• 제목/요약/키워드: Exact test

검색결과 1,479건 처리시간 0.031초

요중(尿中) B형(型) 간염항원(肝炎抗原) 발현(發現)의 의의(意義)에 관(關)한 연구(硏究) (The Study on the Prevalence and Significance of Urinary HBsAg. Detection)

  • 한진석;표희정;신영태;박정식;김성권;최강원;이정상;이문호
    • 대한핵의학회지
    • /
    • 제15권1호
    • /
    • pp.27-32
    • /
    • 1981
  • HBsAg. was identified in the urine of the patients positive for serum HBsAg. by Tripatzis in 1970. In 1977, Hourani et al reported the incidence of HBsAg. in urine was about 52% in the patients positive for serum HBsAg. with hemodialysis treatment due to chronic renal failure. A series of studies on the HBsAg. in urine has revealed the urine of the patients positive for serum HBsAg. to be important source of infection. But there's much room to debate on the relationship of HBsAg. in urine with infectivity and the exact mechanism of urinary emergence of HBsAg. The authors detected HBsAg. in serum and urine by employing sandwitch solid-phase rad ioimmunoassay, and performed urinalysis, liver function test and renal function evaluation. Percutanous liver and/or kidney biopsis were done. Among 38 renal disease patients, 9 cases (23.4%) were shown to be positive for serum HBsAg. and 5 cases (55.5%) among above 9 patients positive for urine HBsAg.. 56 cases (67.4%) of 83 liver disease patients revealed positive for serum HBsAg. but only 11 cases (13.2%) among the 56 cases positive fo urine HBsAg. All 10 renal and liver disease patients revealed positive serum HBsAg., and among the 9 cases (90%) positive for urine HBsAg.. In the 25 patients positive for urine HBsAg. all of 5 renal patients and 9 renal and liver patients had hematuria or/and proteinuria above 2 positive for albumin. But in the 11 liver patients 6 cases (55.1%) were normal findings. And there's no significant difference in cpm of urine HBsAg. between the patient positive for serum HBsAg. and negative, and in cpm of serum HBsAg. between liver and renal disease patients. But there's statistical significance in cm of urine HBsAg. between renal and liver diseases.

  • PDF

게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가 (The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan)

  • 이동훈;유희재;이종훈;정우영
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

원자층 증착법에 의한 TiO2, Al2O3, 및 TiO2-Al2O3 나노라미네이트 박막이 316L Stainless Steel의 부식특성에 미치는 영향 (Corrosion Properties of Atomic Layer Deposited TiO2, Al2O3 and TiO2-Al2O3 Nanolaminated Film Coated 316L Stainless Steel)

  • 이우재;만지흠;김다영;장경수;최현진;최우창;권세훈
    • 한국표면공학회지
    • /
    • 제50권1호
    • /
    • pp.35-41
    • /
    • 2017
  • $TiO_2$, $Al_2O_3$, and $TiO_2-Al_2O_3$ nanolaminated films were grown by atomic layer deposition (ALD) on the 316L stainless steel (SS316L) substrates at a temperature of $150^{\circ}C$. The growth kinetics of $ALD-TiO_2$ and $Al_2O_3$ thin films were systematically investigated in order to precisely control the thickness of each layers in the $TiO_2-Al_2O_3$ nanolaminated films using a high-resolution transmission electron microscopy. And, the exact deposition rates of $ALD-TiO_2$ on $Al_2O_3$ surface and $ALD-Al_2O_3$ on $TiO_2$ surface were revealed to be 0.0284 nm/cycle and 0.11 nm/cycle, respectively. At given growth conditions, the microstructures of $TiO_2$, $Al_2O_3$ and $TiO_2-Al_2O_3$ nanolaminated films were amorphous. The potentiodynamic polarization test revealed that the $TiO_2-Al_2O_3$ nanolaminated film coated SS316L had a best corrosion resistance, although all ALDcoated SS316L exhibited a clear improvement of the corrosion resistance compared with a bare SS316L.

