• Title/Summary/Keyword: Exit

Search Result 2,561, Processing Time 0.034 seconds

The effect of the flange attached to the inclined exit of tube on the noise radiation (관 경사출구에 부착된 플랜지가 소음방사에 미치는 영향)

  • Baek, Du-San;Yang, Yoon-Sang;Lee, Dong-Hoon;Lee, Yeong-gyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.134-137
    • /
    • 2014
  • The noise reduction performance of a passive facility is dependent on the its length or volume. In other words, this means that the larger the size of passive facility is, the better the noise reduction performance is. The sound directivity control has been proposed as an alternative for the noise reduction without a passive facility. The purpose of this study is to investigate the correlation between the flange attached to inclined exit of the tube and sound directivity when the sound radiates from the tube to the outside. As a result, the sound radiated from flanged tube had weak sound directivity in the wide angle. Also as the flange was bigger, the sound pressure level was lower in the behind the flange.

  • PDF

Numerical Study of Cyclone Dust Collector (싸이클론 집진기의 수치해석적 연구)

  • 전영남;엄태인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.43-53
    • /
    • 1996
  • Numerical simulation was performed for the 3-dimensional flow filed of gas and particle phase for cyclone dust collector. FVM(Finite Volume Method) was employed for gas phase. The flow was solved suing the k-.varepsilon. epsilon turbulence model. The particle exit at the bottom of the cone was treated as a solid wall in this model because the gas flow through the effective dust exit is usually insignificant. The major parameters considered in this study was vortex finder diameter, effective dust exit diameterm vortex finder length, inlet type for dimension performance. Particle trajectory calculations were made for three different, particle sizes of 1, 25 and 50 .mu.m. The results obtained from this study give some physical insight of dust particle collection mechanism together with the indication of the collection efficiency. The simulation results were in generally good agreement with empirical knowledge. The application of this kind of computer program looks promising as a potential tool for the design of cyclone and determination of optimum operating condition.

  • PDF

Measurement Techniques on Unsteady Flow at Impeller Exit (임펠러 출구에서의 비정상 유동 측정 기법)

  • Shin, You-Hwan;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.81-87
    • /
    • 1999
  • This study presents the measurement techniques on the periodic fluctuating flow such as the discharge flow of a centrifugal impeller in an unstable operating region. During rotating stall, the flow at the exit of a centrifugal compressor impeller fluctuates periodically with a lower frequency than that of the blade passing. To observe the blade-to-blade flow characteristics during the rotating stall, the phases of all the sampled data sets should be adjusted to those of the reference signals with two processes, in these processes, DPLEAT (Double Phase-Locked Ensemble Averaging Technique) can be used. From these measurements and data processing techniques, the characteristics illustrated a blade-to-blade flow with high frequency, but also a periodic rotating stall flow with a low frequency at the centrifugal impeller exit which was clearly observed.

  • PDF

A Study of the Seepage through Sand-Constructed Model Dams. (모래로 축조된 댐 모형의 침투에 관한 연구(I))

  • 신방웅
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.2
    • /
    • pp.64-82
    • /
    • 1980
  • The aim of this thesis, when water permeates dam, is to study the shape of seepage line and seepage quantity. As for the process, various sand model dams of same capacity were constructed in the water tank : they are a central, middle, inclined, up and down stream point of which is paralled, and filter-installed types. And the slope of seepage line and seepage quantity in these various models for experiment were measured, observed data were analyzed, and several formulas which already published were compared and examined. As for the shape of seepage line, the relation between upstream water level and exit: slope of seepage line, near the entrance and exit point, geometrically similar model, and the shape of seepage line filter-installed were examined. As regards to the seepage quantity, several formulas which already published and testing result values were compared and examined, and relation with the slope of seepage line, the seepage quantity, the slope of upstream point, and the upstream water level were mutually studied. Particulary, when horizontal filter was installed, propriety of the existing formulas for effective filter length w as examined, and the relative position of exit point in various. conditions was also studied.

