• Title/Summary/Keyword: Explosion hazards

Search Result 112, Processing Time 0.03 seconds

Measurement and Prediction of the Flash Point for the Flammable Binary Mixtures using Tag Open-Cup Apparatus (Tag식 개방계 장치를 이용한 가연성 이성분계 혼합물의 인화점 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sungjin;Song, Young-Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.181-185
    • /
    • 2005
  • The flash point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of industrial material. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The flash points for the n-butanol+n-propionic acid and n-propanol+n-propionic acid systems were measured by using Tag open-cup apparatus(ASTM D 1310-86). The experimental data were compared with the values calculated by the laws of Raoult and van Laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.

A Study of Structural Response of Pipes due to Internal Gaseous Detonation of Hydrogen- and Hydrogen-Air Mixtures (수소와 탄화수소 계열 연료의 비정상 연소에 의한 파이프 변형 연구)

  • Kim, Dae-Hyun;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.11
    • /
    • pp.1094-1103
    • /
    • 2008
  • A fuel specific detonation wave in a pipe propagates with a predictable wave velocity. This internal detonation wave speed determines the level of flexural wave excitation of pipes and the possibility of resonant response leading to a large displacement. In this paper, we present particular solutions of displacements and the resonance conditions for internally loaded pipe structures. These analytical results are compared to numerical simulations obtained using a hydrocode(multi-material blast wave analysis tool). We expect to identify potential explosion hazards in the general power industries.

Characteristics of Burn Types, Causes, and Treatment in Hospitalized Female Patients with Industrial Injuries (화상으로 입원한 여성 근로자의 화상유형 및 발생원인, 치료적 특성)

  • Kim, Ji-Na;Kang, Hee Sun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.25 no.2
    • /
    • pp.85-95
    • /
    • 2016
  • Purpose: The purpose of this study was to examine the burn characteristics of female patients hospitalized in a burn center. Methods: This is a retrospective descriptive study. The subjects were 222 female patients aged over 19 years old having burn injuries from work sites between January 1, 2012 and December 31, 2014. Data were collected using electronic medical records about the burn-related characteristics. The data were analyzed descriptively. Results: Many of the subjects were in their forties and fifties. Most subjects showed burns with an area of less than 10% of the body surface with a severity of second degree. Scalding burns were the most frequent. Contact burns were usually of third-degree severity and occurred on hands and wrists. Flame burns affected the largest body surface area and frequently occurred on the face and mainly caused by explosion of a stove or kitchen gas. Chemical burns frequently occurred on the lower limbs. Conclusion: Female workers are exposed to the hazards of burn injuries in industrial accidents. Types of burn differ depending on the workplace conditions. Therefore, preventative measures for burn injuries should be established in accordance with the characteristics of each industry to which female workers belong.

Properties Evaluation of Thermochromic Gel Compounds for Detecting Overheating (과열감지용 열변색 겔성형체의 특성 평가)

  • Kim, Jeong-Hun;Cho, Myoung-Ho;Kang, Young-Goo
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.61-66
    • /
    • 2008
  • In this research, gel compounds containing thermochromic ingredients were manufactured and evaluated to prevent the transition hazards of fire and explosion, which they are one of the methods for detecting abnormal conditions caused by overheating of special materials early. And also, compounds of viscoelastic and brushing types were manufactured as the kind and content of raw materials, and manufacturing process to enlarge the application for overheat-detecting targets. Test methods were conducted as chromism test, viscosity profile, starting time of thermochromism, and FT-IR analysis. Thermochromic gel materials exhibit chromism properties that can detect abnormal conditions effectively, and then they are possible to various applications.

Measurement of Flash Point for Binary Mixtures of Methanol, Ethanol, 1-propanol and Toluene (Methanol, Ethanol, 1-propanol 그리고 Toluene 이성분 혼합계에 대한 인화점 측정)

  • Hwang, In Chan;Kim, Seon Woo;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The flash point is one of the most important parameters used to characterize the ignition and explosion hazards of liquids. Flash points were measured for several binary systems containing toluene, including {methanol+toluene}, {ethanol+toluene}, and {1-propanol+toluene}. Experiments were performed according to the standard test method using a SETA closed cup flash point tester. The measured flash points were compared with the predicted values calculated using the following $G^E$ models: Wilson, NRTL, and UNIQUAC. The average absolute deviation between the predicted and measured lower flash point was less than 1.69 K.

Multivariate Statistical Analysis and Prediction for the Flash Points of Binary Systems Using Physical Properties of Pure Substances (순수 성분의 물성 자료를 이용한 2성분계 혼합물의 인화점에 대한 다변량 통계 분석 및 예측)

  • Lee, Bom-Sock;Kim, Sung-Young
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.13-18
    • /
    • 2007
  • The multivariate statistical analysis, using the multiple linear regression(MLR), have been applied to analyze and predict the flash points of binary systems. Prediction for the flash points of flammable substances is important for the examination of the fire and explosion hazards in the chemical process design. In this paper, the flash points are predicted by MLR based on the physical properties of pure substances and the experimental flash points data. The results of regression and prediction by MLR are compared with the values calculated by Raoult's law and Van Laar equation.

