• Title/Summary/Keyword: Exchange times

Search Result 814, Processing Time 0.03 seconds

The Determinants of Future Bank Stock Returns in Eight Asian Countries

  • An, Jiyoun;Na, Sung-O
    • East Asian Economic Review
    • /
    • v.18 no.3
    • /
    • pp.253-276
    • /
    • 2014
  • We examine which traditional asset pricing variables together with bank-specific accounting variables explain the cross-sectional variation of future bank stock returns, using a firm-level data of eight Asian countries. Our empirical evidence shows that exchange rate risk, firm size, the book-to-market ratio, and the net income ratio are important in explaining future bank stock returns during normal times. However, during the Global Financial Crisis period, different variables such as local market beta, illiquidity risk, equity ratio, and off-balance sheets ratio were statistically significant. Thus, researchers and policy practitioners should monitor these variables during normal times as well as during times of crisis.

The Separation of the Impurities in Bismuth Metal by Ion Exchange Resins and Colorimetric Determination (이온交換樹脂에 依한 蒼鉛 中 不純物의 分離定量 (I))

  • Park, Myon-Yong
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.2
    • /
    • pp.47-50
    • /
    • 1968
  • Two methods for separation of the impurities from bismuth metal have been found by the use of Dowex $1{\times}4,$ anion exchange resins. The first method is that Dowex $1{\times}4$ resins are packed into the two stage columns (height of under stage is 22cm and upper stage is 3cm, and diameter of columns are 1.5cm), and the impurities of Pb(II), Ag(I) and Cu(II) are separated by the eluent of 7.5M HCl soln, Zn(II), Fe(III) by 0.5M HCl solns, and Te(IV) in the upper stage by 2M NaOH soln. Remained Au(III) in the upper stage is determined by the ignition with resins. The 2nd method is that for the separation of all the impurities simultaneously the same resins are packed into single stage column(height is 10cm and diameter is 1.5cm), and all the impurities of Pb(II), Zn(II), Cu(II), Fe(III) and Ag(I) are eluted by the eluent of 0.5M HCl soln. Separated impurities are determined by the colorimetry.

  • PDF

Survey on Actual Wearing and Size Dissatisfaction with Jeans for Upper Grade Elementary School Girls (학령 후기 여아의 청바지 착용실태 및 치수 불만족 조사)

  • Kim, Hea suk;Lee, Jeong yim
    • Fashion & Textile Research Journal
    • /
    • v.21 no.6
    • /
    • pp.813-820
    • /
    • 2019
  • This study identified actual wearing and size dissatisfaction with jeans worn by upper grade elementary school girls. A survey was conducted on 147 10~12-year-old girls in order to collect basic data to design a slim fit jeans pattern for upper grade elementary school girls. The result of the study are as follows. Upper grade elementary school girls wore jeans at least once a week, 46.9% were 1~2 times, 31.3% were 3~4 times and 21.8% were more than 5 times per week. The size of the jeans they wear was often one size or two sizes larger than the actual height section. Upper grade elementary school girls preferred jeans that fit well and allow for a full range of motion; in addition, waist and hip measurements were important criteria when selecting size. The preferred length of jeans was those that go to the ankle along with slim-style jeans made of "cotton+spandex". In terms of dissatisfaction with jeans, upper grade elementary school girls showed discomfort when the lower back waistline slipped when sitting and when there was a tight crotch area. In addition, cases of exchange or return were found to be due to fit, including waist, hip or thigh measurements even when the area most repaired is was the pant length.ired is pant length, cases of exchange or return were found to be due to fit, including waist, hip, or thigh measurements.

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF

A Study of the Trait of Leadership Failure Using Failure Knowledge (실패지식을 활용한 리더십 실패 특성 도출에 관한 연구)

