동기발전기용 디지털 여자시스템 고성능 제어 (High Performance Control of Digital Excitation System for Synchronous Generator)

  • 서민성;류동균;김이훈;김준호;원충연;배기훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.763-768
    • /
    • 2002
  • In this paper digitally based excitation systems for the synchronous brushless generators are presented. System configuration, control functions with their structure functions are also shown. The control system has two feedback loops: main one based on a generator's voltage with digital controller and inner one based on excitation voltage of the exciter with analog controller. Usually the generator regulation of voltage Is made with transducers for the voltage measurement. This paper shows technique of measuring the voltage without harmonics affect, using Park's equation transformation.

  • PDF

전압 이중 검출법에 의한 독립형 엔진-발전기 시스템 응답특성 개선 (Dynamic Response Improvement of Stand Alone Engine-Generator System using Double Voltage Detection Method)

  • 이동희;안진우
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1195-1199
    • /
    • 2008
  • In this paper, peak detector of generator's output voltage and variable gain controller are introduced for a fast dynamic response. The conventional r,m.s, signal detected has inherent time delay, and the dynamic response of generator using conventional PID controller has some problem in sudden load change. In this paper, the peak detector and signal selector with variable gain controller is used to overcome this problem. The main controller can check the voltage state from the peak detector. When a sudden load change, the over-voltage and under-voltage signal from peak detector change the controller's gain and exciter's current reference. The proposed scheme can improve the dynamic response, which is verified from experimental test of 200kW diesel engine-generator.

A 캐패시터 자력식 삼상동기발전기에 관한 연구 (Study on the Capacitor-self-excited Three-phase Synchronous Generator)

  • 정연택;김영동
    • 대한전기학회논문지
    • /
    • 제33권11호
    • /
    • pp.425-432
    • /
    • 1984
  • This paper is to propse a new self-excitation method of synchronous generator. Instead of conventional exciter of synchronous generator, the additional winding which is arranged in addition to the armature winding, is used in this generator. The output terminal of the additional winding is connected to a capacitor and to a full wave rectifier in series. In this configuration, one source double excitation which is composed of capacitor-self-excitation by lead urrent and direct current excitation by rectifier, is induced. The result is that` The excetation efficency is improved greatly and output waveform is improved also. In three-phase synchronous generator using the new method of the one source double excitation, voltage element (shunt characteristics) and current element (series characteristics)are compounded in scalar by adapting star-point-open-rectifier system. The result is as following` The effect of load power factor angle on voltage regulation is reduced greatly, compound characteristics is become manifold by controlling capacity of capacitor, and transient response is improved.

  • PDF

파워흐름해석법의 신뢰성 검증을 위한 원통형 구조물의 진동실험 (Vibration Experiments of the Cylindrical Structure for Verifying the Reliability of Power Flow Finite Element Method)

  • 이호원;홍석윤;박영호;길현권;김창열;전재진;류정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.290-297
    • /
    • 2002
  • Vibration experiments have been performed to observe the analytic characteristics of power How finite element method(PFFEM) for the reinforced cylindrical structure. For this, the vibration experimental results are compared with the numerical solutions obtained by PFFEM in medium-to-high frequency ranges. Input Power into the experimental structure is measured using the impedance head adhered to the exciter, and that input power is used for the vibration analysis. Using the developed PFFEM program(PFADS), the reinforced cylindrical structure modeled by beam and plate elements is analyzed, and very reliable results for PFFEM are obtained by the comparisons of the experimental results.

  • PDF

진동-음향 상반 원리에 이용되는 음원의 유효 면적 측정 (The Application of Equivalent Area to the Volume Velocity for Using the Vibro-acoustical Reciprocity)

  • 고강호
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.943-948
    • /
    • 1999
  • This paper proposes a feasible and effective method for measuring the mechanical-acoustic transfer function by the application of equivalent area and velocity transfer function, a manifestation of the vibro-acoustical reciprocity principle. On the contrary to the volume velocity used in traditional method, the equivalent area is a peculiar raidation characteristics of sound sources and not influenced by any input signal for driving sound source. This invariant property of equivalent area can get rid of boresome works to measure the volume velocity of a sound source every time the driving signal is changed. Moreover, this method has a remarkable advantage to use a general loudspeaker as an accoustic exciter without the assumption of point source and can be applied to all kinds of sound sources even if they are not omni-directional sources.

