• Title/Summary/Keyword: Expansion valve

Search Result 241, Processing Time 0.025 seconds

Usefulness of using Tissue Expander in Pediatric Patient (소아 환자에서 조직확장기 사용의 유용성)

  • Lee, Jun-Woo;Park, Chul-Gyoo;Park, Jong-Lim;Kim, Yong-Kyu
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.763-768
    • /
    • 2010
  • Purpose: Reconstruction of soft tissue defect using tissue expander can provide better flap which is more similar to surrounding tissue in color, skin texture and hair compared to other methods. Many pediatric patients need reconstruction of soft tissue defect because of giant congenital nevi, congenital or acquired malformations and burn scars. Reconstruction using tissue expander is adequate to minimize dysmorphism in these patients. We intended to assess outcomes of using tissue expander in pediatric patients by retrospective study. Methods: Total cases were 168 of pediatric patients who received soft tissue reconstruction using tissue expander by the same surgeon from February, 1982 to May, 2009. All patients who received soft tissue reconstruction were under 10 years old. Mean age was 4.3 years old, the youngest 13 months, the oldest 8 years. Eightynine cases were male and 79 cases were female. Most common cause was giant hairy nevi (67 cases, 39.9%), secondary cause was burn scar/scar contracture (61 cases, 36.3%). Trunk (38 cases, 22.6%) was most common anatomical location. Results: Soft tissue defects were successfully covered using tissue expander in 149 cases (88.7%) without major complications. There was infection on 8 cases (4.7%) and we treated by adequate antibiotics in these cases. There were tissue expander folding or valve displacement on 5 cases (3%). Conclusion: Usage of tissue expander is useful on pediatric patients because tissue expansion is rapid on children and there are less secondary contractures on operation site than full thickness skin graft. Because of psychological stress due to tissue expander, operation should be performed before school age.

Simulation on the performance of an automobile climate control system with Internal heat exchanger and TXV (내부열교환기와 TXV를 적용한 자동차용 공조시스템의 성능에 관한 수치적 연구)

  • Park, Cha-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.31-36
    • /
    • 2021
  • Recently, automobile air conditioning systems have applied an alternative refrigerant that can replace the high GWP refrigerant R134a due to the global warming problem. This study simulated the performance of an automobile climate control system with an internal heat exchanger and TXV. Refrigerant R1234yf was applied as the working fluid. Amesim, a commercial software program, was used to model the main components of the compressor, condenser, TXV, evaporator, and internal heat exchanger. As the outside temperature increased from 30℃ to 40℃, the cooling capacity of the system decreased by 3.1%, and the power consumption of the compressor increased by 17.1%. In addition, The performance characteristics of the refrigeration cycle were simulated by increasing the fin pitch of the condenser from 0.8 mm to 1.4 mm. When the fin pitch was larger than 1.0 mm, the condenser capacity decreased, and the system COP was lowered by 5.9%. When the fin pitch of the condenser was 0.8 mm, which was smaller than 1.0 mm, there was no significant change in the system performance. Hence, the optimal performance was observed at a fin pitch of 1.0 mm.

The Distribution Structure of the Internet Movie and Spatial Clustering of the Internet Movie Industry (인터넷 영화의 유통구조와 인터넷 영화산업의 공간적 집적화)

  • Lee, Hee-Yeon;Lee, Nan-Kyung
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.107-130
    • /
    • 2005
  • The purpose of this study were to examine the spatial distribution and locational characteristics of the Internet movie industry, to seize the value chains of the Internet movie industry and distribution structure of the internet movies, and to analyze the vertical-horizontal linkages of the Internet movie firms and their spatial clustering. Recently, the Internet movie industry has developed rapidly due to the development of techniques related to movie contents, the broadband Internet and a wide expansion of the high speed communication network and the increase of demands on movie contents. It has been found that 74$\%$ of the Internet movie industry was concentrated in Seoul. Especially this industry was quite agglomerated in several dongs of Gangnam-gu such as Yoeksam, Nonhyeon, Daechi and Samseung. The proximity of the same or similar business firms was the primary locational factors that influenced on the Internet movie industry, followed by other factors such as convenience of transportation, the reputation of the place, and proximity of technically supporting firms. The Internet movie industry had the valve chain composed of 'contents suppliers $\rightarrow$ contents distributors $\rightarrow$ service providers', However, there were also a complex network of the VOD copyright owner, VOD syndicator, and service providers in each category of the value chain. This research clearly revealed that the localized clustering has been formed with the movie contents providers, technically supporting firms, client firms, and cooperative-affiliated business firms related to the Internet movie industry, Additionally, a very intimate network has been established within the clustering, inducing the enlargement of the market and decrease of costs, the co-sharing of tacit knowledge, and the synergy effect.

