• Title/Summary/Keyword: Expansion valve

Search Result 243, Processing Time 0.02 seconds

A System Operating Algorithm for the Effective Operation of a Multi-type Air-conditioning System (멀티형공조시스템의 효과적인 운전을 위한 시스템운전알고리즘)

  • Han Do-Young;Park Kwan-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.587-595
    • /
    • 2006
  • A system operating algorithm was developed for the effective operation of a multi-type air-conditioning system. The system operating algorithm includes control algorithms for a safety mode, an initial operating mode, a stabilization mode, a fault diagnosis mode, an efficiency mode, and a tracking mode. Various tests were performed to show the effectiveness of these algorithms. Tests showed good results for the operation of a multi-type air-conditioning system. Therefore, these algorithms developed for this study may be used for the effective control of a multi-type air-conditioning system.

Studies on Performance of CO2 Water Heater by Numerical Modeling (수치적 모델링을 통한 이산화탄소 급탕기의 특성 연구)

  • Park, Han Vit;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • Numerical modeling of $CO_2$ water heater was conducted prior to optimal design of medium and large sized $CO_2$ water heater, and the experimental test with small sized $CO_2$ water heater having heat capacity of 4 kW was completed to verify the present numerical model. The present model estimated the experimental data of COP(coefficient of performance), heating capacity, and the hot water outlet temperature within the range of 3% to 8% of mean deviation. As increase of EEV(electric expansion valve) opening area, decreasing of heating capacity and the hot water outlet temperature, and increasing of COP were found in both experimental and numerical investigation.

An Experimental Study on the Performance of Swash Plate Compressor with variations of Oil Charging Conditions (오일 충전량 변화에 따른 사판식 압축기 성능의 실험적 고찰)

  • Kim, Min-Jun;Park, Ik-Seo;Lee, Geon-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.704-709
    • /
    • 2003
  • The automobile air conditioning system generally consists of laminated type evaporator, swash plate type compressor, condenser, expansion valve and receiver drier. A swash plate type compressor has been used widely in automobile air conditioning system since 1955, because of wider operation range and better durability than other type compressors. In this study, the performance of an swash plate type compressor with variations of oil charging conditions has been investigated experimentally using the hot gas system. Further, the effects of varying compressor speed on the performance of the compressor has been discussed.

  • PDF

Simulation of a power cycle for a single-cylinder 4-stroke cycle spark ignition engine (단기통 4사이클 스파아크 점화기관 동력사이클의 시뮬레이션)

  • 조양수;유병철
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.47-61
    • /
    • 1983
  • In this paper the simulation of a thermodynamic power cycle for a 4-stroke, single-cylinder, spark-ignition engine was studied. In this simulation the cylinder volume was restricted to two zones, a burnt and an unburnt zone, and the convective heat transfer from cylinder contents to surroundings was considered. The chemical species in burnt gas considered was 12 species including H$_{2}$O, H$_{2}$, OH, H, N$_{2}$, NO, N, CO$_{2}$, CO, $O_{2}$, O and Ar. Using this model, computer program for compression, ignition and expansion processes was composed and pressure, temperature and composition of cylinder gas at each crank angle were computed. The composition of CO$_{2}$, CO, $O_{2}$ in the burnt gas when exhaust valve opens, the maximum temperature, the maximum flame speed and the combustion duration were also computed as a function of equivalence ratio. The relation between burnt mass fraction and burnt volume fraction was also computed.

  • PDF

Experimental Study of Characteristics on Double Heat Exchange Pipe Used Separation Type Air-Conditioner (분리형 에어컨용 2중 열교환 배관 특성에 관한 실험적 연구)

  • Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.31-37
    • /
    • 2006
  • In this study, the ability for the function of double pipe inserted liquid pipe with small diameter in the gas pipe with large diameter for the circulating of liquid of high temperature and high pressure and low temperature and low pressure at the same time is presented. And in this double pipe, liquid pipe of high temperature and pressure is used to connect condenser and expansion valve and gas pipe of low temperature is used to connect evaporator and compressor. Also, when liquid refrigerant of high temperature and gas refrigerant of low temperature is circulated by reversed flow in the double pipe. The contribution of liquid gas heat exchange pipe is studied by comparison of the effect of heat transfer by temperature difference when liquid pipe and gas pipe is installed separately.

