• 제목/요약/키워드: Evoked potentials

검색결과 187건 처리시간 0.03초

경막혈종 및 뇌내압 증가에 따른 청각 유발전위의 분석 (EVALUATION OF AUDITORY EVOKED POTENTIALS IN WHITE NEW ZEALAND RABBITS WITH SIMULATED SUBDURAL HEMATOMA AND INCREASED INTRACRANIAL PRESSURE)

  • 임재중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.171-174
    • /
    • 1992
  • Development of a noninvasive intensive care system calls for the use of evoked potentials (EPs), as a means of diagnosing traumatic head-injured patients. The experiment entails surgically plating two subarachnoid bolts and a subdural balloon through the skull to simulate a subdural hematoma. Using various levels of intracranial pressure (ICP) and/or different sizes of balloons, auditory evoked potentials (AEPs) were recorded from a rabbit. Six positive peat latencies ($P_1-P_6$) and five negative peak latencies ($N_1-N_5$) were extracted from an averaged AEP waveform. Multiple regression analyses were performed for determining a relationship between the ICP and AEP peak latencies. The results indicate that a major correlation of changes on AEP peak latencies is due to mechanical forcer of a mass (inflated balloon simulating a hematoma) in the distortion of the brain matter rather than increased ICP.

  • PDF

Usefulness of Motor-Evoked Potentials Monitoring for Neurosurgical Treatment of an Unusual Distal Anterior Choroidal Artery Aneurysm

  • Champeaux, Charles;Jecko, Vincent;Eimer, Sandrine;Penchet, Guillaume
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권4호
    • /
    • pp.414-419
    • /
    • 2016
  • A 35 years old woman presented with an acute meningeal syndrome following an intra ventricular haemorrhage without subarachnoid haemorrhage. The angiography demonstrated a 6 mm partially thrombosed saccular aneurysm at the plexal point of the right anterior choroidal artery (AChoA). It was surgically approached inside the ventricle through a trans-temporal corticotomy. The aneurysm was excised after distal exclusion of the feeding artery under motor-evoked potentials monitoring. Of the 19 cases of distal AChoA aneurysm neurosurgical treatment, this is the only one performed under electrophysiology monitoring, a simple and safe method to detect and prevent motor tract ischemia. We discuss this rare case, along with a comprehensible review of the literature of the previous surgical cases of distal AChoA aneurysms.

Intraoperative monitoring of somatosensory and visual evoked potentials for detecting posterior cerebral artery infarction during anteromesial temporal resection

  • Seo, Suyeon;Kim, Dong Jun;Lee, Chae Young
    • Annals of Clinical Neurophysiology
    • /
    • 제22권2호
    • /
    • pp.104-108
    • /
    • 2020
  • We performed intraoperative neurophysiological monitoring (INM) during anteromesial temporal resection (AMTR) in a patient with lesional temporal lobe epilepsy. INM revealed a sudden decrease in N20 waves in somatosensory evoked potentials (SSEPs) and poor P100 waves in visual evoked potentials (VEPs). These changes developed after applying electrocoagulation in the right mesial temporal areas. Postoperative brain magnetic resonance imaging demonstrated right thalamic and medial occipital infarctions. SSEPs and VEPs monitoring can be useful for detecting posterior cerebral artery infarction in AMTR.

Precise spectral analysis using a multiple band-pass filter for flash-visual evoked potentials

  • Asano, Fumitaka;Shimoyama, Ichiro;Kasagi, Yasufumi;Lopez, Alex
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2002년도 춘계학술대회 논문집
    • /
    • pp.44-50
    • /
    • 2002
  • The fast Fourier transform (FFT) is a good method to estimate spectral density, but the frequency resolution is limited to the sampling window, and thus the precise characteristics of the spectral density for short signals are not clear. To solve the limitation, a multiple band-pass filter was introduced to estimate the precise time course of the spectral density for flash visual evoked potentials (VEPs). Signals were recorded during -200 and 600 ms using balanced noncephalic electrodes, and sampled at 1 K Hz in 12 bits. With 1 Hz and 10 ms resolutions, spectral density was estimated between 10 and 100 Hz. Background powers at the alpha-and beta-bands were high over the posterior scalp, and powers around 200ms were evoked at the same bands over the same region, corresponding to P110 and N165 of VEPs. normalized's spectral density showed evoked powers around 200 ms and suppressed powers following the evoked powers over the posterior scalp. The evoked powers above the 20Hz band were not statistically significant. However, the gamma band was significantly evoked intra-individually; details in the gamma bands were varied among the subjects. Details of spectral density were complicated even for a simple task such as watching flashes; both synchronization and desynchronization occurred with different distributions and different time courses.

