• Title/Summary/Keyword: Experimental System

Search Result 22,518, Processing Time 0.04 seconds

Experimental Study on the Active Control of a Three-story Building using $\textrm{H}_2$method ($\textrm{H}_2$제어 기법을 적용한 3층 건물의 능동제어 실험)

  • Joo, Soek-Jun;Min, Kyung-Won;Lee, Sung-Kyung;Kim, Sung-Chon;Hong, Sung-Mok
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.225-232
    • /
    • 1999
  • For the study of the seismic-response control, it is necessary to use an experimental system with an earthquake simulator and control devices employing a hydraulic actuator system. However, such system is too expensive to prepare at the university laboratory. In this research, an economical experimental system is developed which has a small-sized earthquake simulator and an AMD using AC servo motors. An accurate mathematical model of the three-degree-of-freedom tests structure with an AMD is developed from the measurement of the input/output relationships of the structure. This paper demonstrates experimentally the efficacy of the frequency domain optimal control algorithm H$_2$in reducing the response of seismically excited building to verify the performance of the experimental system.

  • PDF

Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System (확산형 흡수식 냉동시스템의 기포펌프 성능실험)

  • 이재효;정의갑;윤재호;정의갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

Thermal-hydraulic behavior simulations of the reactor cavity cooling system (RCCS) experimental facility using Flownex

  • Marcos S. Sena;Yassin A. Hassan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3320-3325
    • /
    • 2023
  • The scaled water-cooled Reactor Cavity Cooling System (RCCS) experimental facility reproduces a passive safety feature to be implemented in Generation IV nuclear reactors. It keeps the reactor cavity and other internal structures in operational conditions by removing heat leakage from the reactor pressure vessel. The present work uses Flownex one-dimensional thermal-fluid code to model the facility and predict the experimental thermal-hydraulic behavior. Two representative steady-state cases defined by the bulk volumetric flow rate are simulated (Re = 2,409 and Re = 11,524). Results of the cavity outlet temperature, risers' temperature profile, and volumetric flow split in the cooling panel are also compared with the experimental data and RELAP system code simulations. The comparisons are in reasonable agreement with the previous studies, demonstrating the ability of Flownex to simulate the RCCS behavior. It is found that the low Re case of 2,409, temperature and flow split are evenly distributed across the risers. On the contrary, there's an asymmetry trend in both temperature and flow split distributions for the high Re case of 11,524.

MSBS-SPR Integrated System Allowing Wider Controllable Range for Effective Wind Tunnel Test

  • Sung, Yeol-Hun;Lee, Dong-Kyu;Han, Jong-Seob;Kim, Ho-Young;Han, Jae-Hung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.414-424
    • /
    • 2017
  • This paper introduces an experimental device which can measure accurate aerodynamic forces without support interference in wide experimental region for wind tunnel test of micro aerial vehicles (MAVs). A stereo pattern recognition (SPR) method was introduced to a magnetic suspension and balance system (MSBS), which can eliminate support interference by levitating the experimental model, to establish wider experimental region; thereby MSBS-SPR integrated system was developed. The SPR method is non-contact, highly accurate three-dimensional position measurement method providing wide measurement range. To evaluate the system performance, a series of performance evaluations including SPR system measurement accuracy and 6 degrees of freedom (DOFs) position/attitude control of the MAV model were conducted. This newly developed system could control the MAV model rapidly and accurately within almost 60mm for translational DOFs and 40deg for rotational DOFs inside of $300{\times}300mm$ test section. In addition, a static wind tunnel test was conducted to verify the aerodynamic force measurement capability. It turned out that this system could accurately measure the aerodynamic forces in low Reynolds number, even for the weak forces which were hard to measure using typical balance system, without making any mechanical contact with the MAV model.

Development of High-definition 3DTV Experimental System based on Dual Stream Method (듀얼스트림 방식에 기반한 고화질 3DTV 실험방송 시스템 개발)

  • Lee, Gwang-Soon;Jung, Kwang-Hee;Cheong, Won-Sik;Hur, Nam-Ho;Pyo, Kyung-Soo
    • Journal of Broadcast Engineering
    • /
    • v.16 no.3
    • /
    • pp.471-482
    • /
    • 2011
  • This paper introduces an development of high-definition(HD) 3DTV experimental broadcasting system and its experimental service that has been launched via three broadcasting network including terrestrial, cable and satellite in the late of 2010. This 3DTV experimental broadcasting service employs an innovative 3DTV broadcasting mechanism, called as dual stream method in which left and right images are encoded by using each video encoder and multiplexed using MPEG-2 system technology for guaranteeing backward-compatibility with legacy DTV. This paper specifically describes the developed experimental broadcasting system, concentrating on 3DTV re-multiplexer and 3DTV receiver. Finally, implementation and terrestrial 3DTV experimental broadcasting service results will be introduced from the point of objective and subjective evaluation.