  • PDF

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.

A Study on Adjustment of Operational Factor in A2O process (A2O공정 운전인자 조정에 대한 연구)

  • Yoo, Ho-Sik;Lee, Byonghi
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.3
    • /
    • pp.33-41
    • /
    • 2015
  • An alternative was investigated to maximize the treatment efficiency of wastewater treatment plant without large scale expansion. 79% of detention time was required for enough nitrogen control. As aeration time was extended, nitrification was processed, but opposite trend was seen in phosphorus. High concentration of $NO_3-N$ interrupted PAOs activity not to absorb phosphorus. An alternative was devised for selective use of anaerobic or anoxic zone. Trisection was suggested for alternative use of center room. The result was relatively successful. The concentration of phosphorus was reduced with reduction of nitrogen. Extended anaerobic condition seemed to stimulate denitrification. Valve connection of internal return from aeration tank will make it possible to use middle room alternatively. This method will be a good alternative for seasonal variation of water temperature.

Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System (항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구)

  • Kang, Hoon;Jung, Jongho;Jung, Minwoo;Chi, Yongnam;Yoo, Yongseon;Choi, Heeju;Byeon, Youngman;Kim, Youngjin;Oh, Kwangyoon;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.431-439
    • /
    • 2013
  • A cooling system is adopted to control the thermal load from the avionic equipments in an aircraft for stable operation. In this study, an avionic cooling system was designed and manufactured by adopting a vapor compression cycle with a closed-loop air-circulation system to investigate the operating characteristics of an alternative refrigerant. The performance characteristics of a cooling system adopting R236fa as an alternative refrigerant were experimentally determined by varying the refrigerant charging amount, expansion valve opening, and compressor rotation speed. The experimental results were analyzed and compared with those of a cooling system adopting R124 as a refrigerant. The possibility of the adoption of R236fa as an alternative refrigerant was verified, and design solutions were suggested to improve the system efficiency.

A Study on the Performance Characteristics of the Soft Ice Cream Machine Run by Refrigerant Mixture (R-290/R-32) (혼합냉매(R-290/R-32)를 사용하는 소프트 아이스크림 제조기의 성능 특성에 관한 연구)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.719-725
    • /
    • 2017
  • Frozen milk products are commonly made in small refrigeration machines. R-502 has long been used as a refrigerant for soft ice cream machines, but it is being replaced with R-404A due to the issue of ozone layer depletion. However, R-404A has high global warming potential, so it also needs to be replaced. In this study, a mixture of R-290 and R-32 was considered as a new refrigerant. An optimization and performance evaluation of the mixture were conducted for a freezer volume of 2.8 liters. The focus of the optimization was the appropriate refrigerant charge and the opening of the expansion valve. At the optimized conditions, ice cream was produced in 6 minutes and 24 seconds with the mixture, and the COP was 0.83. For R-404A, the ice cream production time was 6 minutes and 22 seconds, and the COP was 0.90. The results may be used for the design of food refrigeration machines and to optimize other refrigeration cycles.

