• Title/Summary/Keyword: Exercise monitoring System

Search Result 63, Processing Time 0.039 seconds

Comparison of the Metabolic Costs of Gardening and Common Physical Activities in Children

  • Park, Sin-Ae;Lee, A-Young;Lee, Kwan-Suk;Son, Ki-Cheol
    • Horticultural Science & Technology
    • /
    • v.32 no.1
    • /
    • pp.123-128
    • /
    • 2014
  • This study investigated the exercise intensity and energy expenditure involved in two gardening activities (planting transplants and sowing seeds in a garden plot) and four common physical activities (running, skipping rope, walking, and throwing a ball) in children. Eighteen children aged 11 to 13 years (mean age, $12.3{\pm}0.7$ years) participated in this study. The children made two visits to a high tunnel in Cheongju, Chungbuk, South Korea and performed randomly selected activities. Each activity was performed for 10 min, with a 5-min rest period between activities. The children wore a Cosmed $K4b^2$ (Cosmed $K4b^2$; Cosmed, Rome, Italy), which is a portable calorimetric monitoring system, to measure indicators of metabolic cost such as oxygen uptake and energy expenditure. The children's heart rates during the activities were measured by radiotelemetry (Polar T 31; FitMed, Kempele, Finland). We found that the two gardening and four physical activities performed by the 11-13 years old children in this study were moderate-to high-intensity physical activities [i.e.,$5.4{\pm}0.7$ to $9.1{\pm}1.4$ metabolic equivalents (METs)]. Running ($9.1{\pm}1.4$ METs) and skipping rope ($8.8{\pm}1.1$ METs) were high-intensity physical activities, whereas walking ($6.1{\pm}0.9$ METs), planting transplants ($5.8{\pm}1.1$ METs), throwing a ball ($5.6{\pm}1.1$ METs), and sowing seeds ($5.4{\pm}0.7$ METs) were moderate intensity physical activities. Running and skipping rope were significantly more intense than the other activities (P < 0.0001). The gardening tasks such as planting transplants and sowing seeds in a garden plot showed similar exercise intensities and energy costs as walking and throwing a ball. This study indicates that gardening can be used as a physical activity intervention to provide health benefits similar to more common physical activities such as walking and running.

The Present State of Marine Oil Spills and the Enhancement Plans of National Oil Spill Response Capability in Vietnam - Through the Comparison of Statistics and OSR System between Vietnam and Republic of Korea - (베트남의 해양기름유출 현황과 국가대응역량 증강 방안 - 통계자료와 유출유 방제시스템에 대한 베트남과 한국 간의 비교를 통하여 -)

  • Phan, Van Hung;Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.690-698
    • /
    • 2017
  • Vietnam is a marine nation with more than 3,444 km of shorelines, thousands of islands, and 2,360 rivers and canals of over 42,000 km long. As the frequency and the volume of oil transportation by ships increase, the possibility of oil spill incidents becomes higher than ever. Fuel oil and cargo oil spills at sea have widespread impact and long-term consequences on marine ecosystems, coastal resources and human health as well as socio-economy. This study is to show not only the present state of marine oil spills in Vietnam such as the number and the volume of oil spills for two decades, and an overall about Vietnamese national response system like national framework for Oil Spill Response (OSR), etc. but also to present the recommendations for enhancing national capability in response to oil spill incidents in Vietnam, especially, with a comparison of national OSR systems between Vietnam and South Korea. As the result, the number and the volume of marine oil spills in Vietnam showed an upward trend as opposed to a downward trend in South Korea. This means that Vietnam has the possibility of oil spills in coastal waters. Therefore, three main recommendations for the enhancement of national OSR capability in Vietnam are proposed as follows: (1) the development of alternative plan for reenforcing national OSR system involving legal system for preparedness and response to oil spill pollution such as the acceptance and implementation of OPRC Convention as well as the establishment of national fund compensating for the damage and loss caused by oil pollution; (2) the enhancement of a consistent reporting, alerting and monitoring system; and (3) the development of training and exercise programs with standard contents of educational courses.

