Perovskite Solar Cells through Application of Hole Transporting Layers based on Vacuum Thermal Evaporation (진공 열 증착 기반의 정공수송층 적용을 통한 페로브스카이트 태양전지)

  • Kim, Hye Seung;Song, Myoung Hoon
    • Current Photovoltaic Research
    • /
    • v.10 no.1
    • /
    • pp.23-27
    • /
    • 2022
  • In this study, we investigate organic-inorganic halide perovskite solar cells with a vacuum thermal evaporated hole transporting layer (NPB/MoO3-x). By replacing solution process based Spiro-MeOTAD with vacuum thermal evaporation based NPB/MoO3-x, a thin hole transporting layer was implemented. In addition, parasitic absorption that may occur during the doping process was eliminated by excluding solution process doping. In a solar cell with a thin vacuum thermal evaporated hole transporting layer, the short-circuit current density (Jsc) increased to 23.93 mA/cm2, resulting in the highest power converstion efficiency (PCE) at 18.76%. Considering these results, it is essential to control the thickness of hole transporting layer located at the top in solar cell configuration.

Performance Characteristics of a Mixed Refrigerant OTEC Power Cycle Using Hot Waste Water (온배수를 이용한 혼합냉매용 해양온도차 발전 사이클의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Heo, Jeong-Ho;Ye, Byoung-Hyo;Kim, Hyun-Ju;Lee, Ho-Saeng
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.102-107
    • /
    • 2013
  • In this paper, the performance analysis for evaporation capacity, total work and efficiency of the ocean thermal energy conversion(OTEC) power system using mixed refrigerant(R32,R152a) is conducted to find the effect of hot wasted water on OTEC power system. The system in this study is applied with two stage turbine, regenerator, cooler and separator on Organic Rankine Cycle. The commercial program HYSYS is used for the performance analysis. The main results were summarized as follows : The efficiency of the OTEC power cycle has a largely effect on the evaporation capacity and total work. As increasing temperature of heat source water, evaporator's capacity is decreased but total work increase. Otherwise, using hot wasted water bring effects not only increasing system efficiency but also declining evaporator's capacity. Thus With a thorough grasp of these effect, it is necessary to find way to use hot wasted water emitted by power plant and so on.

The fabrication of ITO/p-InP solar cells (ITO/p-InP 태양전지 제작)

  • 맹경호;김선태;송복신;문동찬
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.243-251
    • /
    • 1994
  • ITO(Indium Tin Oxide) film with thickness of 1500.angs. was prepared by an e-beam evaporator onto a glass and a p-type InP wafer (100) LEC grown Zn-doped p=2.3*10$\^$16/cm$\^$-3/), in which the components of ITO used for evaporation source were hot pressed pellets 1 mole% ln$\_$2/O$\_$3/+9 mole% SnO$\_$2/, and evaporated in O$\_$2/ ambient. The optimum conditions to preparation of ITO thin film were the substrate temperature of 350.deg. C, the injected oxygen pressure of 2*10$\^$-4/ torr, and the evaporation speed of 0.2-0.3.angs./sec, respectively. In these optimum conditions, the resistivity and the carrier concentration were 5.3*10$\^$-3/ .ohm.-cm, 6.5*10$\^$20/cm$\^$-3/, and the transmittance was over 80%. From the results of J-V measurements in ITO/p-InP structure solar cells, the higher pressure of injected oxygen, the more open circuit voltage. The efficiency of ITO/p-InP solar cell without the grid line contact, prepared by the optimum evaporation conditions, was 7.19%. By using the grid line contact, the efficiency, the open circuit voltage, the short circuit current density, the fill factor, the series resistance, and the shunt resistance were 8.5%, 0.47V, 29.48 mAcm$\^$-2/ , 61.35%, 3.ohm., and 26.6k.ohm., respectively.

