• Title/Summary/Keyword: Expanded uncertainty

Search Result 196, Processing Time 0.034 seconds

Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope and Uncertainty Evaluation (길이 표준 소급성을 갖는 원자간력 현미경을 이용한 2차원 격자 시편 측정과 불확도 평가)

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.68-75
    • /
    • 2007
  • The pitch and orthogonality of two-dimensional (2D) gratings have been measured by using a metrological atomic force microscope (MAFM) and measurement uncertainty has been analyzed. Gratings are typical standard artifacts for the calibration of precision microscopes. Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2D gratings, it is important to certify the pitch and orthogonality of 2D gratings accurately for nano-metrology using precision microscopes. In the measurement of 2D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme was required to overcome some limitations of current MAFM such as nonnegligible thermal drift and slow scan speed. Two kinds of 2D gratings, each with the nominal pitch of 300 nm and 1000 nm, were measured using line scans for the pitch measurement of each direction. The expanded uncertainties (k = 2) of measured pitch values were less than 0.2 nm and 0.4 nm for each specimen, and those of measured orthogonality were less than 0.09 degree and 0.05 degree respectively. The experimental results measured using the MAFM and optical diffractometer were coincident with each other within the expanded uncertainty of the MAFM. As a future work, we also proposed another scheme for the measurements of 2D gratings to increase the accuracy of calculated peak positions.

Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope with Uncertainty Evaluation

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.18-22
    • /
    • 2008
  • The pitch and orthogonality of two-dimensional (2-D) gratings were measured using a metrological atomic force microscope (MAFM), and the measurement uncertainty was analyzed. Gratings are typical standard devices for the calibration of precision microscopes, Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2-D gratings, it is important to certify the pitch and orthogonality of such gratings accurately for nanometrology. In the measurement of 2-D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme is required to overcome limitations such as thermal drift and slow scan speed. Two types of 2-D gratings with nominal pitches of 300 and 1000 nm were measured using line scans to determine the pitch measurement in each direction. The expanded uncertainties (k = 2) of the measured pitch values were less than 0.2 and 0.4 nm for each specimen, and the measured orthogonality values were less than $0.09^{\circ}$ and $0.05^{\circ}$, respectively. The experimental results measured using the MAFM and optical diffractometer agreed closely within the expanded uncertainty of the MAFM. We also propose an additional scheme for measuring 2-D gratings to increase the accuracy of calculated peak positions, which will be the subject of future study.

Uncertainty in the Course of Calibration of RF Multimeter using TVC (열전압변환기를 이용한 고주파전압계의 교정과 측정불확도)

  • 박정규;박석주;이환상;장경승;박명선
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.47-52
    • /
    • 2002
  • It was virtually declared that measurement science must abandon the error analysis of measurement when ISO had published "Guide to Expression of uncertainty in Measurement" International inclination of measurement field in order to guarantee the traceability and confidence of measurement results discards the error concept and instead analyzes the measurement uncertainty. In this paper we establish a mathematical model of measurement and analyze all uncertainty factors as possible as for yielding the measurement uncertainty in the course of the calibration of RF multimeter using Transfer Standard, Thermal Voltage Converter We produce the expanded uncertainty by analyzing cable effects, correlation of thermocoupler and DC meter, DC source, RF source, attenuator, reflection coefficients and DUT.s and DUT.

The Effect of Uncertainty in Sea Trial Measurement System on Speed-Power Performance

  • Seo, Dae-Won;Noh, Jackyou
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.3
    • /
    • pp.269-276
    • /
    • 2020
  • Sea trial tests are necessary to verify speed-power performance, and are an import contract between ship owners and shipyards. The International Organization for Standardization (ISO) published ISO 15016:2015, which specifies the correlation method between model and full-scale ships. The results of sea trials have been questioned because of the uncertainty of speed and power measurements, especially when sea conditions differ from ideal calm water conditions. In this paper, such uncertainties were investigated by utilizing the standard speed-power trial analysis procedure defined in ISO 15016:2015 through Monte Carlo simulations. It was found that the expanded uncertainty of the delivered power (PDid) at 95 % confidence interval (k = 2) was ±1.5 % under 75 % MCR conditions.

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

  • Lee, Jeong-Il;Lee, Cheol Min;Shim, In-Keun;Kim, Seong-Mi;Lee, Woo-Seok;Kim, Yoon-Shin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2394-2398
    • /
    • 2013
  • Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798, 10.1977, $98.3768{\mu}g/m^3$, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is $0.9435{\mu}g/m^3$ and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate ($1{\mu}L$ or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.

