• Title/Summary/Keyword: Experimental time

Search Result 16,992, Processing Time 0.038 seconds

Development, implementation and verification of a user configurable platform for real-time hybrid simulation

  • Ashasi-Sorkhabi, Ali;Mercan, Oya
    • Smart Structures and Systems
    • /
    • v.14 no.6
    • /
    • pp.1151-1172
    • /
    • 2014
  • This paper presents a user programmable computational/control platform developed to conduct real-time hybrid simulation (RTHS). The architecture of this platform is based on the integration of a real-time controller and a field programmable gate array (FPGA).This not only enables the user to apply user-defined control laws to control the experimental substructures, but also provides ample computational resources to run the integration algorithm and analytical substructure state determination in real-time. In this platform the need for SCRAMNet as the communication device between real-time and servo-control workstations has been eliminated which was a critical component in several former RTHS platforms. The accuracy of the servo-hydraulic actuator displacement control, where the control tasks get executed on the FPGA was verified using single-degree-of-freedom (SDOF) and 2 degrees-of-freedom (2DOF) experimental substructures. Finally, the functionality of the proposed system as a robust and reliable RTHS platform for performance evaluation of structural systems was validated by conducting real-time hybrid simulation of a three story nonlinear structure with SDOF and 2DOF experimental substructures. Also, tracking indicators were employed to assess the accuracy of the results.

Time-frequency analysis of reactor neutron noise under bubble disturbance and control rod vibration

  • Yuan, Baoxin;Guo, Simao;Yang, Wankui;Zhang, Songbao;Zhong, Bin;Wei, Junxia;Ying, Yangjun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1088-1099
    • /
    • 2021
  • Time-frequency analysis technique is an effective analysis tool for non-stationary processes. In the field of reactor neutron noise, the time-frequency analysis method has not been thoroughly researched and widely used. This work has studied the time-frequency analysis of the reactor neutron noise experimental signals under bubble disturbance and control rod vibration. First, an experimental platform was established, and it could be employed to reactor neutron noise experiment and data acquisition. Secondly, two types of reactor neutron noise experiments were performed, and valid experimental data was obtained. Finally, time-frequency analysis was conducted on the experimental data, and effective analysis results were obtained in the low-frequency part. Through this work, it can be concluded that the time-frequency analysis technique can effectively investigate the core dynamics behavior and deepen the identification of the unstable core process.

Calculation of Gauge Precisions by Measurement Experimental Design for Split Split Plots (2단분할법 측정 실험계획에 의한 게이지 정밀도 산정)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.649-657
    • /
    • 2009
  • The paper presents the measurement split split-plot models for saving the time and cost. The split split-plot designs developed are efficiently used to estimating the gauge R&R(Reproducibility & Repeatability) when the completely randomized design of all factors(such as high pressure and temperature) is expensive and time consuming. The models studied include three split split-plots considering the type of experimental units.

  • PDF

Different Real Time PCR Approaches for the Fine Quantification of SNP's Alleles in DNA Pools: Assays Development, Characterization and Pre-validation

  • Mattarucchi, Elia;Marsoni, Milena;Binelli, Giorgio;Passi, Alberto;Lo Curto, Francesco;Pasquali, Francesco;Porta, Giovanni
    • BMB Reports
    • /
    • v.38 no.5
    • /
    • pp.555-562
    • /
    • 2005
  • Single nucleotide polymorphisms (SNPs) are becoming the most common type of markers used in genetic analysis. In the present report a SNP has been chosen to test the applicability of Real Time PCR to discriminate and quantify SNPs alleles on DNA pools. Amplification Refractory Mutation System (ARMS) and Mismatch Amplification Mutation Assay (MAMA) has been applied. Each assay has been pre-validated testing specificity and performances (linearity, PCR efficiency, interference limit, limit of detection, limit of quantification, precision and accuracy). Both the approaches achieve a precise and accurate estimation of the allele frequencies on pooled DNA samples in the range from 5% to 95% and don't require standard curves or calibrators. The lowest measurement that could be significantly distinguished from the background noise has been determined around the 1% for both the approaches, allowing to extend the range of quantifications from 1% to 99%. Furthermore applicability of Real Time PCR assays for general diagnostic purposes is discussed.