  • PDF

Optimization of MgO Evaporation for PDP Efficiency and Discharging Characterization (프라즈마 디스플레이 패널의 고효율화를 위한 MgO 증착 조건의 최적화 및 PDP 방전특성 분석)

  • Kwon, Sang-Jik;Kim, Yong-Jae;Li, Zhao-Hui;Kim, Kwang-Ho;Yang, Soon-Seuk
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.569-570
    • /
    • 2006
  • Effects of the evaporation rate of MgO films using electron beam were investigated on the MgO properties and the discharge characteristics of the plasma display panel (PDP). The evaporation rate was changed from $3{\AA}$/sec to $15{\AA}$/sec at a substrate temperature of $300^{\circ}C$. MgO properties such as crystal orientation, surface roughness, contact angle, and film structure were inspected using XPS, AFM, drop shape analysis and SEM. We also studied the relation between MgO properties and PDP discharging characteristics. The minimum firing voltage and maximum efficacy were obtained at evaporation rate of $5{\AA}$/sec. In the MgO film deposited at $5{\AA}$/sec, (200) orientation was most intensive and surface roughness was minimum.

  • PDF

Performance analysis of R404A refrigeration system using R744 as secondary refrigerant (R744를 2차냉매로 사용하는 R404A용 냉동시스템의 성능 분석)

  • Oh, H.K.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.2
    • /
    • pp.24-29
    • /
    • 2012
  • In this paper, an analysis on performance and exergy of R404A refrigeration system using R744 secondary refrigerant was performed numerically to optimize the design for the operating parameters. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporation and condensation temperature in the R404A refrigeration cycle and temperature difference of cascade heat exchanger. The main results are summarized as follows : The COP(coefficient of performance) of R404A refrigeration system increases with increasing evaporation temperature. The evaporation capacity of R744 as secondary refrigerant increases with the increase in evaporation pressure of R744 secondary refrigeration. And the enthalpy in the evaporator outlet of R744 increases with the increasing evaporation pressure of R744 secondary refrigeration. Therefore, it is important to analysis for the relationship between COP of R404A refrigeration system and refrigeration capacity of R744. As cascade evaporation temperature increase, the exergy loss of condenser and compressor using R404A is the largest among all components. Therefore, the exergy loss in the condenser and compressor using R404A must be decreased to enhance the COP of R404A refrigeration system with R744 secondary refrigerant.

Experiments on Operation Characteristics of In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열 시스템의 운전특성 실험)

  • Choe, In-Su;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.653-659
    • /
    • 2001
  • This paper is concerned with the development of a new method for making and separating ice in-water and saving floated ice by installing an evaporation panel in an ice storage tank. The new method shows very good heat transfer efficiency than that of the convectional method. It is because the evaporation panel is directly contacted with water in the storage tank. The experiments were performed by varying inlet and outlet refrigerant temperatures of its evaporator. From the experimental results, the operating characteristics of in-water harvest-type ice storage system were investigated by measuring temperature and pressure at each point of the ice storage system and power required to operating compressor respect to the changes of the inlet and outlet refrigerant temperature of evaporator. It can be think that defrost frequency decreased and heavy ice created as the refrigerant temperature of evaporator outlet and defrost setting temperature is low so gotten result can effect to release efficiency. Also, consumption power, condensing heat quantity, refrigerating capacity and performance efficiency decreased as time goes by. Therefore, these results provide the basic data for system optimization, performance improvement and the possibility of application to other fields.

A Comparative Study on Diesel Engine Performance with Higher Alcohol-diesel Blends (고탄소알코올/경유 혼합유를 이용한 디젤엔진 성능 특성 비교 )

  • JAESUNG KWON;JEONGHYEON YANG;BEOMSOO KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.6
    • /
    • pp.767-772
    • /
    • 2023
  • In this study, combustion experiments were conducted at various engine speeds under full-load conditions using a single-cylinder diesel engine by blending butanol, pentanol, and octanol with diesel at a volume ratio of 10%. Experimental results revealed that higher alcohol-diesel blends resulted in lower brake torque and brake power than pure diesel due to the lower calorific value and the cooling effect during evaporation. An evident improvement in the brake thermal efficiency of the blended fuels was observed at engine speeds below 2,000 rpm, with the butanol blend exhibiting the highest thermal efficiency overall. Furthermore, the brake-specific fuel consumption of the higher alcohol-diesel blends was lower than that of pure diesel at speeds below 2,200 rpm. When using blended fuels, the exhaust gas temperature decreased under lean mixture conditions due to heat loss to the air and the cooling effect from fuel evaporation.

