is considered that need on-time efficiency test.

  • PDF

Potential Exposure to Air Pollutants for Driver and Its Control Using Commercial Air Cleaning Device Inside Vehicle (차량 운전자의 공기오염물질 잠재적 노출 및 차량용 공기청정기에 의한 제어)

  • Kim Dae-Won;Kim Moon-Hyeon;Yang Won-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.481-486
    • /
    • 2004
  • Vehicle occupant exposure to air pollutants has been a subject of concern in recent years because of higher levels of air pollutants inside gasoline or diesel-using vehicle, comparing to the surrounding atmosphere. Contrary to previous studies, fuel of vehicles operated in this study was liquefied petroleum gas (LPG). This study examined the potential exposure and removal efficiency of selected volatile organic compounds (VOCs), nitrogen dioxide ($NO_2$) and respirable suspended particle (RSP) by commercial air cleaning device inside vehicle under different ventilation conditions. Vehicle concentrations inside of benzene, toluene, m,p-xylene, $NO_2$ and RSP were lower under the low ventilation condition. This was indicated that outdoor air pollutants could affect the vehicle air quality inside in case metropolitan cities such as Daegu. The urban vehicle concentrations inside of benzene, toluene, m,p-xylene, $NO_2$ and RSP with air cleaning device were higher than those without air cleaning device. This means that the use of air cleaning device equipped with activated carbon filter, which was used in this study, in the interior of vehicles could be expected to reduce the vehicle occupants exposure to air pollutants effectively. In batch type reactor of laboratory scale, removal efficiencies of air cleaning device used were $97.0\%,\;95.7\%,\;94.6\%\;and\;85.5\%$ respectively in benzene, toluene, m,p-xylene and $NO_2$.

Comparison of Shield of Breast, Thyroid, Eyes for Exposure Dose Reduction in Mammography (유방엑스선검사 시 유방, 갑상샘, 안구 피폭선량 감소를 위한 차폐체 비교)

  • An, Se-Jeong;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.189-194
    • /
    • 2021
  • This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter(OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.

Effects of Long-term Exposure of High and Low Humidity on Thin-film Humidity Sensors

  • Lee, Sang-Wook;Choi, Byung Il;Kim, Jong Chul;Woo, Sang-Bong
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.368-373
    • /
    • 2018
  • The effects of long-term exposure of high and low humidity on thin-film humidity sensors are investigated. Five commercially available thin-film humidity sensors are initially calibrated in a humidity chamber as a reference before longterm exposure to high and low humidity. Then, the sensors are kept in a high-humidity environment (~95 %rh) for four months. After the exposure, the sensors are calibrated in the same manner as the initial calibration. Consequently, the device reading values from the humidity sensors are elevated up to about 5 %rh. Interestingly, the degree of elevation by the high-humidity exposure shows a negative correlation with the price of the humidity sensors. Humidity sensors are then kept in a low-humidity environment (~10 %rh) for another four months. After the exposure, a calibration similar to the initial calibration is performed. As a result, the device reading from humidity sensors is decreased, indicating a recovery from the effect of high-humidity exposure. The durability test conducted in this study provides experimental evidence for the use of thin-film humidity sensors in high-humidity environments such as greenhouses and food factories for a long period of time.

Investigation of Oxygen Functional Group Movement in Graphene Oxide Devices (그래핀 산화물 소자에서의 산소 작용기 이동 연구)

  • Eun Hee Kee;Mohd Musaib Haidari;Ji Hoon Jeon;Jin Sik Choi;Bae Ho Park
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.100-104
    • /
    • 2023
  • In this study, a device was fabricated to check the possibility of a memory device by controlling the oxygen functional groups in graphene oxide formed with a 45-second exposure time. We discovered that graphene oxide can be formed using the ultraviolet (UV) light treatment method with different exposure times. Moreover, Raman spectroscopy measurement revealed that the oxygen functional groups can be moved by controlling the voltage. We further studied the change in the local graphene oxide region, which was found to be related to the modulation of the electrical properties of the device. Therefore, the fabricated graphene oxide device can be used as a wettability switching membrane and graphene-based ion transport device.

