• 제목/요약/키워드: Experimental verification

검색결과 1,663건 처리시간 0.027초

국제 열핵융합실험로 펄스전원계통의 무효전력보상기 검증 (Reactive Power Compensator for Pulsed Power Electric Network of International Thermonuclear Experimental Reactor)

  • 조현식;조종민;차한주
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.290-295
    • /
    • 2015
  • Analysis and verification of reactive power compensator (RPC) for ITER pulsed power electric network (PPEN) are described in this paper. The RPC system is rated for a nominal power of 250 Mvar necessary to comply with the allowable reactive power limit value from the grid 200 Mvar. This system is currently under construction and is based on static var compensation technology with a thyristor-controlled reactor and a harmonic filter. The RPC minimizes reactive power from grid using prediction of reactive power consumption of AC-DC converters. The feasibility of the reactive power compensation was verified by assembling a real controller and implementing ITER PPEN in the real time digital simulator for the hardware-in-loop facility. When maximum reactive power is reached, grid voltage is stabilized and maximum reactive power decreased from 120 Mvar to 40 Mvar via the reactive power prediction method.

고효율 및 고전력밀도 3-레벨 LLC 공진형 컨버터 (High-Efficiency and High-Power-Density 3-Level LLC Resonant Converter)

  • 구현수;김효훈;한상규
    • 전력전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.153-160
    • /
    • 2018
  • Recent trends in high-power-density applications have highlighted the importance of designing power converters with high-frequency operation. However, conventional LLC resonant converters present limitations in terms of high-frequency driving due to switching losses during the turn-off period. Switching losses are caused by the overlap of the voltage and current during this period, and can be decreased by reducing the switch voltage. In turn, the switch voltage can be reduced through a series connection of four switches, and additional circuitry is essential for balancing the voltage of each switch. In this work, a three-level LLC resonant converter that can operate at high frequency is proposed by reducing switch losses and balancing the voltages of all switches with only one capacitor. The voltage-balancing principle of the proposed circuit can be extended to n-level converters, which further reduces the switch voltage stress. As a result, the proposed circuit is applicable to high-input applications. To confirm the validity of the proposed circuit, theoretical analysis and experimental verification results from a 350 W-rated prototype are presented.

화자인식 알고리즘을 이용한 보안 시스템 구축 (An Implementation of Security System Using Speaker Recognition Algorithm)

  • 신유식;박기영;김종교
    • 전자공학회논문지T
    • /
    • 제36T권4호
    • /
    • pp.17-23
    • /
    • 1999
  • 본 연구는 문맥 독립형 화자 인식 알고리즘을 이용하여 보안시스템을 소프트웨어와 하드웨어로 구성한 논문이다. 화자인식을 이용한 보안시스템은 윈도우상에서 사운드카드를 이용하여 음성을 입력받고, 성도 모델링을 이용한 음성 파라미터를 추출하였으며, k-means 클러스터링 알고리즘을 기반으로 하여 화자를 모델링하였다. 등록된 화자에 대한 인식된 결과는 PIC16F84 마이크로 프로세서를 이용하여 자물쇠를 개${\cdot}$폐하도록 구성하였다. OFF-LINE의 실험은 TIMIT데이터를 이용하였으며, 5명의 화자에 대하여 ON-LINE으로 인식한 결과 학습시킨 데이터에 대해서는 100%의 인식률을 얻었으며 학습을 시키지 않은 데이터에 대해서는 99%의 인식률을 얻었다. 그리고 사용자 거부율 1%, 사칭자 허용률 0%, 검증평균오류는 0.5%를 보였다.

