• Title/Summary/Keyword: Excess loss

Search Result 263, Processing Time 0.029 seconds

Risk Assessment for Metalworking Fluids and Respiratory Outcomes

  • Park, Robert M.
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.428-436
    • /
    • 2019
  • Background: Metalworking fluids (MWFs) are mixtures with inhalation exposures as mists, dusts, and vapors, and dermal exposure in the dispersed and bulk liquid phase. A quantitative risk assessment was performed for exposure to MWF and respiratory disease. Methods: Risks associated with MWF were derived from published studies and NIOSH Health Hazard Evaluations, and lifetime risks were calculated. The outcomes analyzed included adult onset asthma, hypersensitivity pneumonitis, pulmonary function impairment, and reported symptoms. Incidence rates were compiled or estimated, and annual proportional loss of respiratory capacity was derived from cross-sectional assessments. Results: A strong healthy worker survivor effect was present. New-onset asthma and hypersensitivity pneumonitis, at 0.1 mg/㎥ MWF under continuous outbreak conditions, had a lifetime risk of 45%; if the associated microbiological conditions occur with only 5% prevalence, then the lifetime risk would be about 3%. At 0.1 mg/㎥, the estimate of excess lifetime risk of attributable pulmonary impairment was 0.25%, which may have been underestimated by a factor of 5 or more by a strong healthy worker survivor effect. The symptom prevalence associated with respiratory impairment at 0.1 mg/㎥ MWF was estimated to be 5% (published studies) and 21% (Health Hazard Evaluations). Conclusion: Significant risks of impairment and chronic disease occurred at 0.1 mg/㎥ for MWFs in use mostly before 2000. Evolving MWFs contain new ingredients with uncharacterized long-term hazards.

Dielectric and Electric Properties of Nb Doped PZT Thin Films by Sol-gel Technique (솔-젤법으로 제조한 PZT 박막의 Nb 첨가에 따른 유전 및 전기적 특성)

  • 김창욱;김병호
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.10
    • /
    • pp.1101-1108
    • /
    • 1996
  • No-doped PZT thin films have been fabricated on Pt/Ti/SiO2/Si substrate using Sol-Gel technique. A fast annealing metho (three times of intermediate and final annealing) was used for the preparation of multi-coated 1800$\AA$ thick Nb-doped PZT thin films. As Nb doping percent was increased leakage current was lowered approximately 2 order but dielectic properties were degraded due to the appearance of pyrochlore phase and domain pinning. Futhermore the increase of the final annealing temperature up to 74$0^{\circ}C$lowered the pyrochlore phase content resulting in enhancing the dielectric properties of the Nb doped films. The 3%-Nb doped PZT thin films with 5% excess Pb showed a capacitance density of 24.04 fF/${\mu}{\textrm}{m}$2 a dielectric loss of 0.13 a switchable polarization of 15.84 $\mu$C/cm2 and a coercive field of 32.7 kV/cm respectively. The leakage current density of the film was as low as 1.47$\times$10-7 A/cm2 at the applied voltage of 1.5 V.

  • PDF

Polyacrylamide Gel Immobilization of Porcine Liver Esterase for the Enantioselective Production of Levofloxacin

  • Lee, Sang-Yoon;Min, Byung-Hyuk;Song, Seong-Won;Oh, Sun-Young;Lim, Sang-Min;Kim, Sang-Lin;Kim, Dong-Il
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.3
    • /
    • pp.179-182
    • /
    • 2001
  • Porcine liver esterase was immobilized in polyacrylamide gel for the enantioselective production of levofloxacin from ofloxacin butyl ester. The initial activity of immobilized esterase was found to be significantly affected by the polyacrylamide gel composition. The optimum concentrations of monomer and crosslinker were determined to be 20% and 8.3%, respectively. The activity of immobilized esterase was 55.4% compared to a free enzyme. Enantiomeric excess was maintained at 60%, almost the same level as that of free enzyme. In addition, the immobilized esterase could be used repeatedly up to 10 times without experiencing any severe loss of activity and enantioselectivity.

  • PDF

COMPOSITION OF SUPERCONDUCTING YBCO THIN FILMS WITH RF REACTIVE SPUTTERING CONDITIONS

  • Kim, H.H.;Kim, S.;Shin, S.H.;Park, J.I.;Park, K.J.
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.829-833
    • /
    • 1996
  • Superconducting YBaCuO thin films were deposited on MgO (100) single crystal substrate by rf reactive sputtering method. Sputtering target was prepared by mixing the original powders of $Y_2O_3$, $BaCO_3$, and CuO at $830^{\circ}C$, and its composition was $YBa_2Cu_{3.3}O_x$ adding the excess CuO to compensate for the loss of Cu in the deposition process. The sputtering conditions for a high quality of YBCO thin film were: substrate temperature of 13$0^{\circ}C$; gas pressure of 10 mTorr; gas mixture ($O_2$: Ar =10: 90); distance of 2.5 inch; and rf power density of 4.87 W /$\textrm{cm}^2$. The deposition rate was 2.4~2.6 nm/min. From the RBS results, it was found that Cu and Ba contents in thin films decreased with the increase of substrate temperature. The increase of gas pressure resulted in significant deficiency of Ba elements.