Evaluation of radiological safety according to accident scenarios for commercialization of spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2606-2613
    • /
    • 2022
  • Spent resin often exceeds radiation limits for safe disposal, creating a need for commercial-scale treatment techniques to reduce resin radioactivity. In this study, the radiological safety of a commercialized spent resin treatment device with a treatment capacity of 1 ton/day was evaluated. The results confirm that the device is radiologically safe in the event of an accident. This device desorbs 14C from the spent resin, allowing disposal as low-level waste instead of intermediate-level waste. The device also reduces overall waste by recycling the extracted 14C. Potential accident scenarios were explored to enable dose assessments for both internal and external exposure while preventing further spillage of the device and processing the spilled resin. The scenarios involved the development of a surface fracture on the resin mixture separator and microwave systems, which were operated under pressure and temperature of 0-6 bar and 0-150 ℃, respectively. In the case of accidents with separator and microwave device, the maximum allowable working time of worker were derived, respectively, considering external and internal exposures. When wearing the respirator corresponding to APF 50, in the case of the microwave device accident scenario, the radiological safety was confirmed when the maximum worker worked within 132.1 h.

Effects of Various Laser Wavelengths and Power Densities on the Ocular Damage in Pigmented Rats

  • Chung, Phil-Sang;Shin, Jang-In;Chang, Moo-Hwan;Chang, So-Young;Kang, Jung-Wook;Hwang, Hee-Jun;Ahn, Jin-Chul
    • Biomedical Science Letters
    • /
    • v.14 no.3
    • /
    • pp.173-178
    • /
    • 2008
  • With the widespread use of laser in medical and industrial settings, the incidence of laser injury to the ocular continues to grow among workers involved in handling lasers. The aim of this study is to compare ocular damages after irradiation with various laser wavelengths and power density. Ocular of pigmented rats was irradiated with $CO_2$ laser, 1064 nm Nd:YAG laser, and 532 nm diode laser. We observed damage of cornea, lens, and retina using slit lamp microscope and funduscopy. H&E staining of histopathology were applied to study the specimens. The higher exposure ($200mW/cm^2$, 10 sec) with $CO_2$ laser resulted in severe damage at the cornea. For the 1064 nm Nd:YAG laser, the higher exposure than $10mW/cm^2$ (10 sec) resulted in damage at the cornea and lens. Further, with the 532 nm diode laser, retinal lesions were induced when $10mW/cm^2$ (0.25 sec) was delivered to the eye. Theses results suggest that the ocular damages are different from various laser wavelength and power density.

  • PDF

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

Usefulness of Non-Invasive Measurement Tool on Performance Evaluation of Inverter Type X-ray Unit (인버터식 X선장치의 성능평가 시 비접속형 측정기의 유용성)

  • Kang, Se-Sik;Kim, Chang-Soo;Ko, Sung-Jin
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.123-127
    • /
    • 2008
  • Purpose: As the demand of a simple and precise method increases to evaluate the performance of the inverter type x-ray unit, we evaluated the usefulness of the recently-introduced X-ray Multi-Function Test Device (moldel : Xi (unfors)-prestige). Method: We compared the performance of X-ray Multi-Function Test Device (XMFTD) which is non-inveasive type device with the performance of Dynalyzer III that has been most widely used inveasive type measure device. Result: X-ray output dose was increased a little in the XMFTD, but both devices were below the performance evaluation standard, 0.002 in the output reproducibility. Linearity of XMFTD were below 0.1 which means that Dynalyzer III showed more excellency in linearity. As the the accuracy of exposure factor, 1.8 and 2 tube voltage, 2.01 and 2.3 tube current were measured. The exposure time was also measured by 0.01 sec ${\pm}10%$. Both devices were within the acceptance of performance evaluatioin standard. Conclusion: We proved the usefulness of X-ray Multi-Function Test Device (model: Xi (unfors)-prestige) to evaluated the performance on reproductibility and linearity of X-ray output and accuracy of exposure factor of inverter type unit.

  • PDF