• Title/Summary/Keyword: Exciter Coil

Search Result 16, Processing Time 0.029 seconds

A Study on the Design of RFECT System for Ferromagnetic Pipelines (강자성체 배관 탐상용 RFECT System의 설계에 관한 연구)

  • Lee, Yu Ki;Kim, Hui Min;Park, Gwan Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.171-178
    • /
    • 2014
  • Remote Field Eddy Current Testing (RFECT), one of the ways which is a nondestructive testing using electromagnetic fields, can make up for Magnetic Flux Leakage (MFL) weaknesses and general Eddy Current Testing (ECT) weaknesses which is an occurrence of a huge friction force or disadvantage of detecting defects on the outer wall. So many of institutes and laboratories have studied on RFECT for the past 50 years. But There is a lack of discussion about a study on eddy current and magnetic field distributions in a pipe wall and designing of RFECT exciter coil. In this paper, eddy current and magnetic field distributions in a pipe wall and influence of altering variables are analyzed. Also, the optimal design algorithm about the RFECT Exciter coil are proposed, and influence on defect signals caused by alteration of its shape is analyzed.

Design of Shielded Encircling Send-Receive Type Pulsed Eddy Current Probe Using Numerical Analysis Method

  • Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.505-510
    • /
    • 2013
  • An encircling send-receive type pulsed eddy current (PEC) probe is designed for use in aluminum tube inspection. When bare receive coils located away from the exciter were used, the peak time of the signal did not change although the distance from the exciter increased. This is because the magnetic flux from the exciter coil directly affects the receive coil signal. Therefore, in this work, both the exciter and the sensor coils were shielded in order to reduce the influence of direct flux from the exciter coil. Numerical simulation with the designed shielded encircling PEC probe showed the corresponding increase of the peak time as the sensor distance increased. Ferrite and carbon steel shields were compared and results of the ferrite shielding showed a slightly stronger peak value and a quicker peak time than those of the carbon steel shielding. Simulation results showed that the peak value increased as the defect size (such as depth and length) increased regardless of the sensor location. To decide a proper sensor location, the sensitivity of the peak value to defect size variation was investigated and found that the normalized peak value was more sensitive to defect size variation when the sensor was located closer to the exciter.

Design and Evaluation of a Vibration Exciter for the Flow Resonance (유동공진을 위한 가진기 설계 및 평가)

  • Nam, Yoon-Su;Choi, Jae-Hyuck
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.141-147
    • /
    • 2001
  • A heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate an air turbulence which has the natural shedding frequency of a heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its validity is verified by the comparison with experimental data. Values of some unko주 system parameters in the analytic model are estimated through the system identification approach. based on this mathematical model, a high bandwidth vibration exciter is designed using feedback control. During the experimental verification phased, it turns out the high frequency modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

Vibration Exciter Design for Flow Resonance (유동공진을 위한 가진기 설계)

  • Nam, Yoon-su;Choi, Jae-hyuck
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.125-130
    • /
    • 2000
  • Heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate air turbulence which has the natural shedding frequency of heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its validity is verified by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, a high bandwidth vibration phase, it turns out the high modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

Design of an Encircling-type Probe for the Inspection of Rods using Remote Field Eddy Current Effects (원격장와전류 효과를 이용한 봉 구조물 탐상용 외부탐촉자 설계)

  • Shin, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.290-292
    • /
    • 1999
  • 핵연료봉이나 제어봉과 같은 봉구조물의 검사를 위하여 원격장와전류 효과를 낼 수 있는 탐촉자를 설계하고 탐상주파수를 유한요소해석을 통해 설정하였다. 핵연료봉을 대상으로 한 해석에서 exciter coil 주변을 차폐하고 500kHz의 주파수를 사용한 결과 전위계곡과 위상매듭의 존재가 나타나 원격장와전류 효과가 구현되었음을 확인하였다. exciter와 sensor coil로 이루어진 탐촉자를 이동시키면서 예측한 탐상신호에서는 센서를 원격장 의치에 고정시켰을 때, 결함이 센서를 지날 때의 위상신호와 결함이 exciter를 지날 때의 위상신호가 서로 달리 나타났다. 또한, 외부결함과 내부결함이 센서를 지날 때의 위상지연은 작지만 서로 반대의 경향으로 나타났으며, 두 종류의 결함이 exciter를 지날 때는 위상지연이 상대적으로 크게 줄어들고 외부/내부 결함에 상관없이 신호가 비슷하게 나타남을 볼 수 있었다. 이러한 신호형태는 자성체 관의 탐상에서 내, 외부 결함신호가 구별이 안되고, 동일한 위상신호가 항상 쌍으로 나타나는 것과 비교할 때, 신호해석을 훨씬 수월하게 해 줄 수 있을 것이라고 판단된다.

