• 제목/요약/키워드: Exciting Magnetic Field

검색결과 46건 처리시간 0.022초

유도전동기의 자기여자 및 역률보상에 대한 연구 (A Research on Self-excitation and Power Factor Compensation of Induction Motor)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.236-240
    • /
    • 2014
  • Induction motor requires a rotating magnetic for rotation. Current required to generate the rotating magnetic field is magnetizing current. This magnetizing current is associated with the reactive power. This reactive power must be supplied from source side. Therefore, the power factor of the induction motor is low. So, the capacitor is installed on the motor terminals to compensate for the low power factor. Power supply company has recommended to maintain a high power factor to the customer. If the capacitor current is greater than the magnetizing current of the motor, there is a possibility that the self-excitation occurs. So it is necessary to calculate the optimal capacity capacitor current does not exceed the magnetizing current. In this study, we first compute the no-load current and the reactive power of the induction motor and then calculates the limit of the maximum power factor without causing self-excitation.

컨베이어벨트의 비접촉식 스틸코드파선 검사장치 개발 (Development of Non-contact Detector for Broken Cords of Steel-Cord Conveyor Belt)

  • 유재상;손봉호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2535-2537
    • /
    • 2000
  • In order to detect and monitor the broken cords of steel-cord belt from being damaged by impact of large lump of materials and the corrosion of steel cord, we developed a non-contact magnetic coil detection system. This measures the deterioration of reinforcing cables in steel cord conveyor belt which transport the ores in raw material plant. In this research, magnetic coil sensor of broken-cord detection system has exciting part and sensing part. The broken-cord detection system is operated by supplying a transmitter coil with electric power to generate magnetic field, and then the change of induced voltage is detected in each receiver coils due to resultant magnetic flux effected by the broken steel cords at the inside of the conveyor belt. By the informations such as the position and size of the broken steel cords obtained by SCBMS(Steel Cord Belt Monitoring System), it is expected that not only the span of belt life will be lengthened, but also this system can enable operators to plan scheduled maintenance and prevent the enlargement of damaged parts in steel cord belt at an early stage

  • PDF

Study of the Dependency of the Specific Power Absorption Rate on Several Characteristics of the Excitation Magnetic Signal when Irradiating a SPION-containing Ferrofluid

  • Rosales, Alejandra Mina;Aznar, Elena;Coll, Carmen;Mendoza, Ruben A. Garcia;Bojorge, A. Lorena Urbano;Gonzalez, Nazario Felix;Martinez-Manez, Ramon;del Pozo Guerrero, Francisco;Olmedo, Jose Javier Serrano
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.460-467
    • /
    • 2016
  • Magnetic hyperthermia mediated by superparamagnetic particles is mainly based in sinusoidal waveforms as excitation signals. Temperature changes are conventionally explained by rotation of the particles in the surrounding medium. This is a hypothesis quite questionable since habitual experimental setups only produce changes in the magnetic module, not in the field lines trajectories. Theoretical results were tested by changing the waveform of the exciting signal in order to compare non-sinusoidal signals against sinusoidal signals. Experiments were done at different frequencies: 200 KHz, 400 KHz, 600 KHz, 800 KHz and 1 MHz. Superparamagnetic Iron Oxide samples (SPION), made of magnetite ($Fe_3O_4$) and suspended in water (100 mg/ml), were used. Magnetic field strength varies from $0.1{\pm}0.015KA/m$ to $0.6{\pm}0.015KA/m$. In this study was observed that the power loss depends on the applied frequency: for 1 to 2.5 RMS current the responses for each signal are part of the higher section of the exponential function, and for 3.5 to 8 RMS current the response is clearly the decrement exponential function's tale (under $1{\times}10^3LER/gr$).

와전류(eddy-current)방법에 의한 비접촉 전기비저항 측정기술 개발 (The measurement for contactless eddy-current conductivity on Si wafer)

  • 박진습;유권상;류제천;유광민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.991-993
    • /
    • 1999
  • The method of measurement for contactless eddy-current conductivity using magnetic dipole field theory was suggested by M.C Chen[1], which calculate the eddy-current caused by exciting coil with Faraday's induction law. In this work, we have developed the apparatus for contactless measurement of conductivity or resistivity with the dipole field theory. The resistivity can be measured from several to a dozen $m{\Omega}{\cdot}cm$ range within maximum 30% error. At the high resistivity range above $100{\Omega}{\cdot}cm$, the standard deviation of measurement was very large as the induced voltage of sensing coil is small so it was difficult to measure the value precisely.