  • PDF

팬 작동에 따른 비팅성 아이들 진동 평가 (Evaluation of idle vibration beated by cooling fan imbalance)

  • 박진한;안세진;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.247-249
    • /
    • 2014
  • The beating phenomenon occurs because of various causes, when idle vibration was happened. In this study, the beating phenomenon was divided into several parameters and controlled by the parameter. It was hypothesized that the beating parameter is related to discomfort of idle vibration. The three-down one-up method was performed for evaluating discomfort of controlled vibrations, which is widely used in the field of psychophysics. As a result in pilot test, a subject responds beating vibration more discomfort than normal idle vibration. In the future, the study will be implemented to know how much the parameters of beating signal affect to the discomfort at idle vibration in passenger vehicle.

  • PDF

대형 공진주 시험 장비의 적용 (Adoption of the large scale free-free resonant column test)

  • 박인범;박철수;목영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.626-633
    • /
    • 2009
  • A large scale resonant column testing equipment is under development. The would-be equipment is aiming to test 150mm-diameter specimens, which can contain as large a grain size as 25mm. Such a large specimen is hardly excitated with the existing fixed-free end condition because the torsional force cannot be effectively coupled to the specimen. The specimen will be rather resonated with free-free condition and the scheme is implemented with a rotational bearing installed between coil-magnet exciter and base pedestal. Presently the equipment was assembled and is under calibration with a cylindrical brass specimen.

  • PDF

EXCITATION SYSTEM MODERNIZATION OF THERMAL POWER PLANT

  • Kim, Chan-Ki;Kim, Jang-Mok;Rhew, Ho-Sun
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2024-2026
    • /
    • 1998
  • Many power plants built 20-30 years ago are facing problems associated with the excitation system used for controlling generator output voltage. After years of reliable operation, generation is experiencing increased down time due to maintenance associated with the exciting excitation equipment. Reliability of the excitation system has become an issue, especially where many of these generation plants may be critical to the internal processes used for manufacturing. Wear out mechanisms such as those associated with the wire wound rheostat the electromechanical voltage regulator, insulation failures of the rotating exciter and commutator deterioration have become real problems typical of many older installations. These are some of the issues that are affecting system reliability for older power plants. This paper will address typical problems associated with the old excitation systems and the justification for a replacement static excitation system used in many Paper Mills.

  • PDF

제동력 향상을 위한 FACTS기기제어 (FACTS controller design for improving Power System damping)

  • 윤종수;이근준;문건우;윤석호;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.835-837
    • /
    • 1997
  • This paper presents a control system design for the STATCON of FACTS devices by LQR, LQG control scheme to enhance small-signal stability in the power system, the feature of this FACTS controller is coordinated with generator exciter controller(AVR, PSS) to improve the total power system stability and performance.

  • PDF

동하중재하시 지반진동에 관한 실험적 연구 (An Experimental Study of Ground Motion under the Dynamic Load)

  • 김문겸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.126-131
    • /
    • 1997
  • Recently, the ground motion occurred by vehicles or trains has been recognized one of the major factors of damage of structures nearly the motion source. To isolate the environments from ground motions, it is necessary to understand the wave propagation in half spaces. Especially, Rayleigh wave is the primary concern because it transmits a major portion of the total source energy and decays the energy more slowly with response to distance than the other waves. In this study, the preliminary data(wave length and damping effect) to design the isolating system are obtained. For this, a field dynamic test is performed, using the exciter which can generate the 100kN vertical cyclic load in the range of 1-60 Hz is used. The fifteen accelerometers to measure the ground response are set up in 3 radial direction at intervals of 10 meters in each row. The wave lengths are calculated using the distance and the phase between the measuring points. The damping effects of the Rayleigh-wave are also observed from the experiments.

  • PDF