  • PDF

Theoretical Calculation and Experimental Verification of the Hf/Al Concentration Ratio in Nano-mixed $Hf_xAl_yO_z$ Films Prepared by Atomic Layer Deposition

  • Kil, Deok-Sin;Yeom, Seung-Jin;Hong, Kwon;Roh, Jae-Sung;Sohn, Hyun-Cheol;Kim, Jin-Woong;Park, Sung-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권2호
    • /
    • pp.120-126
    • /
    • 2005
  • We have proposed a characteristic method to estimate real composition when multi component oxide films are deposited by ALD. Final atomic concentration ratio was theoretically calculated from the film densities and growth rates for $HfO_2$ and $Al_2O_3$ using ALD processed HfxAhOz mms.W e have transformed initial source feeding ratio during deposition to fins] atomic ratio in $Hf_xAl_yO_z$ films through thickness factors ($R_{HFO_2}$ ami $R_{Al_2O_3}$) ami concentration factor(C) defined in our experiments. Initial source feeding ratio could be transformed into the thickness ratio by each thickness factor. Final atomic ratio was calculated from thickness ratio by concentration factor. It has been successfully confirmed that the predicted atomic ratio was in good agreement with the actual measured value by ICP-MS analysis.

특수 및 준특수 상세에 따른 철근콘크리트 전단벽의 비선형 내진거동 해석 (Analysis of Nonlinear Seismic Behavior of Reinforced Concrete Shear Wall Systems Designed with Special and Semi-Special Seismic Details)

  • 윤성준;이기학;천영수;김태완
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.43-51
    • /
    • 2013
  • In this paper, analytical models for reinforced concrete shear wall systems designed based on Korean Building Code (KBC2009) are proposed, which have special and semi-special seismic details and are compared with experimental results for a verification of analytical models. In addition, semi-special seismic details aimed to improve constructability and enhance economic efficiency were proposed and evaluated. The analytical models were performed based on nonlinear static and dynamic analysis. Through the nonlinear analyses, two seismic details showed the similar seismic behavior from the cyclic test and the analytical models for the two different seismic details represented the behavior in terms of the initial stiffness, maximum strength and strength degradation. And newly proposed seismic details(semi-special) provided with similar hysterestic behavior as well as the maximum drift.

비폭력대화(NVC)모델에 근거한 포괄적 성교육 프로그램의 개발 및 평가 (Development and Evaluation of a Comprehensive Sex Education Program Based on Nonviolent Communication Model)

  • 강현진;김주희
    • 동서간호학연구지
    • /
    • 제26권1호
    • /
    • pp.80-90
    • /
    • 2020
  • Purpose: Sex education should be given priority to address dating violence. Comprehensive sex education has been developed based on a nonviolent communication model between couples for the smooth resolution of problems with the opposite sex. The purpose of this study was to develop and apply Comprehensive Sex Education for unmarried couples in their 20s-30s and to examine the effects on sex communication, problem-solving communication, and relationship competence. Methods: This study developed a total of six web-based sex education sessions. A comprehensive sex education program combined with nonviolent communication between couples was developed based on the UNESCO Sex Education Guidelines. A pre- and post-equivalence control design was used to provide moderation-based sex education to compare the effects on gender communication, communication dissatisfaction, and relationship development. Results: We developed a comprehensive sex education program for couples that took three minutes per episode, on a web-based basis. Sex communication, problem-solving communication, and love relationship competence showed significant pre- and post-test differences between the experimental and control groups. Conclusion: The program of this study is an attempt to introduce Korea to comprehensive sex education, which has already been shown to be effective through numerous verification processes abroad and will provide assistance in forming future relationships between lovers.

렌지후드의 성능개선을 위한 시로코 팬 주위의 유동해석 (PERFORMANCE IMPROVEMENT OF A RANGE HOOD SIROCCO FAN BY CFD FLOW ANALYSIS)

  • 한병윤;박진우;이명수;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.159-165
    • /
    • 2008
  • A sirocco fan is widely used for discharging pollutants of a kitchen space since it is able to generate a relatively high air flow rate considering its small size and makes less noise than a axial fan or a centrifugal fan. However, it has a problem because its efficiency is low, and power consumption is larger. Performance of a sirocco fan is influenced by various factors such as number of the fan blades, diameter of the fan, geometry of the fan, geometry of its housing, revolution frequency, static pressure condition, and etc. This research investigated the effect on the performance of geometry of the housing. For CFD analysis, we used a commercial code, SC/Tetra, and used a sliding mesh method to give the same condition as an actual state. Verification of the CFD results is done by comparison of experimental data and numerical one about the suction flow rate, and it is confirmed that two results are well consistent. After we changed the shape of housing according to Archimedes' screw, we observed that suction efficiency is improved by 10.7% maximum.