  • PDF

성격유형과 유발전위 연구 (A Study of Personality type & Evoked Potentials)

  • 장석우
    • 감성과학
    • /
    • 제14권1호
    • /
    • pp.137-146
    • /
    • 2011
  • 최근 뇌 과학의 발달로 심리학의 다양한 이슈들을 뇌과학으로 설명하려는 노력들이 많이 시도되고 있다. 본 연구에서는 성격유형을 뇌과학으로 설명될 수 있는지 시도해보고자 하였다. 성격유형검사 중 MBTI를 토대로 하여 10대 청소년 190명에게 성격유형별 레이븐의 유사도형 구분과제를 실시하였다. 이 때 피험자에게 유발전위 뇌파를 검출하고 통계 분석하여 성격유형별간에 집중력의 차이가 있는지를 알아보았다. 또한 뇌파의 주파수별 분류를 통하여 어느 주파수대가 성격유형별간의 차이가 보이는지 알아보았다. 결론적으로 외향성과 내향성은 유사도형 구분과제를 수행하는 동안 두 집단 간의 집중력 차이가 나타났으며 M-Beta파와 Gamma파 및 H-Beta파에서 두 집단 간 차이가 나타났으며 감각형과 직관형은 쉬운 난이도 과제와 중간 난이도 과제에서 두 집단 간 집중력의 차이가 나타나는 경향성이 보였으며 주파수별 분류에서는 두 집단 간의 차이가 없었다. 사고형과 감정형은 과제를 수행하는 동안 두 집단 간 집중력의 차이가 나타났으며 뇌파 주파수별 분류에서는 H-Beta파에서만 차이가 있었다. 판단형과 인식형은 모든 과제와 주파수별 분류에서도 두 집단 간 차이가 나타나지 않았다. 기존 성격유형과 뇌파연구가 외향성과 내향성에 집중되어 있고 다양한 유형별 연구가 미비하였다. 따라서 난이도가 상, 중, 하의 세 가지로 분류된 유사도형 구분과제를 수행하는 동안 유발전위 뇌파를 통해 뇌파를 분석한 것은 본 연구의 의의라 할 수 있다.

  • PDF

비침습적 뇌내압 측정 시스템의 개발을 위한 청각유발전위와 경막혈종간의 상관관계 분석에 관한 연구 (A Correlational Study between Auditory Evoked Potential and Subdural Hematoma for the Diveloprnent of a Noninvasive ICP Monitoring System)

  • 임재중
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.167-174
    • /
    • 1995
  • Development of a noninvasive intensive care system calls for the use of evoked potentials (EPs) as a means of diagnosing traumatic head-injured patients. The experiment entails surgically placing two subarachnoid bolts and a subdural balloon through the skull to simulate a subdural hematoma. Using various levels of intracranial pressure (ICP) and/or different sizes of balloons, auditory evoked potentials (AEPs) were recorded from a rabbit. Six positive peak latencies ($P_1 - P_6$) and five negative peak latencies ($N_l- N_5$) were extracted from an averaged AEP waveform. Multiple regression analyses were performed for determining. a relationship between the ICP and AEP peak latencies. The results indicate that a major correlation of ch, mges on AEP peak latencies is due to mechanical forces of a mass (inflated balloon simulating a hematoma) in the distortion of the brain matter rather than increased ICP itself.

  • PDF

백서 하치조 신경 손상에 따른 감각 유발전위와 체성감각 유발전위의 변화에 관한 연구 (CHANGES OF SENSORY AND SOMATOSENSORY EVOKED POTENTIALS FOLLOWING A NEEDLE INJURY ON THE INFERIOR ALVEOLAR NERVE IN RATS)