  • Shim, Hyung-Seok;Hong, Sun-Gwan
    • Knowledge Management Research
    • /
    • v.15 no.3
    • /
    • pp.1-12
    • /
    • 2014
  • It is tried to draw the failure traits of leadership by extracting leadership parts from previous failure studies and including some parts which mention failure leadership among leadership-related books. All of 5 patterns are drawn through total 13 types of study data. From 'insensitive to change' and authoritarianism which is mentioned 8 times in such 13 studies, to 'interpersonal problem', which is mentioned five times, traits which are mentioned at least five times are selected. There are drawn 5 traits including ${\Delta}$ authoritarianism ${\Delta}insensitive$ to change ${\Delta}lack$ of executive ability ${\Delta}populism$ and ${\Delta}interpersonal$ problem. As being examined in these 5 types of failure traits, the failure of leadership is ultimately happened because of communication heading for the inside without any communication(exchange) to the outside. That is, it is understood that authoritarian leaders don't perceive change correctly but make a wrong communication (populism) or break down communication. Additionally, the executive ability is to perform actually one's idea and to be achieved through incessant communication with members. Compared with other various studies to draw failure factors, these leadership traits have something in common. In the previous researches conducted the study of general failure factors, ${\Delta}adherence$ to preexisting business and resistance to change ${\Delta}unfeasible$ expansion strategy ${\Delta}blind$ faith in successful technology and innovation and ${\Delta}insufficiency$ to grasp competitor(consumer) are pointed out as the failure factors. It is deemed that these are happened because organizational management is headed for the inside without any communication (exchange) to the external environments. Matters unfolded through this paper until now are an attempt to apply the failure knowledge to a leadership part which is an individual field in business administration. It is considered that this study will be complemented through additional case study or quantitative analysis in the future.

  • PDF

The Comparison on Treatment Method of Liquid Radioactive Waste in Yonggwang #3&4 and #5&6 (영광 3&4와 5&6호기에서 액체 방사성폐기물 처리방법의 비교)

  • Yeom, Yu-Seon;Kim, Soong-Pyung;Lee, Seung-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.219-230
    • /
    • 2004
  • Most of the low-level liquid radioactive wastes generated from PWR plants are classified into high or low total suspended solid(HTDS or LTDS), and into radiochemical and radioactive laundry waste. Although the evaporation process has a high decontami- nation ability, it has several problems such as corrosion, foam, and congestion. A new liquid waste disposal process using the ion-exchange demineralizer(IED), instead of the current evaporation process, has been introduced into the Yonggwang NPP #5 and 6. These two methods have been compared to understand the differences in this study. Aspects compared here were the released radioactivity amount of the liquid radioactive wastes, the dose of off-site residents, the decontamination factor, and the amount of the solid radioactive wastes. The IED system is designed to discharge higher radioactivity about 20% than the evaporating system, and the actual radioactivity released from the evaporating and IED system were 0.473mCi and 1.098mCi, respectively. The radioactivity released from the IED was 2.32 times higher than that of the evaporating system. The dose of off-site residents was $2.97{\times}10^{-6}$mSv for the evaporating system, and $6.47{\times}10^{-6}$mSv for IED. The decontamination factor(DF) of the evaporator is, in most cases, far lower than the lower limits of detection(LLD) with the Ge-Li detector. Due to the low concentration of the liquid wastes collected from the liquid waste system, the decontamination factor of IED is very low. Since there is not enough data on the amount of solid radioactive wastes generated by the evaporation system, the comparison on these two systems has been conducted on the basis of the design, and the comparison result was that the evaporating system generated more wastes about 40% than IED.

  • PDF

Synthesis of Aminated PP-g-styrene Fibrous Ion-Exchanger for Separation of Boron from Ground-Water (지하수로부터 붕소이온 분리를 위한 아민화 PP-g-styrene 이온교환체 섬유의 합성과 붕소 음이온 흡착에 관한 연구)

  • Hwang, Taek-Sung;Lee, Jin-Hyok;Lee, Myun-Joo
    • Polymer(Korea)
    • /
    • v.25 no.4
    • /
    • pp.451-459
    • /
    • 2001
  • Fabric ion-exchanger, aminated PP-g-styrene was synthesized with styrene monomer onto PP staple fiber by pre-irradiational grafting with E-beam and subsequent chloromethylation and amination. Degree of grafting was increased with increasing the styrene monomer concentration and the highest degree of grafting was obtained 118% at a monomer concentration of 80% styrene. Optimum condition of Mohr's salt and sulphuric acid were 1.0 ${\times}\;10^{-3}$ M and 0.1 M. Amount of amination was increased with increasing degree of grafting. Swelling ratio of aminated PP-g styrene was higher than that of trunk polymer. Ion-exchange capacity was 6.7 meq/g, which was three times greater than commercial ion-exchanger. Optimum condition of baron ion adsorption was pH 4 and amount of adsorption were increased with increasing the amount of amination.