  • PDF

유연 혈관에서 유체-고체 상호작용에 대한 유한요소 해석 (Finite element analysis of the fluid-structure interaction in a compliant vessel)

  • 심은보;고형종
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.591-596
    • /
    • 2000
  • Flow through compliant tubes with linear taper in wall thickness is numerically simulated by finite element analysis. Two models are examined: a planar two-dimensional channel, and an axisymmetric tube. For verification of the numerical method, flow through a compliant stenotic vessel is simulated and compared to existing experimental data. Computational results for an axisymmetric tube show that as cross-sectional area falls with a reduction in downstream pressure, flow rate increases and reaches a maximum when the speed index (mean velocity divided by wave speed) is near unity at the point of minimum cross-section area, indicative of wave speed flow limitation or "choking" (flow speed equals wave speed) in previous one-dimensional studies. For further reductions in downstream pressure, flow rate decreases. Cross-sectional narrowing is significant but localized. When the ratio of downstream-to-upstream wall thickness is ${\le}$ 2 the area throat is located near the downstream end; as wall taper is increased to ${\ge}$ 3 the constriction moves to the upstream end of the tube. In the planar two-dimensional channel, area reduction and flow limitation are also observed when outlet pressure is decreased. In contrast to the axisymmetric case, however, the elastic wall in the two-dimensional channel forms a smooth concave surface with the area throat located near the mid-point of the elastic wall. Though flow rate reaches a maximum and then falls, the flow does not appear to be choked.

  • PDF

Mobility Improvement of an Internet-based Robot System Using the Position Prediction Simulator

  • Lee Kang Hee;Kim Soo Hyun;Kwak Yoon Keun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권3호
    • /
    • pp.29-36
    • /
    • 2005
  • With the rapid growth of the Internet, the Internet-based robot has been realized by connecting off-line robot to the Internet. However, because the Internet is often irregular and unreliable, the varying time delay in data transmission is a significant problem for the construction of the Internet-based robot system. Thus, this paper is concerned with the development of an Internet-based robot system, which is insensitive to the Internet time delay. For this purpose, the PPS (Position Prediction Simulator) is suggested and implemented on the system. The PPS consists of two parts : the robot position prediction part and the projective virtual scene part. In the robot position prediction part, the robot position is predicted for more accurate operation of the mobile robot, based on the time at which the user's command reaches the robot system. The projective virtual scene part shows the 3D visual information of a remote site, which is obtained through image processing and position prediction. For the verification of this proposed PPS, the robot was moved to follow the planned path under the various network traffic conditions. The simulation and experimental results showed that the path error of the robot motion could be reduced using the developed PPS.

고주파 유도가열을 이용한 열간 파이프 벤딩 공정 설계 (Process Design of the Hot Pipe Bending Process Using High Frequency Induction Heating)

  • 류경희;이동주;김동진;김병민;김광호
    • 한국정밀공학회지
    • /
    • 제18권9호
    • /
    • pp.110-121
    • /
    • 2001
  • During hot pipe bending using induction heating, the wall of bending outside is thinned by tensile stress. In design requirement, the reduction of wall thickness is not allowed to exceed 12.5%. So in this study, two methods of bending, one is loading of reverse moment and the other is loading of temperature gradient, have been investigated to design pipe bending process that satisfy design requirements. For this purpose, finite element analysis with a bending radius 2Do(outer diameter of pipe) has been performed to calculate proper reverse moment and temperature gradient to be applied. Induction heating process has been analyzed to estimate influence of heating process parameters on heating characteristic by finite difference method. Then pipe bending experiments have been performed for verification of finite element and finite difference analysis results. Experimental results are in good agreement with the results of simulations.

  • PDF