CNN-LSTM-based Upper Extremity Rehabilitation Exercise Real-time Monitoring System (CNN-LSTM 기반의 상지 재활운동 실시간 모니터링 시스템)

  • Jae-Jung Kim;Jung-Hyun Kim;Sol Lee;Ji-Yun Seo;Do-Un Jeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.3
    • /
    • pp.134-139
    • /
    • 2023
  • Rehabilitators perform outpatient treatment and daily rehabilitation exercises to recover physical function with the aim of quickly returning to society after surgical treatment. Unlike performing exercises in a hospital with the help of a professional therapist, there are many difficulties in performing rehabilitation exercises by the patient on a daily basis. In this paper, we propose a CNN-LSTM-based upper limb rehabilitation real-time monitoring system so that patients can perform rehabilitation efficiently and with correct posture on a daily basis. The proposed system measures biological signals through shoulder-mounted hardware equipped with EMG and IMU, performs preprocessing and normalization for learning, and uses them as a learning dataset. The implemented model consists of three polling layers of three synthetic stacks for feature detection and two LSTM layers for classification, and we were able to confirm a learning result of 97.44% on the validation data. After that, we conducted a comparative evaluation with the Teachable machine, and as a result of the comparative evaluation, we confirmed that the model was implemented at 93.6% and the Teachable machine at 94.4%, and both models showed similar classification performance.

Development of Signal Detection Methods for ECG (Electrocardiogram) based u-Healthcare Systems (심전도기반 u-Healthcare 시스템을 위한 파형추출 방법)

  • Min, Chul-Hong;Kim, Tae-Seon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.6
    • /
    • pp.18-26
    • /
    • 2009
  • In this paper, we proposed multipurpose signal detection methods for ECG (electrocardiogram) based u-healthcare systems. For ECG based u-healthcare system, QRS signal extraction for cardiovascular disease diagnosis is essential. Also, for security and convenience reasons, it is desirable if u-healthcare system support biometric identification directly from user's bio-signal such as ECG for this case. For this, from Lead II signal, we developed QRS signal detection method and also, we developed signal extraction method for biometric identification using Lead II signal which is relatively robust from signal alteration by aging and diseases. For QRS signal detection capability from Lead II signal, ECG signals from MIT-BIH database are used and it showed 99.36% of accuracy and 99.68% of sensitivity. Also, to show the performance of signal extraction capability for biometric diagnosis purpose, Lead III signals are measured after drinking, smoking, or exercise to consider various monitoring conditions and it showed 99.92% of accuracy and 99.97% of sensitivity.

A DBMS-Independent Web-based Query Learning System Providing Feedback Information on Student's Exercise (학습자 실습과정 정보를 제공하는 DBMS에 독립적인 웹 기반 질의 학습 시스템)

  • Kim, Taeyoung;Choe, Hyunjong
    • The Journal of Korean Association of Computer Education
    • /
    • v.6 no.2
    • /
    • pp.137-146
    • /
    • 2003
  • The Web programming techniques like CGI and server-sided script languages such as ASP, PHP and JSP have been used for developing on-line Web-based learning systems on SQL. But, the systems developed by using those techniques are dependent on the platforms on which the target DBMS's are located. Therefore, they can be hardly reused and maintained. In addition, it is not easy for them to provide a learner with the feedback information on processing his/her query and to give a teacher an opportunity of monitoring and guiding learner's learning process. In this paper, we propose an SQL learning system on the Web by using Java Applet and JDBC, which is independent on the target DBMS's. Moreover, it gives feedback information on learner's queries so that a teacher can monitor the learning process and teach them efficiently.

  • PDF

Danger Situations Alert System based U-Healthcare (유헬스케어 기반의 위험상황 알림 시스템)

  • Park, Byungdon;Yu, Donggyun;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.193-198
    • /
    • 2017
  • Recently, as interest in health increases, various wearable devices such as smart watch and smart band which can measure user's biometric information are being studied. Conventional wearable devices service the measured biometric information in a form that provides simple monitoring, disease prevention, and exercise amount. However, the user is Lack to deal with the dangerous situation. In this paper, we propose a hazard notification system to address these problems. The biometric information measured by the acceleration sensor and the heart rate sensor is transmitted to the application through the Arduino in real time. It identifies the risk situation through sensor priority measurement and risk situation identification algorithm. If a dangerous situation occurs, a notification message is sent to the guardian indicating the current location of the user. Therefore, it can be expected that if a dangerous situation occurs to a user who needs protection, he can respond promptly.