Implementation and Experimental Evaluation of Bandwidth Allocation Scheme on PROFIBUS (PROFIBUS에서 대역폭 할당 기법 구현 및 실험적 평가)

  • Hong, Seung-Ho;Kim, Yu-Chul;Kim, Ji-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.11
    • /
    • pp.943-954
    • /
    • 2000
  • Fieldbus is the lowest level industrial network in the communication hierarchy of factory automation and distributed process control systems. Data generated from field devices are largely divided into three categories : time-critical, periodic and time-available data. Because these data share one fieldbus medium, it needs a method that allocates these data to the bandwidth-limited fieldbus medium. This paper introduces an implementation method of bandwidth allocation scheme on PROFIBUS. In order to implement bandwidth allocation scheme on PROFIBUS, the following functions need to be supplemented on the FDL(Fieldbus Datalink Layer) protocol: (i) separation of medium bandwidth into periodic and non-periodic intervals, (ii) synchronization of node timers over a local link. In order to examine the validity of bandwidth allocation scheme on PROFIBUS, this paper develops an experimental model of a network system. The results obtained from the experimental model show that the bandwidth allocation scheme satisfies the performance requirement of time-critical, periodic and time-available data.

  • PDF

Evaluation of Shortening the Stay Time of Patients in an Emergency Medical Center (EMC) (응급실 환자의 응급의료센터 체류시간 단축프로그램 개발 및 효과)

  • Kim, Eun-Joo;Lim, Ji-Young
    • Journal of Home Health Care Nursing
    • /
    • v.17 no.1
    • /
    • pp.21-27
    • /
    • 2010
  • Purpose: The study evaluated a program to shorten EMC stay time. Methods: The subjects were EMC patients, and comprised a control group of 8,477 and an experimental group of 8,378. Data were collected from June 2006 to August 2007, and analyzed concerning stay time for doctor visit, decision making, and discharge. The data were analyzed by $X^2$-test and ANCOVA using SPSS14.0. Result: The stay time of doctor visit, decision making and discharge of the experimental group was significantly less compared to the control group. Using second and third grade triage criteria, the stay time of experimental group was statistically reduced from the control. Conclusion: The implemented shortening program was effective in reducing EMC stay time and increasing EMC effectiveness.

  • PDF

Awareness effects by aquapuncture with dexamethasone in tiletamine/zolazepam anesthetized dogs

  • Park, Hyung-Jin;Song, Kun-Ho;Kim, Duck-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.4
    • /
    • pp.303-307
    • /
    • 2011
  • Awareness effect of aquapuncture with dexamethasone on GV-26 was studied in tiletamine/zolazapam anesthetized six healthy crossbred dogs using a randomized cross-over experimental study design. After anesthesia by tiletamine/zolazapam, 0.1 mg dexamethasone was injected on GV-26 at 20 min in the experimental group. For the control group, 0.1 mg dexamethasone was injected on the quadriceps femoralis. A significant difference was evident in the sedation score between groups at 60 and 90 min (p < 0.05). A significant difference was also evident in the analgesia score at 50 and 60 min (p < 0.05). At 90 min, all dogs in the experimental group responded strongly to pain (p < 0.01). Head up time, sternal recumbent time, standing time, and walking time was shorter in the experimental group, but the difference from the control group was statistically significant only for head up time and walking time (p < 0.05). GV-26 acupuncture with dexamethasone is useful for awareness effects after anesthesia.