  • PDF

가역투자율 측정에 의한 터빈로터강의 비파괴적 잔여수명 평가 (Nondestructive Evaluation of Remanent Life of Turbine Rotor Steel by Measuring Reversible Magnetic Permeability)

  • 유권상;남승훈;김용일
    • 비파괴검사학회지
    • /
    • 제23권4호
    • /
    • pp.315-321
    • /
    • 2003
  • 고온, 고압에서 운용되고 있는 설비의 안전성을 평가하기 위해서는 사용시간 동안 열화된 물성을 정기적으로 점검하여 설비의 잔여수명을 평가해야 한다. 본 연구에서는 교류 섭동 자기장을 인가하여 구한 가역투자율 값을 이용하여 1Cr-1Mo-0.25V 강의 잔여수명을 평가하기 위한 자기적 방법을 제시하고자 한다. 이 방법은 자기이력곡선의 미분값인 가역투자율이 보자력에서 첨두 값을 갖는 특성을 이용하였으며, 측정원리는 교류 섭동 자기장의 주파수에 동조된 록-인 증폭기를 사용하여 탐지코일에 유도된 제 1 고조파의 전압을 측정하는 것이다. 가역투자율의 첨두값 간격 (peak interval of reversible magnetic permeability: PIRMP)과 비커스 경도는 열화가 진행됨에 따라 감소하였다 따라서 비커스 경도와 PIRMP상관관계에 의해 연화곡선을 구할 수 있고, 이 연화곡선에 의해 터빈로터 강의 잔여수명을 평가할 수 있다.

비접촉 축 진동 가진기의 모드 선택성 및 설계인자가 출력에 미치는 영향에 대한 실험적 검증 (Experimental Verification of Mode-selectivity and Effects of Parameters on Outputs in a Noncontact Vibration Exciter for a Shaft)

  • 이호철
    • 한국소음진동공학회논문집
    • /
    • 제21권10호
    • /
    • pp.924-933
    • /
    • 2011
  • The possibility of noncontact excitation of vibrations in a shaft was investigated in order to enable online structural health monitoring of a shaft during its rotating condition without stop operation. The proposed noncontact exciter was devised to exclusively generate one of two shaft vibration modes, so called longitudinal and flexural. Using the prototypes and a lot of experiments on them, it was proven that bias magnetic field, exciting voltage, center frequency, and geometry of yokes have crucial impacts on its output characteristics.

METEORITES: ROCKS FROM THE OUTER SPACE

  • Doh, Seong-Jae;Yu, Yong-Jae
    • 천문학회지
    • /
    • 제43권6호
    • /
    • pp.183-190
    • /
    • 2010
  • According to the historical documents and paintings in many civilizations, rocks that fell from the sky fascinated humans as the message from the God or supernaturals. Scientific progress allows humans to recognize these exciting extraterrestrial objects as meteorites. Meteorites contain a wealth of pivotal information regarding formation of the early Solar System. Meteorites also provide broader scientific insights on, for example, the origin of life, interplanetary transfer of life forms, massive depletion of biosphere on Earth, and evolution of lithosphere on Earth-like planetary bodies.

자기적 방법에 의한 터빈 로터강의 열화도 평가 (Degradation Evaluation of Turbine Rotor Using Magnetic Method)

  • 유권상;박진습;남승훈;김용일;유광민;류제천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1593-1595
    • /
    • 2000
  • We present a new procedure to evaluate the degradation in a lCr-lMo-0.25V steel. The method is based on the existence of the peak of reversible permeability in the differential magnetization around the coercive field strength. The apparatus is based on the detection of the voltage induced in a surface type coil using a lock-in amplifier tuned to a frequency to the exciting one. Results obtained the reversible permeability and Vickers hardness on the annealed samples show the peak interval of reversible permeability and Vickers hardness decreased as ageing time increased. The correlation between Vickers hardness and the peak interval of reversible permeability could well be evaluated non destructively.