  • PDF

Development of Biological Filtration Process for Effective Nitrogen Removal and its Control strategies in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거를 위한 운전제어법 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.230-237
    • /
    • 2006
  • The operational parameters and control strategies of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. Methanol addition was controlled based on the COD/N ratio or McCarty's equation. Constant COD/N ratio control results in excess addition under large diurnal fluctuation of $NOx^--N$, and McCarty's equation can be used to add appropriate amount of methanol. Control of methanol addition by on-line nitrate measurement, control of aeration by on-line DO measurement, and control of backwashing by head loss measurement are successfully operated. These results proved that this process prove the easy-maintenance and cost-effectively treatment is attainable.

Evaluation of the Pilot Village Project of Environment-Friendly Agriculture for a Rice Farming (친환경농업 시범마을 조성사업의 성과분석)

  • Kang, Choong-Kwan;Jung, Man-Chul
    • Korean Journal of Organic Agriculture
    • /
    • v.12 no.2
    • /
    • pp.121-134
    • /
    • 2004
  • Crop inputs in excess of the yield potential of the soil type reduce profitability and increase pollution problems from leaching and runoff. Inaccurate fertilizer and pesticide application can also result in profit loss. Current farming practices plan only for the dominate soil in the field. A government-supported program titled "Pilot village project for the environment-friendly agriculture" was proceeded from 1999 to 2001 to tackle the problems with which our agriculture is faced by introducing IPM, INM and others. The objective of this study is to consider the potential input savings of agricultural chemicals and economic feasibility of the project compared with the conventional farming. The results of the analysis indicate the followings: (1) organic or no-pesticide farming size was increased from 9% in 1999 to 20% in 2001 ; (2) crop yield was a link bit lower than that of the conventional farming, but the sal6 price, gross income and income of the pilot village were 6%, 10% and 9% higher than that of the conventional farming, respectively; and (3) fertilizer and pesticide use also showed decreasing trend gradually.

  • PDF

Effect of a Multi Air-staged Burner on NOx Formation and Heat Transfer in Furnace Adopted the Reburning Process (재연소 과정을 적용한 연소로에서 공기 다단 연소기의 NOx 발생 및 열전달에 대한 효과)

  • Kim, Hyuk-Su;Baek, Seung-Wook;Lee, Chang-Yeop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.842-849
    • /
    • 2006
  • An experimental study has been conducted to investigate the effects of a multi air-staged burner on NOx formation and heat transfer in a 15kW large-scale laboratory furnace adopted the reburning process. The reburn fuel as well as burnout air was injected from each nozzle attached at the wall of the cylindrical furnace. Fuel in both main burner and reburn nozzle was LPG (Liquefied Petroleum Gas). The paper reports the influences on NOx reduction of reburn fuel fraction in reburning zone. Temperature distribution inside the overall region as well as total heat flux at the wall of the furnace has been measured to examine the heat transfer characteristics due to the reburning process. For comparison, the reburning effects were examined for a combustor with two types of burner; a regular single staged burner and a multi-air staged burner. A gas analysis was also performed to evaluate an appropriate condition for NOx emission in a primary zone for the excess air ratio of 1.1. As a result, combustion efficiency expected to become more efficient due to the reduction of heat loss in burnout zone decrease when multi air-staged burner in furnace adopted reburning technology was used.

Development of Flood Analysis Module for the Implementation of a Web-Based Flood Management System (웹기반 홍수관리시스템 구현을 위한 홍수분석모듈개발)

  • Jung, In Kyun;Park, Jong Yoon;Kim, Seong Joon;Jang, Cheol Hee
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.103-111
    • /
    • 2014
  • This study was to develop the flood analysis module (FAM) for implementation of a web-based real-time agricultural flood management system. The FAM was developed to apply for an individual watershed, including agricultural reservoir. This module calculates the flood inflow hydrograph to the reservoir using effective rainfall by NRCS-CN method and unit hydrograph calculated by Clark, SCS, and Nakayasu synthetic unit hydrograph methods, and then perform the reservoir routing by modified Puls method. It was programmed to consider the automatic reservoir operation method (AutoROM) based on flood control water level of reservoir. For a $15.7km^2$ Gyeryong watershed including $472{\times}10^4m^3$ agricultural reservoir, rainfall loss, rainfall excess, peak inflow, total inflow, maximum discharge, and maximum water level for each duration time were compared between the FAM and HEC-HMS (applied SCS and Clark unit hydrograph methods). The FAM results showed entirely consistent for all components with simulated results by HEC-HMS. It means that the applied methods to the FAM were implemented properly.

The Effect of Non-stoichiometry on the Microwave Absobing Properties of Ni-Zn Ferrites. (비화학양론적 조성이 니켈-아연 페라이트의 전파흡수특성에 미치는 영향)

  • 조성백;오재희
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 1995
  • The systematic variation of complex permeability and complex permittivity and their relationship with micro-wave absorbing properties are investigated in sintered Ni-Zn ferrites of non-stoichiometric composition. The specirrens of ${(Ni_{0.5}Zn_{0.5}O)}_{1-x}(Fe_{2}O_{3})_{1+x}$ spinels were prepared by a conventional ceramic processing technique. In the present study. complex permeability and permittivity can be controlled by the variation of ${\alpha}-Fe_{2}O_{3}$ contents in the spinel lattice. The primary effect of the excess ${\alpha}-Fe_{2}O_{3}$ is to increase the dielectric constant. while the notable decrease of magnetic loss is observed in the iron-deficient ferrites. The results suggest that the matching fre-queocyand matching thickness could be controlled by the variation of ${\alpha}-Fe_{2}O_{3}$ contents in the Ni-Zn ferrite.

  • PDF

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.