• 제목/요약/키워드: Exchangeable contraction

검색결과 3건 처리시간 0.023초

H대학교 아음속 풍동 개념설계 (Concept Design of a H.A.U.'s Subsonic Wind Tunnel)

  • 장조원;전창수;김문상;이열;문희장;송병흠;김학봉
    • 한국항공운항학회지
    • /
    • 제13권4호
    • /
    • pp.92-99
    • /
    • 2005
  • A closed-circuit type wind tunnel is designed, which has a test section with the dimensions $1.2(W){\times}1.2(H){\times}3.4(L)$. A subsonic wind tunnel is designed to improves educational circumstances and promote ground tests. It is constituted of an exchangeable test section, first and second diffusers, a fan, a settling chamber, a contraction, and 4 corners. The maximum velocity in the test section is 70m/s and the contraction ratio is 6.25:1. Input power in the wind tunnel is about 96.1 kw (128.8 hp) and its energy ratio is 3.89. It has the dimension of about $7.4(W){\times}3.6(H){\times}21.7m(L)$. The wind tunnel designed in this investigation will be an effective educational and investigational equipment.

  • PDF

유동센서 보정용 캘리브레이션 제트 시스템 개발 (Development of Calibration Jet System for Calibrating a Flow Sensor)

  • 장조원;변영환
    • 한국항공운항학회지
    • /
    • 제11권1호
    • /
    • pp.41-55
    • /
    • 2003
  • A calibration jet system using separate blower is developed to calibrate a flow sensor effectively. Designed open circuit type mini calibration jet system, which has the dimension of $0.5m(W){\times}1.17m(H)$ is small compared with conventional calibration jet systems. The exit of nozzle has exchangeable contractions with a cross section area of $38.5cm^2$ , and a cross section area of $113.1cm^2$, respectively. The ranges of wind speed at exit of exchangeable nozzles are $7.5{\sim}42\;m/s$ and $1.8{\sim}16.5\;m/s$, respectively. The input power for the high pressure blower is 1.18kW. The turning vanes for corner was rolled flat plate parallel to the flow direction. The flow conditioning screen was located immediately downstream of the wide-angle diffuser. The honeycomb and two flow conditioning screens were located in the stagnation chamber. From the economical point of view and the simplicity of the calibration jet system set up and handling, it can be said that the developed calibration jet system is an effective calibration jet system. This system can also be used to calibrate the flow sensor with high resolution.

  • PDF

몬모리노나이트와 란탄족 원소들과의 인터카레이숀에 관한 연구 (Studies on the Intercalation between Montmorillonite and Lanthanides)

  • 하영구
    • 대한화학회지
    • /
    • 제30권5호
    • /
    • pp.488-492
    • /
    • 1986
  • 경북 원성군 감포 78에서 산출되는 벤토나이 중 몬모리노나이트를 분리하여 Ca, Mg-형을 NaCl용액으로 처리하여 Na-형 몬모리노나이트를 만들었다. 이때 가장 적당한 조건은 0.05M NaCl용액으로 80${\circ}C$에서 24시간 반응시켜 치환되는 $Ca^{2+}$, $Mg^{2+}$량을 EDTA로 적정하여 양이온 교환 용량을 구하였다. Na-형에 $Ln^{3+}$이온용액과 같은 조건하에서 반응시켜 $Ln^{3+}$-형 몬모리노나이트를 만들었다. 치환되는 량은 $Ln^{3+}$이온들의 이온 크기에는 무관함을 알 수 있었고, X-선 회절 실험결과 순수한 몬모리노나이트를 얻을 수 있음을 밝혔고, 또한 $Ln^{3+}$형은 새로운 결정모양이 되는 것을 알 수 있었다. 이는 단순한 틈새끼우기 반응이 아니 새로운 결정형이 생성됨을 알 수 있다.

  • PDF