  • PDF

Analysis on the Measured Natural Frequencies Due to the Structure-Exciter Interaction (구조물-가진기 상호작용에 의한 공진주파수 변동에 대한 해석)

  • Han, Sang-Bo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.7
    • /
    • pp.2108-2117
    • /
    • 1996
  • The purpose of this paper is to investigate the influence of the exciter attached for the measurement of natural frequencies when extracting the frequency response functions of the test structure in experimental modal analysis. The procedure is first to model the attached exciter as an additional degree of freedom system and next to verify the suggested model by experimentally extracting the natural frequencies of the test structure with various values of exciter mass, stinger stiffness and attachment position of the exciter on the test structure. It is concluded that as additional degree of freedom system which includes the natural frequency of the exciter itself and axial stiffness of stinger should be considered to quantatively define the coupling effects of structure-exciter interaction on the measured natural frequencies. It is not the mass of the exciter itself but the coupling effect of the additional degree of freedom mass-spring system consisting of exciter body and armature coil that characterizes the natural frequency deviation. Therefore, when the natural frequency of this additional mass-spring system is outside of the test frequency range, the coupling effect of structure-exciter interaction can be minimized.

The Development of Vibration Exciter Using Strain Displacement Estimator for Flow Resonance (스트레인 게이지 변위 추정기를 사용한 유동공진 가진기 개발)

  • Choi, Jae-hyuck;Nam, Yoon-su
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.125-132
    • /
    • 2001
  • Heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate air turbulence which has the natural shedding frequency of heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its' validity is verified by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, the vibration exciter using strain displacement estimator is developed. And in the experiment, the feedback control is used. During the experimental verification phase, it turns out the high modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

Fabrication and Test of a Cell Exciter Actuated by an Electromagnetic Force for the Chondrogenic Differentiation of Mesenchymal Stem Cells

  • Park, Sin-Wook;Sim, Woo-Young;Park, Sang-Hyug;Min, Byoung-Hyun;Park, So-Ra;Yang, Sang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.176-180
    • /
    • 2004
  • This paper presents the fabrication and test of a micro cell exciter actuated by an electromagnetic force for the study on the chondrogenic differentiation of rabbit mesenchymal stem cells (MSCs). The micro cell exciter is designed to apply compressive loading to the alginate gel mixed with the MSCs. The magnetic cell exciter consists of an actuator component and a cartridge-type chamber component. An actuator is composed of a permanent magnet, a core and a coil. The chamber has seven PMMA wells and a cell culture Petri dish. Two types of alginate gels were stimulated by the cell exciters for 10 minutes every 12 hours for 7 days. In order to determine the expression of these matrix components during differentiation, RT-PCR analysis was performed. Collagen type II was expressed in the MSCs subjected to the compressive stimulation.

Vibration Exciter Design for Flow Resonance with a Displacement Estimator Using Strain Gage (스트레인 게이지 변위추정 센서를 사용한 유동공진 가진기 설계)

  • Nam, Yun-Su;Choe, Jae-Hyeok;Gang, Byeong-Ha
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1874-1881
    • /
    • 2002
  • Heat dissipation technology using the flow resonant phenomenon is a kind of a new concept in the heat transfer area. A vibration exciter is needed to enhance air flow mixing which has the natural shedding frequency of thermal system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator with a displacement estimator using strain gage. An analytical dynamic model for this mechanical vibration exciter is presented and its validity is checked by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, the vibration exciter using strain displacement estimator is developed. During the experimental verification phase, it turns out the high modal resonant characteristics of a vibrating plate are a major barrier against obtaining a high bandwidth vibration exciter.

The Micro Electromagnetic Force Measurement of Voice-coil Actuator using Semiconductor Piezoresistive Type Vibration Sensor (실리콘 압저항형 진동 센서를 이용한 Voice-coil형 구동기의 미소 전자력 측정)

  • Gwon, Gi-Jin;Lee, Gi-Chan;Park, Se-Gwang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.147-152
    • /
    • 1999
  • Semiconductor piezoresistive type vibration sensor was fabricated by using semiconductor process and micromachining technology. To measure the micro electromagnetic force between coil and magnet, fabricated vibration sensor was used. Toapply micro electromagnetic force produced from the micro exciter, small-sized NdFeB permanent magnet was attached on the mass of the fabricated vibration sensor. The measured electromagnetic force are about 5~180dyne when the applied sinusoidal current of 1KHz in the range of 1.5~8mA. The measurement of micro electromagnetic forcewas performed by changing the distance between coil and magnet. Output characteristics of micro electromagnetic force according to the applied coil current were linear. Furthermore, output results were used to get the transfer constant that is important to decide the efficiency and the performance of the coil and magnet.

  • PDF