  • PDF

An Experimental Study on Spark Timing Effect for Fast warmup of Catalyst to Cold Start Operation of an SI Engine (가솔린기관의 냉시동시 촉매 가열 촉진을 위한 점화시기 영향에 대한 실험적 연구)

  • Kwon, Y.W.;Ham, S.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.101-108
    • /
    • 2011
  • On cold start operation of an SI engine, a catalyst shows poor performance before it reaches activation temperature. Therefore, fast warmup of the catalyst is very crucial to reduce harmful emissions. In this study, an appropriate control strategy is investigated to increase exhaust gas temperature through changes of spark timing. Combustion stability is also considered at the same time. Exhaust gas temperature and pressure of combustion chamber are measured to investigate the effects of spark timings on cold start and idle performance. Experiments showed that retarded spark timing promotes the combustion at the end of expansion stroke and increases exhaust gas temperature during cold start.

The Control of Superheat and Capacity for a Variable Speed Refrigeration System Based on PI Control Logic

  • Hua, Li;Jeong, Seok-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.2
    • /
    • pp.54-60
    • /
    • 2007
  • In this paper, we suggest the high efficient control method based on general PI control law for a variable speed refrigeration system. In the variable speed refrigeration system, the capacity and the superheat are mainly controlled by an inverter and an electronic expansion valve, respectively, for saving energy and improving coefficient of performance. Thus, we proposed a decoupling model to eliminate the interfering loop between the capacity and superheat at first. Next, we designed PI controller to control the capacity and superheat independently and simultaneously. Finally, the control performance was investigated through some experiments. The experimental results showed that the proposed PI controller based on the decoupling model can obtain good control performance under the various control references and thermal load.

Test Results of Refrigerant R152a in a Mobile Air-Conditioning System

  • Shin, Jeong-Sub;Park, Won-Gu;Kim, Man-Hoe
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.2
    • /
    • pp.44-50
    • /
    • 2008
  • This study presents test results of a mobile air-conditioning system using a potential alternative refrigerant, R152a. A series of performance tests have been carried out and cycle characteristics such as cooling capacity, energy efficiency ratio, suction and discharge pressures, and temperatures are presented, compared to those for the baseline R134a system. Tests were conducted with evaporation temperature of $5^{\circ}C$, condensation temperature of $45^{\circ}C$, subcooling temperature of $5^{\circ}C$, superheating temperature of $5^{\circ}C$, and compressor speed of 500-1500 rpm. The performance of R152a system with readjustment of an expansion valve showed better than those of R134a. The effect of oil on the pressure drop in the evaporator was also addressed.

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.

Optimization of the Refrigerant Charge and the Expansion Valve Opening for the Soft Ice Cream Machine Using R-404A (R-404A를 사용하는 소프트 아이스크림 제조기의 냉매 충전량 및 팽창 밸브 개도 최적화)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.728-734
    • /
    • 2016
  • The improvements of living and lifestyle have led to the increased sales of frozen milk products, such as soft ice cream or slush. These frozen milk products are commonly made in small refrigeration machines. R-502, which has long been used as the refrigerant in soft ice cream machines, is being replaced with R-404A due to the ozone layer depletion issue. In this study, an optimization and performance evaluation were conducted on a soft ice cream machine with a freezer volume of 2.8 liters. The optimization focused on the appropriate refrigerant charge and expansion valve opening. Under the optimized conditions, ice cream was produced in 10 minutes and 5 seconds, and the COP was 0.57. The performance tests included ice cream sales with no interval, ice cream sales with 30 second intervals and under extreme outdoor conditions. The results showed that 20 sales were possible with no interval, and infinite sales could be made with 30 seconds intervals. Ice cream sales were also possible under summer or winter outdoor conditions. The present results may be used for the design of food refrigeration machines as well as to optimize other refrigeration cycles.