Calibration uncertainty of a capacitance diaphragm gauge (용량형진공계 교정 불확도)

  • 홍승수;신용현;정광화;임인태;우삼용;김정형;최상철
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.2
    • /
    • pp.173-181
    • /
    • 2001
  • We calibrated a capacitance diaphragm gauge(CDG) of 1,333 Pa range by using ultrasonic interferometer manometer (UIM) that was a national low vacuum standards system. And its uncertainties were evaluated according to International Organization for Standardization(ISO), they were named to A type uncertainty, B type uncertainty, combined standard uncertainty, and expanded uncertainty, We obtained that the combined standard uncertainties were $1.38 \times10^{-2}\; Pa\sim3.03 \times10^{-1} $Pa and the relative uncertainties(combined standard uncertainty/standard pressure) were $2.3 \times 10^{-4}\;Pa\sim7.9 X\times10^{-3} $Pa for this 1,333 Pa CDG.

  • PDF

Measurement Uncertainty calculation for improving test reliability of Agricultural tractor ROPS Test (농업용트랙터 ROPS 시험의 신뢰성 향상을 위한 측정불확도 추정)

  • Ryu Gap Lim;Young Sun Kang;Taek Jin Kim
    • Journal of Drive and Control
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2023
  • The agricultural tractor ROPS test method according to OECD code 4 is a test to assess whether the driver's safety area can be secured when a tractor overturns, and reliability should be ensured. In this study, a model formula and procedure for calculating measurement uncertainty expressing reliability in the field of agricultural machinery testing were established according to the ISO/IEC Guide 98-3:2008. The characteristics of the ROPS test device were assessed and repeated tests were performed, and the were used as factors to calculate the measurement uncertainty. As a result of repeated tests, the accuracy was higher than 1.9 % in all load directions; thus, they were, applied to calculate the type A standard uncertainty. The final expanded uncertainty was calculated within the range of less than ± 7.76 kN of force and ± 6.96 mm of deformation in all load directions.

Measurement Uncertainty of Arsenic Concentration in Ambient PM2.5 Determined by Instrumental Neutron Activation Analysis (기기 중성자방사화분석을 이용한 대기 중 PM2.5 내 Arsenic 농도 분석의 측정 불확도)

  • Lim, Jong-Myoung;Lee, Jin-Hong;Moon, Jong-Wha;Chung, Yong-Sam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1123-1131
    • /
    • 2008
  • In this study, measurement uncertainty of instrumental neutron activation analysis was evaluated for ambient As concentration in PM2.5. Expanded uncertainties of the measurements were calculated by applying both ISO-GUM approximation and Monte Carlo Simulation(MCS). The estimate of As concentration on a specific day by the Monte Carlo Simulation differed from that of ISO-GUM approximation by less than 4%. Relative expanded uncertainties of As concentrations from a total number of 60 PM2.5 samples were also estimated to be more or less than 10% with 95% confidence level using the Monte Carlo Simulation. Sensitivity test of the measurement uncertainties showed that $\gamma$-ray counting error(62.3%), efficiency(18.5%), air volume(12.3%), neutron flux(2.3%), and absolute gamma-intensity(1.8%) are major factors of uncertainty variations.

Calculation of Vertical Wind Profile Exponents and Its Uncertainty Evaluation - Jeju Island Cases (풍속고도분포지수 산정 및 불확도 평가 - 제주도 사례)

  • Kim, You-Mi;Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-yeol;Kim, Jin-Young;Kim, Chang Ki;Kim, Shin-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.11-20
    • /
    • 2016
  • For accurate wind resource assessment and wind turbine performance test, it is essential to secure wind data covering a rotor plane of wind turbine including a hub height. In general, we can depict wind speed profile by extrapolating or interpolating the wind speed data measured from a meteorological tower where multiple anemometers are mounted at different heights using a power-law of wind speed profile. The most important parameter of a power-law equation is a vertical wind profile exponent which represents local characteristics of terrain and land cover. In this study, we calculated diurnal vertical wind profile exponents of 8 locations in Jeju Island who possesses excellent wind resource according to the GUM (Guide to the Expression of Uncertainty in Measurement) to evaluate its uncertainty. Expanded uncertainty is calculated by combined standard uncertainty, which is the result of composing type A standard uncertainty with type B standard uncertainty. Although pooled standard deviation should be considered to derive type A uncertainty, we used the standard deviation of vertical wind profile exponent of each day avoiding the difficult of uncertainty evaluation of diurnal wind profile variation. It is anticipated that the evaluated uncertainties of diurnal vertical wind profile exponents at 8 locations in Jeju Island are to be registered as a national standard reference data and widely used in the relevant areas.