Synthesis of Cathode Materials LiNi1-yCoyO2 from Various Starting Materials and their Electrochemical Properties

  • Song, Myoung-Youp;Rim, Ho;Bang, Eui-Yong;Kang, Seong-Gu;Chang, Soon-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.507-512
    • /
    • 2003
  • The LiN $i_{l-y}$ $Co_{y}$ $O_2$ samples were synthesized at 80$0^{\circ}C$ and 85$0^{\circ}C$, by the solid-state reaction method, from the various starting materials LiOH, L $i_2$C $O_3$, NiO, NiC $O_3$, $Co_3$ $O_4$, CoC $O_3$, and their electrochemical properties are investigated. The LiN $i_{l-y}$ $Co_{y}$ $O_2$ pre-pared from L $i_2$C $O_3$, NiO, and $Co_3$ $O_4$ exhibited the $\alpha$-NaFe $O_2$ structure of the rhombohedral system (space group; R3m). As the Co content increased, the lattice parameters a and c decreased. The reason is that the radius of Co ion is smaller than that of Ni ion. The increase in da shows that two-dimensional structure develops better as the Co content increases. The LiN $i_{0.7}$ $Co_{03}$. $O_2$[HOO(800,0.3)] synthesized at 80$0^{\circ}C$from LiOH, NiO, and $Co_3$ $O_4$ exhibited the largest first discharge capacity 162 mAh/g. The size of particles increases roughly as the valve of y increases. The samples with the larger particles have the larger first discharge capacities. The cycling performances of the samples with the first discharge capacity larger than 150 mAh/g were investigated. The LiN $i_{0.9}$ $Co_{0.1}$ $O_2$[COO(850,0.1)] synthesized at 85$0^{\circ}C$ from L $i_2$C $O_3$, NiO, and $Co_3$ $O_4$ showed an excellent cycling performance. The sample with the larger first discharge capacity will be under the more severe lattice destruction, due to the expansion and contraction of the lattice during intercalation and deintercalation, than the sample with the smaller first discharge capacity. As the first discharge capacity increases, the capacity fading rate thus increases.increases.s.s.s.

Quality Changes of Fresh-Cut Tumeric by Packaging Methods during Storage (포장방법에 따른 세절 생울금의 저장 중 품질 변화)

  • Kim, Dong-Hoo;Han, Jin-Soo;Woo, In-Bong;Jung, Jun-Jae;Park, Si-Woo;Heo, Kyung-Chel;Ha, Ju-hyeung;Yoon, Chan-Suk
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.3
    • /
    • pp.151-162
    • /
    • 2017
  • The purpose of this study was to investigate the quality change of fresh-cut tumeric (Curcuma Longa Linne) according to packaging method during storage time. The fresh-cut tumeric were packaged in three different methods : degassing valve packaging (DVP), $CO_2$ gas absorber packaging (CAP) and micro-perforated packaging (MPP). After the samples were packaged, they were stored for 15 days at 4 and $23^{\circ}C$ respectively. The following parameters were observed to indicate the quality changes of the samples: weight loss, CIE $L^*a^*b^*$ colour difference, variation of gas composition inside the package, curcumin contents and changes in hardness of fresh-cut tumeric. DVP did not effectively release $CO_2$ gas to the outside. MPP was suitable to release $CO_2$ gas. However, MPP showed very fast browning and erosion, because a large amount of oxygen was introduced through the perforated hole on the film. CAP was most effective packaging method to inhibit browning, to prevent expansion of the packaging by $CO_2$ gas and to minimize weight loss of fresh-cut tumeric.

Thermodynamic Analysis on Hybrid Turbo Expander - Heat Pump System for Natural Gas Pressure Regulation (히트펌프를 적용한 터보팽창기 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyoung Hoon;Han, Sangjo;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.13-20
    • /
    • 2014
  • In natural gas distribution system, gas pressure is regulated correspond to requirement using throttle valve which is releasing huge pressure energy as useless form. The waste pressure can be recovered by using turbo machinery devices such as a turbo expander. In this process, excessive temperature drop occurs due to Joule-Thompson effect during the expansion process. Installing natural gas boiler before or after the turbo expander prevents temperature drop. Fuel cell or gas engine hybrid system further improve the efficiency, but 1~2% of total transporting natural gas is used for operating the hybrid system. In this study, a heat pump system is proposed as a preheating device which can be operated without using transporting natural gas. Thermodynamic analysis on evaporating and condensing temperatures and refrigerants is conducted. Results show that R717 is proper refrigerant for the hybrid system with high COP and low turbine work within the defined operating conditions. In domestic usage in Korea, the heat pump system has more economic feasibility owing to natural gas being imported with a high price of LNG form.