정량적 전자토모그래피를 위한 Beer's law의 실험적 검증 (Experimental Examination of the Beer's law for Quantitative Electron Tomography)

  • 김진규;송경;이수정;주형태;김윤중
    • Applied Microscopy
    • /
    • 제40권2호
    • /
    • pp.117-123
    • /
    • 2010
  • 본 연구에서는 의생물 시료에 대해 정량적 전자토모그래피의 기본 전제 조건인 Beer's law를 실험적으로 검증하였다. 시료는 의생물 시료와 비슷한 흡수계수를 갖는 카본 지지막과 latex sphere의 시료를 선택하였으며, 연속적으로 기울어진 TEM 이미지를 획득하였다. 우선, 전자토모그래피를 수행하여 카본 지지막과 latex sphere의 기본 상태를 파악하였다. Beer's law의 검증을 위해 각각의 물질에 대해 경사각 기울기에 따라 입사빔의 강도와 투과빔의 강도의 변화를 측정하여 회귀분석을 수행하였으며, 그 결과 RMS값 0.976의 범위에서 선형적인 관계를 확인할 수 있었다. 또한 Beer's law를 이용하여 카본 지지막과 latex sphere에 대한 각각의 상대적인 흡수계수를 구했으며, 그 값은 대략 1.71(5)/${\mu}m$과 2.67(6)/${\mu}m$으로 경사각 기울기에 대하여 일정하게 유지됨을 알 수 있었다. 따라서, 정밀한 실험조건에서 입사빔의 정보를 유추할 수 있다면 의생물 시료에 대해 엄밀한 Beer's law가 성립하는 정량적인 전자토모그래피가 수행될 수 있을 것으로 기대된다.

중학교 학생의 증명 능력 분석 (Analysis on Students' Abilities of Proof in Middle School)

  • 서동엽
    • 대한수학교육학회지:수학교육학연구
    • /
    • 제9권1호
    • /
    • pp.183-203
    • /
    • 1999
  • In this study, we analysed the constituents of proof and examined into the reasons why the students have trouble in learning the proof, and proposed directions for improving the teaming and teaching of proof. Through the reviews of the related literatures and the analyses of textbooks, the constituents of proof in the level of middle grades in our country are divided into two major categories 'Constituents related to the construction of reasoning' and 'Constituents related to the meaning of proof. 'The former includes the inference rules(simplification, conjunction, modus ponens, and hypothetical syllogism), symbolization, distinguishing between definition and property, use of the appropriate diagrams, application of the basic principles, variety and completeness in checking, reading and using the basic components of geometric figures to prove, translating symbols into literary compositions, disproof using counter example, and proof of equations. The latter includes the inferences, implication, separation of assumption and conclusion, distinguishing implication from equivalence, a theorem has no exceptions, necessity for proof of obvious propositions, and generality of proof. The results from three types of examinations; analysis of the textbooks, interview, writing test, are summarized as following. The hypothetical syllogism that builds the main structure of proofs is not taught in middle grades explicitly, so students have more difficulty in understanding other types of syllogisms than the AAA type of categorical syllogisms. Most of students do not distinguish definition from property well, so they find difficulty in symbolizing, separating assumption from conclusion, or use of the appropriate diagrams. The basic symbols and principles are taught in the first year of the middle school and students use them in proving theorems after about one year. That could be a cause that the students do not allow the exact names of the principles and can not apply correct principles. Textbooks do not describe clearly about counter example, but they contain some problems to solve only by using counter examples. Students have thought that one counter example is sufficient to disprove a false proposition, but in fact, they do not prefer to use it. Textbooks contain some problems to prove equations, A=B. Proving those equations, however, students do not perceive that writing equation A=B, the conclusion of the proof, in the first line and deforming the both sides of it are incorrect. Furthermore, students prefer it to developing A to B. Most of constituents related to the meaning of proof are mentioned very simply or never in textbooks, so many students do not know them. Especially, they accept the result of experiments or measurements as proof and prefer them to logical proof stated in textbooks.

  • PDF

다양한 거칠기의 알루미늄 옥사이드(Al2O3) 연마석을 이용한 치주기구 날 세우기의 효율성 비교 (Comparing the efficiency of periodontal instrument sharpening using aluminum oxide stones with different levels of roughness)