  • PDF

Applicability of CO2 Extinguishing System for Ships (질식사고 방지용 CO2 소화설비의 선박 적용성)

  • Ha, Yeon Chul;Seo, Jung Kwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.4
    • /
    • pp.294-300
    • /
    • 2017
  • The offshore installations and ships are the structures most likely to be exposed to hazards such as hydrocarbon fire and/or explosion. Developing proactive measures to prevent the escalation of such events thus requires detailed knowledge of the related phenomena and their consequences. $CO_2$ extinguishing systems are extensively used for fire accidents of on-and offshore installations because of outstanding performance and low cost. There is, however, the risk of carbon dioxide system which enumerates many of the fatalities by suffocation associated with industrial fire protection requirements. Therefore, the aim of this study is to perform the prediction of fire suppression characteristics of the carbon dioxide system in realistic enclosed compartment area of ships and propose $CO_2$ extinguish fire fighting system for preventing suffocation accidents during fire fighting. According to CFD calculations, it can be observed and assessed that various fire profiles with $CO_2$ and $O_2$ mole fraction in the target enclosed compartment area are applicable within the proposed system. Additionally, the design of fire safety system of ships and offshore installations can utilize ventilation system and/or layout arrangement through the proposed system.

A Study on the Characteristics & Fire Hazard of Electric Range (전기레인지의 특성과 화재 위험성에 관한 연구)

  • Lee, Jung-Il;Ha, Kag-Cheon;Kim, Ji-Myong
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.380-390
    • /
    • 2019
  • Purpose: Recently, in addition to increase in the use of electric ranges, fires have also been increasing. Method: To find out the fire risk of induction and highlights range, looked at the structure and operation methods. Combustion tests, heat transfer tests, and ignition tests were performed on both types. Results: The highlight electric range burned the towel two minutes later, takes about 25 minutes for the residual heat to cool down after cooking, and the energy of the red color disappeared in three to four minutes and no sparks were seen. Conclusion: Experiments have shown that burn and fire hazards exist, especially if there is cracks in the top, there is a risk of fire and explosion.

Flash Point Measurement of n-Propanol+n-Hexanol and n-Butanol+n-Hexanol Systems Using Seta Flash Closed Cup Tester (Seta Flash 밀폐식 장치를 이용한 n-Propanol+n-Hexanol계와 n-Butanol+n-Hexanol계의 인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.34-39
    • /
    • 2019
  • Flash point is the important indicator to determine fire and explosion hazards of liquid solutions. In this study, flash points of n-propanol+n-hexanol and n-butanol+n-hexanol systems were obtained by Seta flash tester. The methods based on UNIFAC equation and multiple regression analysis were used to calculate flash point. The calculated flash point was compared with the experimental flash point. Absolute average errors of flash points calculated by UNIFAC equation are $2.9^{\circ}C$ and $0.6^{\circ}C$ for n-propanol+n-hexanol and n-butanol+n-hexanol, respectively. Absolute average errors of flash points calculated by multiple regression analysis are $0.5^{\circ}C$ and $0.2^{\circ}C$ for n-propanol+ n-hexanol and n-butanol+n-hexanol, respectively. As can be seen from AAE, the values calculated by multiple regression analysis are noticed to be better than the values by the method based on UNIFAC eauation.

Surface modified ceramic fiber separators for thermal batteries

  • Cheong, Hae-Won;Ha, Sang-Hyeon;Choi, Yu-Song
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.308-311
    • /
    • 2012
  • A wide range of possible hazards existing in thermal batteries are mainly caused by thermal runaway, which results in overheating or explosion in extreme case. Battery separators ensure the separation between two electrodes and the retention of ion-conductive electrolytes. Thermal runaways in thermal batteries can be significantly reduced by the adoption of these separators. The high operating temperature and the violent reactivity in thermal batteries, however, have limited the introduction of conventional separators. As a substitute for separators, MgO powders have been mostly used as a binder to hold molten salt electrolyte. During recent decades the fabrication technology of ceramic fiber, which has excellent mechanical strength and chemical stability, has undergone significant improvement. In this study we adopted wet-laid nonwoven paper making method instead of the electrospinning method which is costly and troublesome to produce in volume. Polymeric precursor can readily be coated on the surface of wet-laid ceramic paper, and be formed into ceramic film after heat treatment. The mechanical strength and the thermo-chemical stability as well as the wetting behaviors of ceramic separators with various molten salts were investigated to be applicable to thermal batteries. Due to their excellent chemical, mechanical, and electrical properties, wet-laid nonwoven separators made from ceramic fibers have revealed positive possibility as new separators for thermal batteries which operate at high temperature with no conspicuous sign of a short circuit and corrosion.