Structural identification of Humber Bridge for performance prognosis

  • Rahbari, R.;Niu, J.;Brownjohn, J.M.W.;Koo, K.Y.
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.665-682
    • /
    • 2015
  • Structural identification or St-Id is 'the parametric correlation of structural response characteristics predicted by a mathematical model with analogous characteristics derived from experimental measurements'. This paper describes a St-Id exercise on Humber Bridge that adopted a novel two-stage approach to first calibrate and then validate a mathematical model. This model was then used to predict effects of wind and temperature loads on global static deformation that would be practically impossible to observe. The first stage of the process was an ambient vibration survey in 2008 that used operational modal analysis to estimate a set of modes classified as vertical, torsional or lateral. In the more recent second stage a finite element model (FEM) was developed with an appropriate level of refinement to provide a corresponding set of modal properties. A series of manual adjustments to modal parameters such as cable tension and bearing stiffness resulted in a FEM that produced excellent correspondence for vertical and torsional modes, along with correspondence for the lower frequency lateral modes. In the third stage traffic, wind and temperature data along with deformation measurements from a sparse structural health monitoring system installed in 2011 were compared with equivalent predictions from the partially validated FEM. The match of static response between FEM and SHM data proved good enough for the FEM to be used to predict the un-measurable global deformed shape of the bridge due to vehicle and temperature effects but the FEM had limited capability to reproduce static effects of wind. In addition the FEM was used to show internal forces due to a heavy vehicle to to estimate the worst-case bearing movements under extreme combinations of wind, traffic and temperature loads. The paper shows that in this case, but with limitations, such a two-stage FEM calibration/validation process can be an effective tool for performance prognosis.

Development of Bib Pants Design and Pattern for Cycling Smart Wear (사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발)

  • Yunyoung, Kim;Byeongha, Ryu;Woojae, Lee;Kikwang, Lee;Rira, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.91-104
    • /
    • 2022
  • In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S-T8' > 'S-T10' > 'S-L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S-L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

Analytical Determination of Vitamin B12 Content in Infant and Toddler Milk Formulas by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

  • Lee, Jung-Hoon;Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.6
    • /
    • pp.765-771
    • /
    • 2015
  • The development of a sample preparation method and optimization of the analytical instrumentation conditions were performed for the determination of the vitamin B12 content in emulsified baby foods sold on the Korea market. After removal of the milk protein and fats by chloroform extraction and centrifugation, the vitamin B12 was water extracted from the sample. Following filtration of the solution through a nylon filter, the water-soluble extract was purified by solid-phase extraction using a Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). The solution eluted from the cartridge was dried under a stream of nitrogen gas and reconstituted with 1 mL of water. The sample solution was injected into an LC-MS/MS system after optimizing the mobile phase for vitamin B12 detection. The calibration curve showed good linearity with the coefficient of correlation (r2) value of 0.9999. The limit of detection was 0.03 µg/L and the limit of quantitation was 0.1 µg/L. The method of detection limit was 0.02 µg/kg. The vitamin B12 recovery from a spiking test was 99.62% for infant formula and 99.46% for cereal-based baby food. The sample preparation method developed in this study would be appropriate for the rapid determination of the vitamin B12 content in infant formula and baby foods with emulsified milk characteristics. The ability to obtain stable results more quickly and efficiently would also allow governments to exercise a more extensive quality control inspection and monitoring of products expected to contain vitamin B12. This method could be implemented in laboratories that require time and labor saving.

Effects of Induced Microcurrent Shoes on Fatigue and Pain in Painful Foot to Patients with Plantar Fascitis (족저근막염 환자의 미세전류발생 신발 착용이 족부 근피로 및 통증 완화에 미치는 영향)

  • Park, Rae-Joon;Choi, Sang-Joon;Cheng, Goh Ah;Cho, Jeong-Sun;Lee, Yoon-Mi;Cho, Yong-Ho;Park, So-Hyun;Cho, Mi-Suk
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • Purpose: This study was to investigate how induced microcurrent shoes affect relief of feet pain, which often occurs to persons who are more than fifty years old and how they prevent fatigue of feet generated during everyday life. The subjects of this study were comprised af five males and five females, who agreed with this research and ate more than fifty years old. And they all have plantar faciitis and pain in their feet. Methods: Subjects ware the induced microcurrent shoes far more than 4 hours everyday during the test. When they wore those shoes, they also wore the specially produced shacks made of silver-mixed thread and they were asked to avoid serious exercise. Prior to starting test and after the test, assessments were carried out two times. In the examination before the test, general shoes were used and in examination after the test, induced microcurrent shoes used. Muscle fatigue was measured by electromyography(MP150, Biopac, USA). When the walking rate of subjects on a treadmill was increased from 2.Km/h to 3Km/h for 10 minutes, muscle activities of a lower leg were measured during the whale walking process by MP150 remote monitoring system(TEL 100C). And pain was measured by VAS. Results: The results are as follows. 1. Comparisons of VAS before and after experimentation showed that degree of pain was significantly decreased(p < .05). 2. Degree of fatigue of Tibialis anterior was significantly decreased after 6 weeks of treatment(p < .05). 3. Degree of fatigue of Soleus was slightly decreased after 6 weeks of treatment, but did not show significant difference (p > .05). Conclusion: The above results suggest that induced microcurrent shoes is helpful decreasing fatigue of feet and relief of feet pain.

  • PDF