  • Kim, Yong-Gun
    • 구강회복응용과학지
    • /
    • 제30권2호
    • /
    • pp.131-137
    • /
    • 2014
  • 목적: 이 연구는 다양한 거칠기를 가진 알루미늄 옥사이드 연마석으로 치주기구 날 세우기를 시행시 연마석의 거칠기에 따른 치주기구 날 세우기의 효율성 및 마모도를 비교 평가하였다. 연구 재료 및 방법: 30개의 No. 9 - 10 그레이시 큐렛이 사용되었고, 모든 큐렛은 치석제거술 및 치근활택술을 시행함으로써 날을 무디게 만들고 3가지 그룹(240, 600, 800 grit)으로 임의로 나누었다. 치주기구의 예민도는 연마석을 최대 20회 기구에 적용한 후 평가되었고, 마모도는 최대 80회 후 기구 날의 끝 1 mm와 2 mm에서 기구 날의 폭으로 평가되었다. 결과: 치주기구 예민도는 5회와 10회 상하 운동시 240 grit에서 유의하게 높게 나타났으며(P < 0.001), 15회, 20회에서는 유의한 차이는 없었다(P > 0.05). 마모도는 240 grit의 경우 600 grit과 800 grit에 비해 약간 높게 나타났지만 통계적 유의성은 없었다. 결론: 알루미늄 옥사이드 연마석의 입자가 클수록 치주기구 날 세우기의 효율성은 증가하였다. 하지만 기구의 마모에 유의해야 한다.

영상처리 기법을 이용한 샥-하트만 파면 센서의 측정범위 확장에 대한 연구 (A Study on the Dynamic Range Expansion of the Shack-Hartmann Wavefront Sensor using Image Processing)

  • 김민석;김지연;엄태경;윤성기;이준호
    • 한국광학회지
    • /
    • 제18권6호
    • /
    • pp.375-382
    • /
    • 2007
  • 샥-하트만 센서는 렌즐릿 배열을 이용하여 파면의 국부적인 기지를 계산하고 이로부터 파면의 왜곡된 정도를 측정하는 파면측정 센서이다. 일반적으로 하나의 점영상에 대한 중심점을 추출하여 기준 점영상의 중심점에 대한 상대적 이동량을 통해 파면의 국부 기울기를 계산, 전체 파면을 복원하는 원리이다. 따라서 하나의 점영상에 대한 정확한 중심점의 추출을 위하여 해당하는 하부개구 내에 점영상이 존재하여야 한다. 하지만 큰 기울기의 파면이 샥-하트만 센서에 입사하게 되면 측정범위를 벗어나게 되어 일반적인 방법으로는 파면의 국부적인 기울기를 계산할 수 없게 되는 문제점이 있다. 이를 해결하기 위해 특정 측정시스템에만 국한된 알고리즘이 아닌 모든 파면에 대해 측정 가능하면서도 추가적인 장비 없이 일반적인 샥-하트만 파면 센서가 지니고 있는 측정범위의 한계를 극복할 수 있는 알고리즘이 필요하다. 본 연구에서는 영상처리 기법을 이용하여 각 점영상에 대한 유동적인 탐색영역을 설정하고 이러한 탐색영역 내에서 중심점을 추출하는 방법을 제안하였다. 또 점영상 대응법을 적용하여 측정 점영상과 기준 점영상을 일대일 대응시킴으로써 전체 측정파면을 복원할 수 있는 알고리즘을 제안함으로써 측정범위에 제한 없이 파면왜곡을 측정할 수 있는 측정방법을 제시하였다. 이렇게 제안된 알고리즘을 샥-하트만 파면 센서 시스템을 이용한 초점벗어남 측정실험을 통하여 검증하였다.

어닐링 온도 변화가 Al/연강 클래드재의 계면 특성에 미치는 영향 (Effects of Annealing Temperature on Interface Properties for Al/Mild Steel Clad Materials)

  • 정은욱;김희봉;김동용;김민중;조영래
    • 한국재료학회지
    • /
    • 제22권11호
    • /
    • pp.591-597
    • /
    • 2012
  • For heat exchanger applications, 2-ply clad materials were fabricated by rolling of aluminum (Al) and mild steel sheets. Effects of annealing temperature on interface properties, especially on inter-layer formation and softening of strain hardened mild-steel, for Al/mild steel clad materials, were investigated. To obtain optimum annealing conditions for the Al/mild steel clad materials, annealing temperature was varied from room temperature to $600^{\circ}C$. At the annealing temperature about $450^{\circ}C$, an inter-layer was formed in an island-shape at the interface of the Al/mild steel clad materials; this island expanded along the interface at higher temperature. By analyzing the X-ray diffraction (XRD) peaks and the energy dispersive X-ray spectroscopy (EDX) results, it was determined that the exact chemical stoichiometry for the inter-layer was that of $Fe_2Al_5$. In some samples, an X-layer was formed between the Al and the inter-layer of $Fe_2Al_5$ at high annealing temperature of around $550^{\circ}C$. The existence of an X-layer enhanced the growth of the inter-layer, which resulted in the delamination of the Al/mild-steel clad materials. Hardness tests were also performed to examine the influence of the annealing temperature on the cold deformability, which is a very important property for the deep drawing process of clad materials. The hardness value of mild steel gradually decreased with increasing annealing temperature. Especially, the value of hardness sharply decreased in the temperature range between $525^{\circ}C$ and $550^{\circ}C$. From these results, we can conclude that the optimum annealing temperature is around $550^{\circ}C$ under condition of there being no X-layer creation.

