Study on Disaster Prevention in Case of Fire at Subway Platform with Platform Screen Door

  • Rie, Dong-Ho;Yoon, Sung-Wook;Ko, Jae-Woong;Lee, Keun-Oh
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.36-42
    • /
    • 2005
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating an environment necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Total of six different cases are made and performances are compared each other to find optimal vents operation to ensure safer environment for evacuation at the platform area considering the installation of platform screen door.

밸브벽면의 제트부착효과에 기인한 질량유량 감소에 관한 연구 (A Study on the Reduction of Mass Flow Rate due to Jet-Valve wall Attachment Effect)

  • 이준서
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 추계학술대회 논문집
    • /
    • pp.235-241
    • /
    • 1998
  • Flow characteristics of a compressible gas flow through a rotating disc-type rotary valve are investigated experimentally under various conditions. It is known that the mass flow rate through poppet valves of 4-stroke cycle engines and through piston valves of 2-stroke cycle engines decrease with increase in engine speed. Rotary valve is one means by which air maybe made to flow intermittently through a pipe. In this paper a exhaust system simulator of engine was used to experimentally analyzer the decrease inflow rate at high rotation speeds and to determine what variables, other than rotational speed, give rise to the observed behaviour. These variables have been included in an empirical equation which is representative of the measured flow characteristics.

  • PDF

디스플레이공정 진공시스템 밸브응용에 따른 진공특성 전산모사 (Simulation of Vacuum Characteristics by Applications of Vacuum Valves in Display Processing)

  • 김형택
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.77-83
    • /
    • 2012
  • 진공 시스템의 성능에 대한 밸브 컨덕턴스의 영향은 진공시스템의 설계 최적화를 위해 전산모사 되었다. 본 연구에서는, 전산모사기인 VacSimMulti에 의한 모델링기구가 제시되었다. 진공 시스템의 설계는 진공 장비의 다양한 산업적 구현을 위해 특정한 프로세스 조건을 충족해야 한다. 진공 밸브의 구조, 길이, 직경 등은 컨덕턴스 영향의 전산모사 변수로서 모델링 되었으며, 직렬 진공 시스템의 배기 밸브 또한, 다양한 크기와 구조로 모델링하여 전산모사되었다. 밸브 직경의 변화는 도관의 길이의 변화보다 진공특성에 있어 더 유의미한 효과를 보여주었으며 슬릿형의 밸브도관 시스템은 모델링된 밸브구조 중 가장 뛰어난 진공특성을 가지는 것으로 관찰 되었다.

커먼레일 엔진에서 노킹 진단 알고리즘 구현 및 OBD-II 진단기 S/W 설계 방안 (Implement of Knocking diagnostic algorithm and design of OBD-II Diagnostic system S/W on common-rail engine)

  • 김화선;장성진;남재현;장종욱
    • 한국정보통신학회논문지
    • /
    • 제16권11호
    • /
    • pp.2446-2452
    • /
    • 2012
  • 국내외의 배출가스 규제 강화에 부합하기위하여, 사용자 의도에 따른 연료 분사시기와 분사량 조절이 가능한 커먼레일 ECU를 제어할 수 있는 알고리즘 개발의 필요에 따라서 본 논문에서는 커먼레일 엔진 전용 ECU에 적용할 수 있는 노킹 판별 및 엔진 밸런스 보정이 가능한 노킹 진단 알고리즘을 구현하여 시뮬레이터로 개발하였다. 또한 운전자가 직접 차량을 진단하는 운전자 중심의 진단 서비스를 제공하고자 시뮬레이터의 결과를 OBD-II 표준에 의거하는 차량 위주의 진단기로 개발하고자 한다. 이를 위해 자동차 고장진단 신호 및 센서 출력 신호를 송수신하는 유선 시스템과 무선 시스템인 블루투스 모듈을 이용하여 실시간 통신이 제공될 수 있는 OBD-II 진단기 S/W 설계방안을 제안함으로써 차량의 연비향상 및 유해가스 저감을 통한 엔진의 효율성 향상을 실현하도록 한다.

특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구 (Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System)

  • 이수경;홍대화
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.85-90
    • /
    • 2011
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템에서 화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 형성되는 방연풍속의 특성을 FDS를 이용하여 해석하였고, 해석 결과를 분산분석으로 기류의 특성에 따른 측정 방안을 분석하고자 한다. 부속실과 같은 구획공간의 설계 조건에서 급기댐퍼에서 토출되는 보충량은 심한 와류를 형성하고 형성된 와류의 범위 안에 출입문이 존재할 경우 비정상적인 기체의 유동이 출입문지점에 발생한다는 것을 선행연구를 통하여 확인할 수 있었다. 국가화재안전기준 NFSC 501A에서 방연풍속을 측정할 때에는 출입문의 개방에 따른 개구부를 대칭적으로 균등 분할하는 10 이상의 지점에서 측정하는 풍속의 평균치로 할 것으로 정하고 있으나 이러한 조건에서는 출입구 상부 지점에 기류의 유입 현상을 파악하기 어렵고 풍속의 편차가 심하기 때문에 측정점을 공기조화설비의 시험조정 평가 기술기준에서 제시하는 64점 이상으로 세분화하여 측정하여야 할 것이다.

