• Title/Summary/Keyword: Experimental Technique

Search Result 6,804, Processing Time 0.034 seconds

A Study on Temperature and Velocity Profiles of Natural Convection in a Square Enclosure (사각 밀폐공간내의 자연대류의 온도 및 속도 분포에 관한 연구)

  • Chang, Tae-Hyun;Lee, Jong-Boong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.391-397
    • /
    • 2004
  • This paper presented results of experimental and numerical work for natural convection in a square enclosure by using PIV technique. 2D PIV technique and liquid crystal are employed for velocity and temperature measurement in water. The numerical method used this work is a CFD corde, STAR-CD. The experimental work are compared with these of numerical results.

  • PDF

An Experimental Study on Swirling Flow in a Cylindrical Annuli by Using PIV Technique (원형 이중관 내에서 PIV 기법을 이용한 선회유동에 관한 실험적 연구)

  • 장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.666-674
    • /
    • 2003
  • An experimental investigation was performed to study the characteristics of turbulent swirling flow in an axisymmetric annuli. The swirl angle measurements were performed by flow visualization technique using smoke and dye liquid along the test tube. Using the Particle Image Velocimetry method, this study found the time-mean velocity distribution and turbulent intensity with swirl for Re = 20.000. 30.000, 50.000. and 70.000 along longitudinal sections and the results appear to be physically reasonable.

Experimental demonstration of holographic storage with discrete random phase-code multiplexing

  • Park, Youn-Sup;Shin, Dong-Hak;Jang, Ju-Seog
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.43-47
    • /
    • 2000
  • We studied experimentally a discrete random phase-code multiplexing technique for holographic data storage, which we believe can overcome some disadvantages of conventional random phase-code multiplexing adopting either a diffusion plate or a multimode fiber. Experimental demonstration is presented to show the potential usefulness and some characteristics of the discrete random phase-code multiplexing technique.

Identification of joint dynamics of mechanical structures using condensed F.E.M. model and experimental modal analysis (축약된 유한요소 모델과 실험적 모우드 해석을 이용한 기계구조물의 연결부 동특성 규명)

  • 최병욱;박병호;김광준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.426-439
    • /
    • 1988
  • Dynamic properties such as stiffness and damping of mechanical joints are essential for the accurate prediction of the dynamic behaviors of the system and subsequent improvement of the design. So far several techniques, analytical, experimental, or both have been developed. A technique using condensed F.E.M. model and Experimental Modal Analysis is presented to identify the joint structural parameters. First, modal parameters of structure are measured by certain complex frequency obtained from experiment to match with the order of the Experimental Modal Analysis model. Finally by equating the modal parameters obtained from experiment with those of the condensed system, the unknown joint structural parameters can be identified. A simulation study is conducted to investigate the accuracy of technique. The experiments are performed with ball bearings in a rotor bearing system.

A practical neuro-fuzzy model for estimating modulus of elasticity of concrete

  • Bedirhanoglu, Idris
    • Structural Engineering and Mechanics
    • /
    • v.51 no.2
    • /
    • pp.249-265
    • /
    • 2014
  • The mechanical characteristics of materials are very essential in structural analysis for the accuracy of structural calculations. The estimation modulus of elasticity of concrete ($E_c$), one of the most important mechanical characteristics, is a very complex area in terms of analytical models. Many attempts have been made to model the modulus of elasticity through the use of experimental data. In this study, the neuro-fuzzy (NF) technique was investigated in estimating modulus of elasticity of concrete and a new simple NF model by implementing a different NF system approach was proposed. A large experimental database was used during the development stage. Then, NF model results were compared with various experimental data and results from several models available in related research literature. Several statistic measuring parameters were used to evaluate the performance of the NF model comparing to other models. Consequently, it has been observed that NF technique can be successfully used in estimating modulus of elasticity of concrete. It was also discovered that NF model results correlated strongly with experimental data and indicated more reliable outcomes in comparison to the other models.

The Effect of Flexion-distraction Technique and Drop Technique on Pain and Sacral Angle of Patients with Lumbar Spine Herniated Intervertebral Disc (굴곡-신연기법과 낙차 교정법이 허리 척추사이원반 탈출증 환자의 시각적 상사 척도 및 엉치뼈 각에 미치는 영향)

