• 제목/요약/키워드: Experimental formula

검색결과 1,066건 처리시간 0.025초

점성감쇠형 면진장치에 관한 실험적 연구 (Experimental Study on Viscous Fluid Damper for Seismic Base Isolation System)

  • 정민기;박진일;권형오;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.590-595
    • /
    • 1998
  • This study was performed to obtain a numerical model for a viscous fluid damper from an experimental testing. The input signals for displacement were chosen as two type : a triangular and a sinusoidal forms. The performing test parameters were the area of the resistant plate and the oil film thickness of the viscous fluid and the temperature effect was neglected. The numerical model was established by assuming to behavior as an non-Newtonian fluid. The test results were summarized by the equation of F = 0.0308A(V/d)$^{0.51}$25/. Using the obtainal formula, the procedure to apply the viscous damper for a real structure design was introduced..

  • PDF

Axial loading tests and load capacity prediction of slender SHS stub columns strengthened with carbon fiber reinforced polymers

  • Park, Jai-Woo;Yoo, Jung-Han
    • Steel and Composite Structures
    • /
    • 제15권2호
    • /
    • pp.131-150
    • /
    • 2013
  • This paper presents the experimental results of axially loaded stub columns of slender steel hollow square section (SHS) strengthened with carbon fiber reinforced polymers (CFRP) sheets. 9 specimens were fabricated and the main parameters were: width-thickness ratio (b/t), the number of CFRP ply, and the CFRP sheet orientation. From the tests, it was observed that two sides would typically buckle outward and the other two sides would buckle inward. A maximum increase of 33% was achieved in axial-load capacity when 3 layers of CFRP were used to wrap HSS columns of b/t = 100 transversely. Also, stiffness and ductility index (DI) were compared between un-retrofitted specimens and retrofitted specimens. Finally, it was shown that the application of CFRP to slender sections delays local buckling and subsequently results in significant increases in elastic buckling stress. In the last section, a prediction formula of the ultimate strength developed using the experimental results is presented.

Experimental study on shear capacity of circular concrete filled steel tubes

  • Xiao, Congzhen;Cai, Shaohuai;Chen, Tao;Xu, Chunli
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.437-449
    • /
    • 2012
  • Concrete filled steel tube (CFST) structures have recently seen wide use in China, but studies of the shear problem of CFST are inadequate. This paper presents an experimental study on the shear capacity of circular concrete filled steel tube (CCFT) specimens with and without axial compression force. Shear capacity, ductility, and damage modes of CCFTs were investigated and compared. Test results revealed the following: 1) CCFTs with a small shear span ratio may fail in shear in a ductile manner; 2) Several factors including section size, material properties, shear span ratio, axial compression ratio, and confinement index affect the shear capacity of CCFTs. Based on test results and analysis, this paper proposes a design formula for the shear capacity of CCFTs.

도로변 가로수로 인한 전자파의 장애에 관한 연구 (A Study on Obstruction of Radio Waves by Trees on the Road)

  • 오일덕
    • 한국통신학회논문지
    • /
    • 제19권6호
    • /
    • pp.1149-1157
    • /
    • 1994
  • 위성을 이용한 이동통신시 도로 주변의 가로수가 신호감쇠의 주요 원인이 된다. 이러한 가로수로 인한 신호감쇠를 해석하기 위하여 가로수를 구형장애물들의 조합으로 모델화 시키고, 가로수 모델에 대한 신호세기의 변화를 Frensnel 및 Kirchhoff 회적이론을 근거로 유도하였다. 가로수 모델에 의한 신호감쇠를 송.수신 거리, 송.수신 단의 위치 및 고도각을 변화시켰을 때의 이론치를 수치해석적으로 계산하여 실험치와 비교하였다. 이론치와 실험치와를 비교한 결과 신호감쇠 경향이 일치함을 볼 수 있었다.

  • PDF

수중불분리콘크리트의 부착강도특성에 관한 연구 (A Study on the Bond Strength Properties of Antiwashout Underwater Concrete)

  • 김기동;윤재범;이상명;김명식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.153-159
    • /
    • 1999
  • The objective of this study was to investigate the bond strength properties of antiwashout underwater concrete. The fine aggregate(river sand, blended sand (river sand : sea sand = 1 : 1), condition of cast and cure(sea water, fresh water), and compressive strength of proportion(210kgf/$\textrm{cm}^2$ ~ 330kgf/$\textrm{cm}^2$) were chosen as the experimental parameters. The experimental results show that the underwater segregation resistance was increased, but flowability (slump flow) and air contents were decreased as the compressive strength of proportion increased. Bond strength of antiwashout underwater concrete was similar to plain concrete. From this study, rational analytic formula for the modulus of rupture and bond stress are to be from compressive strength of concrete.