겨울철 서울시 일부 실내스포츠시설에서 금연정책 실시 전후 PM2.5 농도 비교 (Comparison of PM2.5 Concentrations before and after Smoke-free Policy in Some Indoor Sports Facilities in Seoul)

  • 김윤지;이기영;김승원
    • 한국환경보건학회지
    • /
    • 제44권3호
    • /
    • pp.267-274
    • /
    • 2018
  • Objectives: This study examined the impact of a smoke-free policy on indoor air quality at indoor recreation facilities by assessing $PM_{2.5}$ concentrations before and after the implementation of the new policy. Methods: Using real-time monitors, $PM_{2.5}$ concentrations were measured in 50 billiard rooms and 50 golf simulator rooms in Seoul, Korea. The characteristics of the indoor recreation facilities, smoking status, and atmospheric conditions were recorded at the same time.After the enforcement of a smoke-free policy, $PM_{2.5}$ concentrations, installation of smoking room, and smoking status were examined when the facilities were revisited. Results: Almost a half of the billiard rooms and over 80% of golf simulator rooms were located underground. Seventy percent of the billiard rooms and one hundred percent of the golf simulator rooms were equipped with a local exhaust ventilation system. After the implementation of the smoke-free policy, 46% of the billiard rooms and 20% of the golf simulator rooms newly installed a smoking room. In the billiard rooms with a newly-installed smoking room, the $PM_{2.5}$ concentrations decreased from 97.9 to $45.6{\mu}g/m^3$ after the implementation of the smoke-free policy. The same change of 29.0 to $ 26.3{\mu}g/m^3$ was not statistically significant in golf simulator rooms. Indoor $PM_{2.5}$ concentrations were correlated with outdoor $PM_{2.5}$ concentrations, number of smokers, and number of people in the room. Conclusions: The smoke-free policy for indoor recreation facilities was not effective at making the indoor spaces free from second hand smoke. Although a few billiard rooms installed a smoking room, indoor $PM_{2.5}$ concentrations were still higher than those of outdoor $PM_{2.5}$ or atmospheric $PM_{2.5}$. Stricter enforcement of the smoke-free policy should be achieved to prevent secondhand smoke exposure.

페라이트계 스테인리스강 재현 용접 열 영향부의 석출거동 및 열피로 특성에 미치는 구속응력의 영향 (Effect of Restraint Stress on the Precipitation Behavior and Thermal Fatigue Properties of Simulated Weld Heat Affected Zone in Ferritic Stainless Steel)

  • 한규태;강용준;이상철;홍승갑;정홍철;이창희
    • Journal of Welding and Joining
    • /
    • 제33권6호
    • /
    • pp.6-12
    • /
    • 2015
  • Thermal fatigue life of the automobile exhaust manifold is directly affected by the restraint force according to the structure of exhaust system and bead shape of the welded joints. In the present study, the microstructural changes and precipitation behavior during thermal fatigue cycle of the 18wt% Cr ferritic stainless steel weld heat affected zone (HAZ) considering restraint stress were investigated. The simulation of weld HAZ and thermal fatigue test were carried out using a metal thermal cycle simulator under complete constraint force in the static jig. The change of the restraint stress on the weld HAZ was simulated by changing the shape of notch in the specimen considering the stress concentration factor. Thermal fatigue properties of the weld HAZ were deteriorated during cyclic heating and cooling in the temperature range of $200^{\circ}C$ to $900^{\circ}C$ due to the decrease of Nb content in solid solution and coarsening of MX type precipitates, laves phase, $M_6C$ with coarsening of grain and softening of the matrix. As the restraint stress on the specimen increased, the thermal fatigue life was decreased by dynamic precipitation and rapid coarsening of the precipitates.