  • PDF

Hybrid ARQ With Symbol Mapping Diversity and Turbo Demodulation based on LDPC Codes (심볼 맵핑 다이버시티와 터보 복조를 사용하는 LDPC 부호 기반의 Hybrid ARQ 기법)

  • Ahn, Seok-Ki;Yang, Kyeong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.9C
    • /
    • pp.841-847
    • /
    • 2009
  • In this paper we propose a high-performance Hybrid ARQ scheme employing Chase combining based on LDPC (Low-Density Parity-Check) codes. The proposed scheme uses symbol mapping diversity and turbo demodulation to improve decoding performance. We analyze the performance of the proposed scheme by EXIT (EXtrinsic Information Transfer) chart and compare its performance with several symbol mappings.

Study on the Horizontally Installed Emergency Exit in Apartment Houses (아파트 하향식 피난구에 대한 고찰)

  • Yeo, In-Hwan;Min, Byung-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05b
    • /
    • pp.91-93
    • /
    • 2010
  • Recently, the regulation about HEE(horizontally installed emergency exit) established at upper 4story in apartment houses was introduced by revising enforcement degree of Building Act. HEE is a facility for egress to lower story through floor breach and ladder system so that it gives a useful evaquation way directly to an individual household in apartment when they failed to evacuate through the entrance door. HEE may offer an opportunity to optain two way egress path ways instead of evacuation space at balcony and through path way to adjacent household in building and that might be an big strengh. but it needs to guarantee for against the crime, getting detailed reviews for being security and supplementation of fire test methods.

  • PDF

Dynamic Simulation of a Dedicated Outdoor Air-conditioning System (외기 전용 공조기의 동특성 시뮬레이션)

  • Kim, Jung-Min;Kim, Young-Il;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

A Contact-free type door control System with Proximity Switch (근접센서를 이용한 비접촉 방식의 출입문 감지제어 시스템)

  • Kim sung soo;Lee gi soo;Ahn Cheong Mo;Yoo Ju Hyon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1063-1070
    • /
    • 2005
  • Number of subway train units that Seoul Metropolitan Subway Corporation as at September 2005 is 1.944 on 4 routes from 60 units at the time of commencement of operation, having grown exponentially. Along with increase in the number of passengers the role of subway as safer and expedient means of transportation is now being required. Furthermore, the Corporation has been researching on means of improving the safety and reliability of subway entry/exit doors which has become an essential task and directly effect the safety of the passengers. In this Study, has developed sensory control system for the entry/exit door of the subway train using non-contact proximity sensor as a part of review of and measures against various issues of entry/exit door of the subway trains currently under operation. In addition, this sensor system was verified through test production and tests. If this technology becomes commercialized and practically utilized in the future, it would be able to make definite contribution to the safer transportation of passengers.

  • PDF

Improving Iterative Detection and Decoding Based on SC-MMSE with EXIT Analysis (EXIT 차트분석을 이용한 SC-MMSE기반 반복수신기의 성능 증대)

  • Nam, Jun-Yeong;Kim, Seong-Rak;Jeong, Hyeon-Gyu
    • Information and Communications Magazine
    • /
    • v.24 no.12
    • /
    • pp.14-21
    • /
    • 2007
  • This paper aims to improve the design of iterative detection and decoding(IDD) based on the soft interference cancellation with minimum mean squared error(SC-MMSE) detector, which shows low performance compared to the maximum a posteriori(MAP) detector. By means of extrinsic information transfer(EXIT) chart analysis, such low performance may be attributed to that the "pure"(original) turbo principle is not always best for IDD. Thus, we propose a new IDD architecture based on the SC-MMSE detector which uses new a priori information. Simulation results show that the performance of the proposed IDD is very close to that of IDD based on the MAP detector.

Performance Analysis of Fin-tube Evaporator for Carbon Dioxide (이산화탄소용 핀-관 증발기의 성능해석)

  • 이민규;김영일;장영수;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.645-651
    • /
    • 2004
  • Fin-tube evaporator for carbon dioxide has been investigated both by experiment and simulation. Inside refrigerant heat transfer and outside heat and mass transfer of a wet surface heat exchanger were modeled using appropriate correlations. The results estimated by the calculation were in good agreement with the experimental results. The simulation errors were less than 7.9% for estimating capacity, 0.6$^{\circ}C$ for air exit temperature, 1.2% for air exit humidity and 17% for $CO_2$ exit pressure. The simulation program was used to study the effect of air flow direction, number of rows and refrigerant circuits. For a 2-row evaporator, parallel flow showed better performance for low air velocity but for high air velocity, counter-flow was better. Refrigerant circuits, however, showed insignificant effect on the performance.