A study on the Engine Mounting System of the 4WD Vehicle by Experimental Modal Analysis (실험적 모우드해석을 통한 4WD 자동차의 엔진마운트에 관한 연구)

  • 사종성;김광식
    • Journal of KSNVE
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 1991
  • In this study, the design concept of engine for 4WD vehicle is established by the experimental modal analysis. First, the relationships between frame and power transmission system are considered. Second, the effect of additional system (Front propeller shaft and Exhaust system) on the power transmission system is evaluated. As a result, it is desirable that of frame and power transmission system is shifted by the additional system. This is cause by the moment of inertia of the additional system, because the center of gravity location of the additional system is far from that of the power transmission system.

  • PDF

A Study on the design of operations system for managing the mobile communication network (이동통신망 관리용 운용시스템 설계에 관한 연구)

  • 하기종
    • Journal of the Korea Society for Simulation
    • /
    • v.6 no.2
    • /
    • pp.71-79
    • /
    • 1997
  • In this paper, operations system was designed for the centralization of data processing of various state information from the facilities of mobile communication network. And the system performance experimental system module was measured and analyzed from the designed experimental system module. The configuration of system design was presented with the centralized type to monite and control the facilities of mobile communication network in the central office. The communication process design of the internal system was implemented with the resource of message queue having a excellent transmission ability for processing of a great quantity of information in the inter-process communication among communication resources of UNIX system. The process with a server function from the internal communication processes was constructed with a single server or a double server according to the quantity of operations and implemented with the policy of the presented server. And then, we have measured performance elements in accordance with the change of input parameters from the designed experimental module : response time, waiting time, buffer length, the maximum quantity existing in message queue. And from these results, we have compared and analyzed the system state each server algorithm according to performance variations.

  • PDF

A Study on Regenerative Cooling System for Thrust Chamber Protection (연소실 보호를 위한 재생냉각 방식 연구)

  • Park, Hee-Ho;Kim, Jung-Hun;Choi, Young-Hwan;Kim, Yoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.78-85
    • /
    • 2005
  • The purpose of the study was to establish the design procedure and develop the program for designing regenerative cooling system. To obtain the design parameter necessary for the realization of regenerative cooling system, water-cooled regenerative cooling system was designed from suggested procedure. To compare experimental results with a present method of analytically predicting the heat transfer loads, $250kg_{f}$ experimental LRE with water-cooled regenerative cooling system was investigated. Based on the investigation, the good correction between the predicted and measured data was verified. Developed design program can be used to designing Kerosene- cooled regenerative cooling system. The basic experimental data and correlations obtained in this study for 250kgf experimental LRE with water-cooled regenerative cooling system can be directly applicable to the real LRE.

Experimental Study on the Control for a Randomly Disturbing Dynamic System (불규칙한 교란을 받는 동적 시스템의 제어에 관한 실험적 연구)

  • Lee, Jong-Bok;Cho, Yun-Hyun;Yang, In-Beom;Park, Sung-Man;Heo, Hoon
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1120-1125
    • /
    • 2007
  • Experimental study on the control of randomly disturbing system is conducted. External and internal disturbances are imposed to the system in combined manner. A vertical propeller system exposed horizontal weak turbulent air flow is chosen as an experimental model. The aim of the control system is to maintain the angular position of vertical propeller in parallel to air flow. Trajectory Tracking Stochastic Controller (TTSC) is designed to ensure system's stability while following system command. The Trajectory Tracking Stochastic Controller is composed of two controller, one is stochastic controller to suppress internal random noise and the other one is trajectory-tracking controller to follow the command having random noise. The proposed hybrid controller, TTSC, shows remarkable performance in pitch control of vertical propeller system in wind-tunnel test

  • PDF

Controller Auto-tuning Scheme using System Monitoring inFrequency Domain (주파수역에서 시스템 감시를 이용한 제어기 Auto-tuning기법)

  • 정유철;이건복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.136-139
    • /
    • 2000
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-Imp system; instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the conventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, experimental results of robot path-tracking control applied with various controllers is used, and then is analyzed with respect to a equivalent proportional controller. Experimental results and analytic results are well-matched.

  • PDF