  • 우승철;김수남;이동근;천상우
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권4호
    • /
    • pp.652-672
    • /
    • 1996
  • Dysfunction of the inferior alveolar nerve may result from trauma, diseases or iatrogenic injury. The development and refinement of an objective method to evaluate this clinical problem is highly desirable and needed, especially concerning for an increasing medico-legal issue. Evoked potential techniques have attracted considerable attention as a means of assessing the function and integrity of nerve pathways. The purpose of this study was to characterize the Sensory Evoked Potentials(SEPs) and Somatosensory Evoked Potentials(SSEPs) elicited by electrical stimulation of mental nerve. SEPs and SSEPs were measured and analyzed statistically before and after needle injury on the inferior alveolar nerve of Sprague-Dawalye rats. Measuring SEPs was more sensitive in evaluation of the recovery of sensory function from inferior alveolar nerve injury then measuring SSEPs but we measured SSEPs in the hope of providing a safe, simple and objective test to check oral and facial sensibility, which is acceptable to the patient. We stimulated mental nerve after needle injury on the inferior alveolar nerve and SEPS on the level of mandibular foramen and SSEPs on the level of cerebral cortex were recorded. Threshold, amplitude, and latency of both of SEPs and SSEPs were analyzed. The results were as follows ; 1. Threshold of SEPs and SSEPs were $184{\pm}14{\mu}A$ and $164{\pm}14{\mu}A$ respectively. 2 SEPs were composed of 2 waves, i.e., N1 N2 in which N1 was conducted by II fibers and N2 was conducted by III fibers. 3. SSEPS were composed of 5 waves, of which N1 and N2 shower statistically significant changes(p<0.01, unpaired t-test). 4. SEPs and SSEPs were observed to be abolished immediately after local anesthesia and recovered 30 minutes later. 5. SEPs were abolished immediately after injury. N1 of SSEPs was abolished immediately and amplitued of N2 was decreased($20.7{\pm}12.2%$) immediately after 23G needle injury, but N3, N4 and N5 did not change significantly. Recovery of waveform delayed 30 minutes in SEPs and 45 minutes in SSEPs. 6. The degree of decrease in amplitude of SEPs and SSEPs, after 30G needle injury was smaller than those with 23G. SEPs recorded on the level of mandibular foramen were though to be reliable and useful in the assessment of the function of the inferior alveolar nerve after injury. Amplitude of SSEPs reflected the function and integrity of nerve and measuring them provided a safe, simple and abjective test to check oral and facial sensibility. These results suggest that measuring SEPs and SSEPs are meaningful methods for objective assessment in the diagnosis of nerve injury. N1 and N2 of SSEPs can be useful parameters for the evaluation of the nerve function following a needle injury.

  • PDF

A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials

  • Jin, Seung-Hyun;Chung, Chun Kee;Kim, Jeong Eun;Choi, Young Doo
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권6호
    • /
    • pp.455-462
    • /
    • 2014
  • Objective : To propose a new measure for effective monitoring of intraoperative somatosensory evoked potentials (SEP) and to validate the feasibility of this measure for evoked potentials (EP) and single trials with a retrospective data analysis study. Methods : The proposed new measure (hereafter, a slope-measure) was defined as the relative slope of the amplitude and latency at each EP peak compared to the baseline value, which is sensitive to the change in the amplitude and latency simultaneously. We used the slope-measure for EP and single trials and compared the significant change detection time with that of the conventional peak-to-peak method. When applied to single trials, each single trial signal was processed with optimal filters before using the slope-measure. In this retrospective data analysis, 7 patients who underwent cerebral aneurysm clipping surgery for unruptured aneurysm middle cerebral artery (MCA) bifurcation were included. Results : We found that this simple slope-measure has a detection time that is as early or earlier than that of the conventional method; furthermore, using the slope-measure in optimally filtered single trials provides warning signs earlier than that of the conventional method during MCA clipping surgery. Conclusion : Our results have confirmed the feasibility of the slope-measure for intraoperative SEP monitoring. This is a novel study that provides a useful measure for either EP or single trials in intraoperative SEP monitoring.

EEG Current Source Imaging using VEP Data Recorded inside a 3.0T MRI Magnet

  • Han Jae Y.;Choi Young H.;Im Chang H.;Kim Tae-S.;Lee Soo Y.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권2호
    • /
    • pp.95-99
    • /
    • 2005
  • We have performed EEG current source imaging on the cortical surface using visual evoked potentials (VEPs) recorded inside a 3.0 T MRI magnet. In order to remove ballistocardiogram (BCG) artifacts in the VEPs, an improved BCG template subtraction technique is devised. Using the cortically constrained current source imaging technique and pattern-reversal visual stimulations, we have obtained current source maps from 10 subjects. To validate the EEG current source imaging inside the magnet, we have compared the current source maps to the ones obtained outside the magnet. The experimental results demonstrate that there is a strong correspondence between the current source maps, proving that current source imaging is feasible with the evoked potentials recorded inside a 3.0 T MRI magnet.

상관계수와 뉴럴 네트워크를 이용한 뇌 유발 전위의 분류 (CLASSIFICATION OF BRAIN EVOKED POTENTIAL USING CORRELATION COEFFICIENTS AND NEURAL NETWORK)

  • 지영준;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.189-192
    • /
    • 1995
  • In Visually Evoked Potentials(VEP) or Auditory Evoked Potentials(AEP), the components by the stimulation and the components which are irrelevant to the stimulation(noise or nonstationary spontaneous EEG) are mixed together. So one should average hundreds of EP waves to extract the components by the stimulation only. In this study, we have classified EP's, which are the responses of the different stimulations and different states of subjects. To classify the EP waves, the cross-correlation coefficients and neural network method(error back propagation) are used and compared.

  • PDF