• Title/Summary/Keyword: Exchangeable contraction

Search Result 3, Processing Time 0.017 seconds

Concept Design of a H.A.U.'s Subsonic Wind Tunnel (H대학교 아음속 풍동 개념설계)

  • Chang, J.W.;Jeon, C.S.;Kim, M.S.;Lee, Y.;Moon, H.J.;Song, B.H.;Kim, H.B.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.13 no.4
    • /
    • pp.92-99
    • /
    • 2005
  • A closed-circuit type wind tunnel is designed, which has a test section with the dimensions $1.2(W){\times}1.2(H){\times}3.4(L)$. A subsonic wind tunnel is designed to improves educational circumstances and promote ground tests. It is constituted of an exchangeable test section, first and second diffusers, a fan, a settling chamber, a contraction, and 4 corners. The maximum velocity in the test section is 70m/s and the contraction ratio is 6.25:1. Input power in the wind tunnel is about 96.1 kw (128.8 hp) and its energy ratio is 3.89. It has the dimension of about $7.4(W){\times}3.6(H){\times}21.7m(L)$. The wind tunnel designed in this investigation will be an effective educational and investigational equipment.

  • PDF

Development of Calibration Jet System for Calibrating a Flow Sensor (유동센서 보정용 캘리브레이션 제트 시스템 개발)

  • Chang, J.W.;Byun, Y.H.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.11 no.1
    • /
    • pp.41-55
    • /
    • 2003
  • A calibration jet system using separate blower is developed to calibrate a flow sensor effectively. Designed open circuit type mini calibration jet system, which has the dimension of $0.5m(W){\times}1.17m(H)$ is small compared with conventional calibration jet systems. The exit of nozzle has exchangeable contractions with a cross section area of $38.5cm^2$ , and a cross section area of $113.1cm^2$, respectively. The ranges of wind speed at exit of exchangeable nozzles are $7.5{\sim}42\;m/s$ and $1.8{\sim}16.5\;m/s$, respectively. The input power for the high pressure blower is 1.18kW. The turning vanes for corner was rolled flat plate parallel to the flow direction. The flow conditioning screen was located immediately downstream of the wide-angle diffuser. The honeycomb and two flow conditioning screens were located in the stagnation chamber. From the economical point of view and the simplicity of the calibration jet system set up and handling, it can be said that the developed calibration jet system is an effective calibration jet system. This system can also be used to calibrate the flow sensor with high resolution.

  • PDF

Studies on the Intercalation between Montmorillonite and Lanthanides (몬모리노나이트와 란탄족 원소들과의 인터카레이숀에 관한 연구)

  • Young Gu Ha
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.488-492
    • /
    • 1986
  • The $Ca^{++}$ and $Mg^{++}$ released during Ca, Mg-Na exchange on Kampo 78 montmorillonite which was treated with various concentrations of NaCl solution, were measured with EDTA titration metbod in the leaching solutions. Lanthanide montmorillonite was prepared with various neutral lanthanide ions from sodium montmorillonite in which the exchangeable ions are displaced from the exchanger, such as the displacement of $Na^+$ by $Ln^{3+}$ ions, Cation exchange capacity (CEC) is determined on remaining lanthanides in the leaching solutions with E. D. T. A titration method. As a results of this study, there were no difference of C. E. C in series of lanthanide contraction, but C. E. C depends on charge density of montmorillonite. When we conformed the structure of Ln-montmorillonite by X-ray diffraction. It was found that there was much difference of pattern between Na-montmorillonite and Ln-montmorillonite.

  • PDF