  • Oh, Hyun-Ju;Choi, Seok-Joo;Lee, Kwan-Sub;Choi, Ji-Oun
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.3
    • /
    • pp.9-16
    • /
    • 2018
  • Background: In order to find out the effect of therapy methods through Flexion-distraction technique and drop technique on pain, sacral angle of patients with lumbar herniated intervertebral disc targeting patients with lumbar herniated intervertebral disc due to L5-S1. Method: This study was to present the directivity of the therapy method for lumbar herniated intervertebral disc by comparing and analyzing the spinal decompression therapy and provide an effective treatment method to patients with lumbar herniated intervertebral disc by identifying the therapeutic effect of Flexion-distraction technique and drop technique. The research period is March 1, 2018 to June 30, 2018 and subjects are the patients diagnosed as lumbar herniated intervertebral disc due to L5-S1 by their doctor through clinical findings and medical equipment such as X-ray, CT, MRI etc. Among patients who visited and hospitalized in S Orthopaedics located in Daegu and 30 female patients with sacral angle of more than $30^{\circ}$ were randomly classified into 15 people and we carried out treatment three times a week for 8 weeks for 15 people in the experimental group applying Flexion-distraction technique and drop technique and 15 people in the control group applying spinal decompression therapy to compare and analyze the changes in pain, sacral angle of patients with lumbar herniated intervertebral disc. Result: According to the results of this study, changes in the Visual Analogue Scale showed statistically significant differences in both the experimental group and control group(p<.05), while there was statistically significant difference in the comparison between groups before and after measurement of experimental group (p<.05). In the comparison within two groups of sacral angle, both groups showed statistically significant difference(p<.05) but there was no statistically significant difference in the comparison of scores between groups before and after measurement of each group(p>.05). Discussion: All those results the above proved that we need to confirm various benefits of the therapy with the flexion-distraction technique and drop technique, and the findings of the concerned study will possibly become useful information when doctors actually work on a therapy to treat patients with the lumbar herniated intervertebral disc.

Measurement of optical flow using horn and anandan techniques (Horn과 Anandan기법을 이용한 Optical flow 측정)

  • 송석진;남기곤;이장명
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.685-688
    • /
    • 1998
  • Measurement of optical flow is a core problem of matching through the analysis of image sequences. In this paper, horn's and anandan's techniques are analyzed to derive a better technique for matching. Experimental results show that Horn's technique has low accuracy in measuring the velocity of optical flow while anandan's technique has poor performaance for diverging images. Based upon this observation, a new technique for the measurement of optical flow is proposed.

  • PDF

Efficient Fault-Recovery Technique for CGRA-based Multi-Core Architecture

  • Kim, Yoonjin;Sohn, Seungyeon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.307-311
    • /
    • 2015
  • In this paper, we propose an efficient fault-recovery technique for CGRA (Coarse-Grained Reconfigurable Architecture) based multi-core architecture. The proposed technique is intra/inter-CGRA co-reconfiguration technique based on a ring-based sharing fabric (RSF) and it enables exploiting the inherent redundancy and reconfigurability of the multi-CGRA for fault-recovery. Experimental results show that the proposed approaches achieve up to 73% fault recoverability when compared with completely connected fabric (CCF).

Study on Measurement Errors due to Attenuation in Plannar Image technique (평면 이미지 기법에서 감쇠로 인한 측정 오차에 대한 연구)

  • Jeon, J.Y.;Kim, D.J.;Koh, H.S.;Yoon, Y.B.
    • Journal of ILASS-Korea
    • /
    • v.7 no.3
    • /
    • pp.24-30
    • /
    • 2002
  • In the analysis of the mass distribution and SMD(Sauter Mean Diameter), planar laser imaging technique is a convenient and useful one when compared to the mechanical pattemator or PDPA (Phase Doppler Particle Analyzer). But recorded signals at cameras and intensity of laser are distorted by attenuation. Using experimental datum and assumptions, we study measurement errors due to attenuation in plannar image technique.

  • PDF

Visualization of 2-Phase Flow at Heat Pipe using Neutron Imaging Technique (중성자 영상법을 이용한 Heat Pipe 내의 이상유동 가시화)

  • Kim, TaeJoo;Park, SuJi;Kim, JongYul;Doh, SeungWoo
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.15-21
    • /
    • 2016
  • The circular and flat heat pipe were experimentally investigated by using neutron imaging technique. This experimental study was performed at the DINGO of OPAL research reactor, Australia. The diameter of the circular heat pipe is 10 mm and the dimension of flat is $10(width){\times}3(thickness)mm2$, respectively. We used the distilled water as a coolant. The coolant distributions and 2-phase flow patterns were measured under heating conditions. Experimental results show that neutron imaging technique is a good tool to visualize the 2-phase flow and phenomena in the heat pipe. The coolant distributions and 2-phase flow patterns depend on installation posture of the heat pipe and volume ratio of the coolant. Finally, it was discussed to calculate the void fraction by neutron imaging technique.