물/부동액-기반Al2O3나노유체를 이용한 차량용 냉각시스템 성능 향상에 관한 실험적 연구 (Experimental Investigation on the Thermal Performance Enhancement of Cooling System for Vehicles using Water/Coolant-Based Al2O3 Nanofluids)

  • 박용준;김현진;이승현;최태종;강예준;장석필
    • 한국분무공학회지
    • /
    • 제20권2호
    • /
    • pp.65-69
    • /
    • 2015
  • In this study, the thermal performance of vehicle's cooling system is experimentally investigated using the water/coolant-based $Al_2O_3$ nanofluids as working fluids. For the purpose, the water/coolant-based $Al_2O_3$ nanofluids are prepared by twostep method with gum arabic. In order to obtain the well-suspended nanofluids, the agglomerated $Al_2O_3$ nanoparticles are precipitated using centrifugal force and the experiments are performed with supernatant of them. The thermal conductivity is measured by transient hot wire method and the thermal conductivity of nanofluids is enhanced up to 4.8% as compared to that of base fluids. Moreover, the cooling performance of water/coolant-based $Al_2O_3$ nanofluids is evaluated using vehicle's engine simulator under the constant RPM condition. The results show that the cooling performance of automobile engine increases up to 5.9% using prepared nanofluids. To investigate the effect of nanofluids on exhaust gas, the $NO_x$ emission is measured during the operation with respect to time and 10.3% of $NO_x$ emission is decreased. The experimental results imply that the water/coolant-based $Al_2O_3$ nanofluids might be used as a next-generation vehicles' coolant

도로터널 환기시뮬레이션 모델 현장적용 연구 (On-site Application of a Vehicle Tunnel Ventilation Simulator)

  • 이창우;김효규
    • 터널과지하공간
    • /
    • 제11권4호
    • /
    • pp.319-327
    • /
    • 2001
  • 장대도로터널 환기시스템의 최적 설계 및 운영은 새로운 설계도구의 개발을 요구하며 최근 환기 관련 변수들의 동적인 관계를 정량적으로 분석할 수 있는 도구로써 널리 이용되고 있다. 본 연구는 도로터널 환기시뮬레이션 모델인 NETVEN의 현장 검증연구를 국내 도로터널을 대상으로 수행함을 목적으로 하였다. 환기방식 및 차량통행방식이 다른 4개 터널을 대상으로 시뮬레이션 및 현장 측정연구를 수행하였으며 시뮬레이션 모델의 적용 결과와 측정 결과의 차이는 다음 4가지 요인에 기인한 것으로 분석된다. (1)실제 터널내 기류는 정상류 유동을 가정하는 시뮬레이션 모델과는 달리 천이-지연계의 특성을 가지고 있다. (2) 시뮬레이션 모델은 정상상태를 가정하나 측정값은 순간값을 대상으로 하므로 분산이 상대적으로 크게 나타난다. 환기력 관련변수들은 거의 정상상태가 아니며 교통 및 기상관련 변수들은 특히 순간적인 변화가 심한 편이다. (3) CO 농도의 경우에 출구부근에서의 차이가 상대적으로 크게 나타나는 현상이 뚜렷하며 특히 농도가 상대적으로 클수록 차이가 크다. 이는 난류확산에 의한 농도 저하가 원인으로 보인다. 난류확산 가능성은 최대 농도지점이 출구점이 아닌 약간 안쪽 지점에서 나타나는 현상에서도 나타나고 있다. (4) 교통량이 많을 경우 환기속도 오차가 크게 나타나므로 차량의 배기특성뿐만 아니라 공기역학적 특성에 대한 지속적인 연구가 필요하다.

  • PDF

SOEC에 과열기의 고온 스팀을 공급하는 Interface의 열전달에 관한 전산해석 (A CFD Analysis on Heat Transfer of High Temperature Steam through Interface with Superheater and SOEC for Hydrogen Production)

  • 변현승;한단비;박성룡;조종표;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.169-176
    • /
    • 2020
  • There is a growing interest in hydrogen energy utilization since an alternative energy development has been demanded due to the depletion of fossil fuels. Hydrogen is produced by the reforming reaction of natural gas and biogas, and the electrolysis of water. An solid oxide electrolyte cell (SOEC) is reversible system that generates hydrogen by electrolyzing the superheated steam or producing the electricity from a fuel cell by hydrogen. If the water can be converted into steam by waste heat from other processes it is more efficient for high-temperature electrolysis to convert steam directly. The reasons are based upon the more favorable thermodynamic and electrochemical kinetic conditions for the reaction. In the present study, steam at over 180℃ and 3.4 bars generated from a boiler were converted into superheated steam at over 700℃ and 3 bars using a cylindrical steam superheater as well as the waste heat of the exhaust gas at 900℃ from a solid refuse fuel combustor. Superheated steam at over 700℃ was then supplied to a high-temperature SOEC to increase the hydrogen production efficiency of water electrolysis. Computational fluid dynamics (CFD) analysis was conducted on the effects of the number of 90° elbow connector for piping, insulation types and insulation layers of pipe on the exit temperature using a commercial Fluent simulator. For two pre-heater injection method of steam inlet and ceramic wool insulation of 100 mm thickness, the highest inlet temperature of SOEC was 744℃ at 5.9 bar.