Effect of Defect Energy levels on the AC PDP Discharging Characteristics (MgO 보호막의 결함 전위 레벨이 AC-PDP 방전 특성에 미치는 효과)

  • Kwon, Sang-Jik;Kim, Yong-Jae;Cho, Eou-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.12
    • /
    • pp.12-17
    • /
    • 2007
  • The effects of the evaporation rate of MgO films using an electron beam on the MgO properties and the discharge characteristics of a plasma display panel(PDP) were investigated and analyzed. Mgo films were deposited with the various MgO evaporation rates. The MgO properties such as the crystal orientation, the surface roughness, and the film structure, were inspected using XRD(X-ray diffractometry), AFM(atomic force microscopy). From the experiments and Paschen law, the maximum value of the secondary, electron emission coefficient $(\gamma)$ was obtained at the evaporation rate of $5\AA/sec$. The minimum firing voltage and the maximum luminous efficiency were obtained at an evaporation rate of $5\AA/sec$. In the MgO film deposited at $5\AA/sec$, the (200) orientation and $F^+$ center were most intensive. The XRD results and cathode-luminescence(CL) spectra show the $\gamma$ values are correlated with $F/F^+$ centers of the molecular structure of MgO films.

Recovery of Silver and Nitric Acid in the Liquid Waste Resulted from the Mediated Electrochemical Oxidation Process (전기화학적 매개산화공정 폐액에서 은 및 질산의 회수)

  • 최왕규;김영민;이근우;박상윤;오원진
    • Resources Recycling
    • /
    • v.7 no.3
    • /
    • pp.17-26
    • /
    • 1998
  • A study on the recovery of silver and nitric acid in the liquid waste resulted from the mediated electrochemical oxidation(MEO) process was conducted. The removal of silver in the concentrated nitric acid solutions was carried out by the electrodeposition. The removal efficiency more than 98% could be obtained in nitric acid concentrations less than 3 M with the current efficiency of nearly 100%. The experimonts on the evaporation for the recovery of nitric acid were performed as well. At the evaporation factor of 25., the degree of nitric acid recovery in 3.5 M nitric acid solution containing 0.5 to 1.0 mol% NaNO, was 80~90% resulting in 2.8~3.1 M nitric acid. The design factors and operating conditions of the distillation tower were analyzed by using MEH model derived by Maphtali-Sandholm with the throughput of 4 kg/hr for the enrichment of dilute nitric acid solution recovered by evaporation to reuse in the MEO process. The distillation column composed of eleven theoretical stages having the overall tray efficiency of 70% are needed to obtain 1.03 kg/h of 12M nitric acid and 2.97 kg/h of water with feed being introduced to the column at tray 6 from the bottom at the reflux ratio of 0.25, the reboiler with the heat load of 2.7 kW, and the condenser with the cooling load of 0.5 kW.

  • PDF

Self-developed Efficiency Measurement System of Organic Light-Emitting Diodes (자체 개발한 유기 발광 소자의 효율 측정 시스템)

  • Han, Wone-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.537-538
    • /
    • 2005
  • A way of measuring an efficiency of organic light-emitting diodes are studied. The efficiency is obtained from the current-voltage-luminance characteristics of the devices. Basically, number of charge carriers are obtained from the current-voltage characteristics, and the number of photons are obtained from the current of Si-photodetector. The organic light-emitting diodes are assumed as a lambertian light source and a program is made for calculating the efficiency. A device structure of ITO/TPD/$Alq_3$/Al is manufactured using thermal-vapor evaporation. This device is set into a measuring system and measured the efficiency. The efficiencies are measured using the lab-made program and commercially available equipments. The obtained values are similar to each other within 10% uncertainty.

  • PDF