  • PDF

토로이드형 분말코어의 Major B-H Loop 측정 (Major B-H Loop Measurement of Toroidal Shape Magnetic Powder Core)

  • 손대락
    • 한국자기학회지
    • /
    • 제24권3호
    • /
    • pp.76-80
    • /
    • 2014
  • 토로이드 형태의 자성분말합금 코어의 경우 major B-H loop을 측정하기 위해서는 수십 kA/m 이상의 높은 자화력을 인가하여야 한다. 이 경우 측정과정에서 일차코일에 권선된 에나멜 동선에서 발생하는 열 때문에 측정이 매우 어렵다. 본 연구에서는 토로이드 형태의 자성분말합금 코어 major B-H loop을 직접 측정할 수 있는 장치를 설계 제작하고, 그 성능을 측정하였다. 수십 kA/m 이상의 자화력을 인가하기 위하여 최대 전류가 $100A_P$인 전력 증폭기와 측정 시간 중에 높은 전류에 의하여 코일 권선에서 발생하는 열 문제를 해결하기 위하여 실시간으로 자기 이력 곡선을 측정 할 수 있게 실시간으로 B-H 신호를 디지털신호로 변환하여 컴퓨터 소프트웨어에서 자속밀도 B 와 자화력 H 값을 계산하고, 이 값들로 부터 주요 자기 특성인 최대자속밀도 $B_{max}$, 최대 자화력 $H_{max}$, 보자력 $H_c$, 잔류자속밀도 $B_r$ 및 형상인자(FF)를 계산하여 가상계측기(VI)창으로 표시 할 수 있게 하였다. 제작된 장치를 이용하여 외경이 134 mm, 내경이 77 mm, 높이가 42 mm인 자성분말코어에 일차 코일을 직경이 1 mm인 에나멜 동선을 401회 권선하고 이차 코일을 직경이 0.2 mm인 에나멜 동선 5회 권선하여 측정을 하여 본 결과 최대 인가 자기장을 50 kA/m까지 인가하면서 자기이력곡선을 측정 할 수 있었다.

자기공명영상진단기(磁氣共鳴影像診斷機)(MRI)의 보유현황(保有現況) 및 이용실태(利用實態)에 관한 조사연구(調査硏究) -부산시내(釜山市內) 3개(個) 병원(病院)을 중심(中心)으로- (A Study on the Status of Installation and Utilization of Magnetic Resonance Imaging in Korea)

  • 김경배;이만재
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권2호
    • /
    • pp.37-47
    • /
    • 1992
  • Magnetic Resonance Imaging(MRI) is one of the most expensive and sophisticated diagnostic tool and has been hailed as the most exciting event in medical imaging "since the introduction of X-rays", but a major disadvantage, high cost, is coming into focus especially in our country. To determine the status of distribution of MR imagers in Korea and to serve as a basic material for an efficient utilization of this Imaging machine, a retrospective survey of nationwide and regional(3 hospitals in Pusan) installations was performed. The results were as follows : 1. As of April 30, 1991, a total of 33 MRI units(24 for superconducting, 6 for permanent and 3 for resistive units) were set up and operated. 91% of the units were distributed in big cities with no one installation in 7 provinces among 12 provinces in our country. 85% of the units were imported. 2. Although 42.4% of the units were operated in Seoul, Taejeon had the best condition for the distribution of this imaging machine per population, hospital, and bed in Korea. 3. In Pusan : a) 5 units were operated with all superconducting magnet and medium magnetic field in type of machine. b) 80.1 % of the examinations were central nervous system(CNS). c) MRI examination occupied 1.4% of all radiographic examinations and the patients referred from other hospitals were composed of 23.4%% of all patients. 4. The average days under operating of MRI unit a week in Puasn were higher(5.5) than that of Seoul(4.5), but the average number of examinations and hours a week and a day, respectively(33, 8.4), was less than that of Seoul(57, 12.9). 5. The patients with positive MRI findings in a hospital(B) in Pusan was 74.5% on an average.

  • PDF