  • PDF

수중 불분리성 콘크리트의 부착 강도 특성에 관한 연구 (Bond Strength Properties of Antiwashout Underwater Concrete)

  • 김명식;김기동;윤재범
    • 콘크리트학회논문집
    • /
    • 제12권1호
    • /
    • pp.89-99
    • /
    • 2000
  • The objective of this study is to investigate the bond strength properties of antiwashout underwater concrete. The arrangement of bars (vertical bar, horizontal upper bar, horizontal lower bar), condition of casting and curing (fresh water, sea water), type of fine aggregate (river sand, blended sand(river sand : sea sand = 1:1), and proportioning strength of concrete (210, 240, 270, 300, 330kgf/$\textrm{cm}^2$)are chosen as the experimental parameters. The test results(ultimate bond stress) are compared with bond and development provisions of the ACI Building Code(ACI 318-89) and proposed equations from previous research(which was proposed by Orangun et. al). The experimental results show that ultimate bond stress of antiwashout underwater concrete which arranged bar on the horizontal lower, used the blend sand, and was cast and cured in the fresh water are higher that other conditions. The ultimate bond stress were increased in proportion to {{{{( SQRT {fcu }) }}3 2. From this study, rational analytic formula for the ultimate bond stress are to be from compressive strength of concrete.

금형면 자동 다듬질 전문가 시스템 개발에 관한 연구-II-통합 연마 파라미터를 사용한 최적 가공 구현 및 전문가 시스템 구축- (Development of an Expert System for Optimizing Die and Mold Polishing-II)

  • 민헌식;이성환;안유민;조남규;한창수
    • 한국공작기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.45-51
    • /
    • 2002
  • To reduce the cost and increase reliability of die and mold products, automation of the finishing (polishing) process is essential. A major element of automation is a reliable database and a knowledge base for polishing status. This paper presents a polishing expert system which can determine optimal polishing sequences and conditions by using an empirical formula and an experimental database. The simplex method was used for the curve fittings of the experimental results. Also a graphical user interface, which visualizes the optimized results, was developed.

SNC815 기어의 피로강도에 미치는 열처리 효과에 관한 연구 (A Study on the Effect of Heat-treatment on the Fatigue Strength of SNC815 Spur Gears)

  • 류성기;남태현;이진이
    • 열처리공학회지
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 2000
  • This study deals with effects of heat-treatment on the fatigue strength of SNC815 spur gears. The test gears are heat-treated by two different treatments. After carburization, one group of the test gears is quenched directly, while the other group is fumace cooled, reheated then quenched. The fatigue test at a constant stress amplitude is performed by using an electrohydraulic servo-controlled pulsating tester. The S-N curves are obtained and illustrated. By comparing the estimated strength with the experimental results, the validity of the previous experimental formula, presented by the author for estimating the fatigue strength of carburized gears, was discussed on these tested gears.

  • PDF

점성 유체중에 자유낙하 하는 니들과 스프링의 거동에 관한 연구 (STUDY ON THE BEHAVIOR OF NEEDLES AND SPRINGS FALLING FREELY IN A VISCOUS FLUID)

  • 고담;서용권
    • 한국전산유체공학회지
    • /
    • 제19권2호
    • /
    • pp.30-39
    • /
    • 2014
  • We report in this paper the analysis of the motion of a needle and a spring in a viscous fluid under the influence of gravitational force. Lateral shift as well as vertical motion of a needle falling in a viscous fluid has been observed from a simple experiment. We also observed the combined rotation and translation of a falling spring. The trajectory and velocity of the falling needle and the spring were obtained by using an image processing technique. We also conducted numerical simulation for both problems. For the falling-needle problem, we employed a theory; but it turns out that significant correction is required for the solutions to match the numerical and experimental data. For the falling spring problem various theoretical formula were tested for their justification, but none of the existing theories can successfully predict the numerical and experimental results.

Nonlinear shear strength of pre-stressed concrete beams

  • Rahai, Alireza;Shokoohfar, A.
    • Structural Engineering and Mechanics
    • /
    • 제41권4호
    • /
    • pp.441-458
    • /
    • 2012
  • The shear strength is an important factor in the design of prestressed concrete beams. Therefore, researchers have utilized various methods to determine the shear strength of these elements for the design purposes. To evaluate some of the proposed theoretical methods, numerous models of post-tensioned beams with or without vertical prestressing are selected and analyzed using the finite element method and assuming nonlinear behavior for the materials. In this regard the validity of modeling is evaluated based on some tests results. In the second part of the study two beam specimens are built and tested and their load-deformation curve and cracking pattern are studied. The analytical results consist of compressive strut slope and mid span load deflection are compared with some experimental results, and the results of some codes' formulas. Finally comparing the results of nonlinear analysis with the experimental values, a new formula is proposed for determining strut slopes in prestressed concrete beams.