SHEAR BOND STRENGTH OF DENTIN BONDING AGENTS ON DENTIN SURFACE TREATED WITH EUGENOL (유지놀 처리된 상아질 표면의 상아질 접착제의 전단결합강도에 관한 연구)

  • Yu, Hwa-Sung;Choi, Gi-Woon;Choi, Kyung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.550-560
    • /
    • 2000
  • In this study, shear bond strength of two bonding systems were measured and appearance of dentin surfaces were observed with SEM according to the storage time of eugenol on dentin surface, thus evaluated the effect of eugenol on bond strength of two dentin bonding systems. Control groups were directly bonded to dentin surface with One Step, Prime & Bond 2.1. Experimental groups were divided into experimental I and II according to dentin bonding agents. After eugenol application, dentin surfaces were bonded with One Step and Prime & Bond 2.1 according to the each storage time of immediately, 3min, 24hour, 48hour and 1week, and then control and experimental groups were filled with light cured composite resin(Z-100). After 24 hours water storage at $37^{\circ}C$, all samples were subjected to a shear load to fracture at a cross head 1.0mm/min with Instron universal testing machine(No. 4467). Etched dentin surface storaged for each time of immediately, 3min, 24hour, 48hour and 1 week after eugenol application were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically with two-way ANOVA and Tukey's HSD. The results were as follows; 1. Shear bond strengths were higher in control groups than in the experimental groups. 2. As storage time was increased after eugenol application, the shear bond strengths were decreased in experimental groups. 3. In experimental I, II the shear bond strengths were the lowest in which storage time was 1 week after eugenol application. 4. As storage time was increased after eugenol application, etched dentin surfaces showed obstructed dentinal tubule.

  • PDF

The Development & Effect of an Tailored Falls Prevention Exercise for Older Adults (노인 낙상예방 맞춤운동의 개발 및 효과)

  • Gu, Mee-Ock;Jeon, Mi-Yang;Eun, Young
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.2
    • /
    • pp.341-352
    • /
    • 2006
  • Purpose: This study was conducted to develop & to determine the effect of an tailored falls prevention exercise for older adults. Method: Subjects consisted of 59 older adults (experimental group : 29, control group : 30) living at nursing homes. Experimental group participated in tailored falls prevention exercise for 16 weeks(3 times a week, 50 min every session). Data were collected before the exercise, 16 weeks & 24 weeks after the beginning of exercise. Results: 1) the experimental group significantly improved the muscle strength of hip extensor & flexor, knee extensor & flexor, ankle dorsiflexor, & plantar flexor compared to the control group. 2) the experimental group significantly decreased the mean time for 10 times chair stand. 3) the experimental group significantly increased the standing time on one leg and the number of heel raise for 30 seconds compared to the control group. In addition more older adults in the experimental group completed the tandem stance & semi-tandem stance for 10 seconds than the control group. 4) The experimental group significantly decreased the mean time of 6m walk and the fall frequency compared to the control group. Conclusions: This results suggest that tailored falls prevention exercise for older adults can improve muscle strength, static & dynamic balance and decrease the fall frequency of older adults.

Experimental Effects of Aucklandiae Radix and Cyperi Rhizoma Extract on Chronic Stress in Rats (목향과 향부자 추출물이 흰쥐의 만성 스트레스에 미치는 실험적 효과)

  • Choi, Chan Hun;Hong, Jun Yeong;Jeong, Hyun Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.36 no.2
    • /
    • pp.54-58
    • /
    • 2022
  • This study aimed to investigate the anti-stress function of Aucklandiae Radix (AR) and Cyperi Rhizoma (CR). The essential oils used in the experiment were extracted from AR and CR using Steam Distillation Extraction and Super critical CO2 extraction. To observe the effects of sample administration, we measured feed intake, leukocytes, red blood cells, hemoglobin, platelets, serum serotonin content, immobility time, climbing time, and swimming time in mice subjected to chronic restraint stress as behavioral changes. The average body weight of all experimental groups increased than the average body weight of the control group. The immobility and climbing times of experimental groups A and B administered with supercritical extraction samples were shorter than those of the other experimental groups and the control group, and the swimming time was longer. The serotonin content in the blood of all experimental groups decreased compared to the normal group, and the serotonin content of the control group was increased. The authors suggest that Korean herbal medicines AR and CR may be utilized as anti-stress flavoring agents based on the above results.