  • PDF

Temperature-Range-Dependent Optimization of Noninvasive MR Thermometry Methods (온도범위에 따른 비침습적 자기공명 온도측정방법의 최적화)

  • Kim, Jong-Min;Kumar, Suchit;Jo, Young-Seung;Park, Joshua Haekyun;Kim, Jeong-Hee;Lee, Chulhyun;Oh, Chang-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.241-250
    • /
    • 2015
  • Noninvasive temperature monitoring is feasible with Magnetic Resonance Imaging (MRI) based on temperature sensitive MR parameters such as $T_1$ and $T_2$ relaxation times, Proton Resonance Frequency shift (PRFs), diffusion, exchange process, magnetization transfer contrast, chemical exchange saturation transfer, etc. While the temperature monitoring is very useful to guide the thermal treatment such as RF hyperthermia or thermal ablation, the optimization of the MR thermometry method is essential because the range of temperature measurement depends on the choice of the measurement methods. Useful temperature range depends on the purpose of treatment methods, for example, $42^{\circ}C$ to $45^{\circ}C$ for RF hyperthermia and over $50^{\circ}C$ for thermal ablation. In this paper, MR thermometry methods using $T_1$ and $T_2$ relaxation times and PRFs-based MR thermometry are tried on a 3.0 T MRI system and their results are reported and compared. In addition, the scanning protocol and temperature calculation algorithms from $T_1$ and $T_2$ relaxation times and PRFs are optimized for the different temperature ranges for the purpose of RF hyperthermia and/or thermal ablation.

Heat Recovery Characteristics of the Exhaust Heat Recovery System with Heat Pipe Unit Attached to the Hot Air Heater in the Greenhouse (히트파이프를 이용한 온풍난방기 배기열회수 시스템의 열회수 특성)

  • Kang, K. C.;Kim, Y. J.;Ryou, Y. S.;Baek, Y.;Rhee, K. J.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.441-448
    • /
    • 2001
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat capacity of the oil burred. In order to recover the heat of this exhaust gas and to use for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The system consisted of a heat exchanger made of heat pipes, ø15.88${\times}$600mm located in the rectangular box of 675(L)${\times}$425(W)${\times}$370(H)mm, an air suction fan and air ducts. The number of heat pipe was 60, calculated considering the heat exchange amount between exhaust gas and air and heat transfer capacity of a heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/h depending on the inlet air temperature of 12 to -12˚at air flow rate of 1.100㎥/h. The temperature of the exhaust gas left the heat exchanger dropped to 100$^{\circ}C$ from 270$^{\circ}C$ after the heat exchange between the suction air and the exhaust gas.

  • PDF

Roles of $Na^+\;-Ca^{2+}$ Exchange in the Negative Force-Frequency Relationship

  • Ko, Chang-Mann;Kim, Soon-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.6
    • /
    • pp.715-724
    • /
    • 1998
  • Frequency-force relationships (FFR) were studied in electrically field stimulated rat left atria (LA) by reducing the stimulation frequency from resting 3 Hz to test frequencies (0.1-1 Hz) for 5 minutes. The twitch amplitudes of LA elicited the typical negative staircases with 3-phased changes: the initial rapid increase, the second decrease and the following plateau at test frequencies. Verapamil $(3{\times}10^{-5}\;M)$ pretreatment elicited frequency-dependent suppression of the twitch amplitudes, exaggerating the negative staircase. Monensin pretreatment enhanced not the peak but the plateau amplitudes in a concentration-dependent manner. When the $Na^+-Ca^{2+}$ exchange was blocked by $Na^+\;and\;Ca^{2+}$ depletion in the Krebs Hensleit buffer (0 $Na^+-0\;Ca^{2+}$ KHB), the twitch amplitudes increased in a frequency-dependent manner, changing the negtive staircase into the positve one. Meanwhile, the 0 $Na^+-0\;Ca^{2+}$ KHB applicationinduced enhancement was strongly suppressed by caffeine (5 mM) pretreatment. Only dibucaine among the local anesthetics increased the basal tone during frequency reduciton. There were no differences in $^{45}Ca$ uptakes between 0.3 Hz and 3 Hz stimulation except at 1 min when it was significantly low at 0.3 Hz than 3 Hz, illustrating net $Ca^{2+}$ losses. Monensin pretreatment enhanced the rate of this $Ca^{2+}$ loss. Taken together, it is concluded that $Na^+-Ca^{2+}$ exchange extrudes more SR released $Ca^{2+}$ out of the cell in proportion to the frequency, resulting in the negative rate staircase in the rat LA.

  • PDF