가압 경수로의 냉각재 계통 열팽창 거동에 관한 연구 (A Study On The Thermal Movement Of The Reactor Coolant System For PWR)

  • Yoon, Ki-Seok;Park, Taek sang;Kim, Tae-Wan;Jeon, Jang-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.393-402
    • /
    • 1995
  • 원자로냉각재계통의 설계를 위한 구조해석 분야에는 원자로의 정상운전 과정에서 발생하는 유체의 온도와 압력의 변화에 의해 냉각재계통에 발생하는 정적하중해석, 지진과 가상적인 분지관 파단사고에 의해 냉각재계통에 발생하는 동적하중해석분야로 구분할 수 있다. 원자로냉가재계통의 구조해석은 원자력발전소의 안전성 화보 측면을 중시하여 해석시 충분한 여유도를 고려한 보수적인 해석 방법을 원용한다. 지진이나 가상적인 분지관 파단사고에 의한 냉각재계통의 구조해석은 사고시 냉각재계통의 안전성을 유지하는 방어적인 개념으로서 기기의 건전성을 확보하기 위하여 충분한 보수성과 안전여유가 해석시 고려된다 정상운전에 의해 냉각재계통에 발생하는 하중은 원자력 발전소의 상존하는 하중의 개념으로서 냉각재계통의 기본 설계 하중으로 인식된다. 특히 고온 고압의 유체로 인하여 발생하는 냉각재 계통의 열팽창 현상은, 정상운전 하중으로 인하여 나타나는 전형적인 거동으로서, 냉각재계통 구조해석 결과읜 중요한 지표로서 인식된다. 따라서 냉각재계통의 열팽창 현상을 정확히 예측하는 것은 원자로 냉각재계통 구조해석의 가장 중요한 목표중의 하나이다. 본 연구에서는 정상운전 하중에 의한 원자로 냉가재계통의 열팽창 거동을 해석하기 위한 냉각재계통의 모델링 방법과 해석 방법을 제시하였다. 해석 결과의 타당성을 검토하기 위하여 최근 건설 완료 단계에 돌입한 표준형 1000 MWe 급 가압경수로(Pn)의 고온기능시험 (Hot Function Test)과정에서 실측한 자료를 근거로 하여 원자로냉각재계통의 열팽창 거동 해석의 타당성을 입증코자 하였다.

  • PDF

X-ray 이미지를 활용한 증강현실 기반 심전도 측정시스템 개발 (Using the X-ray Image, Augmented Reality based electrocardiogram measurement system Development)

  • 이광인;장진수;이태노
    • 디지털융복합연구
    • /
    • 제14권9호
    • /
    • pp.331-339
    • /
    • 2016
  • 경제성장과 함께 생활습관 변화로 인한 만성질환이 지속적으로 증가하고 있다. 그 중 심뇌혈관질환은 사망원인의 약 20%를 차지하는 우리나라의 주요 사망원인이다. 심장의 이상을 측정하는 검사는 심전도검사로, 심장의 리듬을 전기적으로 측정하여 평가하는 방법이다. 심전도 검사에서 가장 영향을 미치는 것은 전극의 부착 위치인데, 간호사를 대상으로 연구한 결과에 따르면 모두 정확하게 부착한 것은 2.6%로 나타났다. 따라서 본 연구는 이러한 문제를 해결하기 위해 프로젝션 기반의 증강현실 기술을 사용하여 환자 본인의 Chest X-ray 사진을 흉부에 중첩시켜 투영시킴으로써 정확한 전극 부착위치를 쉽게 알 수 있는 시스템을 개발하였다. 기존의 방법으로 측정한 결과와 개발한 시스템으로 측정한 결과를 비교하였더니 2.6cm의 오차를 보였다. 그에 따른 심전도 결과에서도 V1, V2, V3위치에서 눈에 띄는 파형의 차이가 있었다. 본 시스템으로 정확하게 측정된 심전도는 의료진들의 환자관리 및 임상적 의사결정에 크게 도움이 될 것이다.