• 제목/요약/키워드: Evaporation efficiency

검색결과 426건 처리시간 0.027초

진공 열 증착 기반의 정공수송층 적용을 통한 페로브스카이트 태양전지 (Perovskite Solar Cells through Application of Hole Transporting Layers based on Vacuum Thermal Evaporation)

  • 김혜승;송명훈
    • Current Photovoltaic Research
    • /
    • 제10권1호
    • /
    • pp.23-27
    • /
    • 2022
  • In this study, we investigate organic-inorganic halide perovskite solar cells with a vacuum thermal evaporated hole transporting layer (NPB/MoO3-x). By replacing solution process based Spiro-MeOTAD with vacuum thermal evaporation based NPB/MoO3-x, a thin hole transporting layer was implemented. In addition, parasitic absorption that may occur during the doping process was eliminated by excluding solution process doping. In a solar cell with a thin vacuum thermal evaporated hole transporting layer, the short-circuit current density (Jsc) increased to 23.93 mA/cm2, resulting in the highest power converstion efficiency (PCE) at 18.76%. Considering these results, it is essential to control the thickness of hole transporting layer located at the top in solar cell configuration.

온배수를 이용한 혼합냉매용 해양온도차 발전 사이클의 성능 특성 (Performance Characteristics of a Mixed Refrigerant OTEC Power Cycle Using Hot Waste Water)

  • 윤정인;손창효;허정호;예병효;김현주;이호생
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.102-107
    • /
    • 2013
  • In this paper, the performance analysis for evaporation capacity, total work and efficiency of the ocean thermal energy conversion(OTEC) power system using mixed refrigerant(R32,R152a) is conducted to find the effect of hot wasted water on OTEC power system. The system in this study is applied with two stage turbine, regenerator, cooler and separator on Organic Rankine Cycle. The commercial program HYSYS is used for the performance analysis. The main results were summarized as follows : The efficiency of the OTEC power cycle has a largely effect on the evaporation capacity and total work. As increasing temperature of heat source water, evaporator's capacity is decreased but total work increase. Otherwise, using hot wasted water bring effects not only increasing system efficiency but also declining evaporator's capacity. Thus With a thorough grasp of these effect, it is necessary to find way to use hot wasted water emitted by power plant and so on.

ITO/p-InP 태양전지 제작 (The fabrication of ITO/p-InP solar cells)

  • 맹경호;김선태;송복신;문동찬
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권3호
    • /
    • pp.243-251
    • /
    • 1994
  • ITO(Indium Tin Oxide) film with thickness of 1500.angs. was prepared by an e-beam evaporator onto a glass and a p-type InP wafer (100) LEC grown Zn-doped p=2.3*10$\^$16/cm$\^$-3/), in which the components of ITO used for evaporation source were hot pressed pellets 1 mole% ln$\_$2/O$\_$3/+9 mole% SnO$\_$2/, and evaporated in O$\_$2/ ambient. The optimum conditions to preparation of ITO thin film were the substrate temperature of 350.deg. C, the injected oxygen pressure of 2*10$\^$-4/ torr, and the evaporation speed of 0.2-0.3.angs./sec, respectively. In these optimum conditions, the resistivity and the carrier concentration were 5.3*10$\^$-3/ .ohm.-cm, 6.5*10$\^$20/cm$\^$-3/, and the transmittance was over 80%. From the results of J-V measurements in ITO/p-InP structure solar cells, the higher pressure of injected oxygen, the more open circuit voltage. The efficiency of ITO/p-InP solar cell without the grid line contact, prepared by the optimum evaporation conditions, was 7.19%. By using the grid line contact, the efficiency, the open circuit voltage, the short circuit current density, the fill factor, the series resistance, and the shunt resistance were 8.5%, 0.47V, 29.48 mAcm$\^$-2/ , 61.35%, 3.ohm., and 26.6k.ohm., respectively.

  • PDF

프라즈마 디스플레이 패널의 고효율화를 위한 MgO 증착 조건의 최적화 및 PDP 방전특성 분석 (Optimization of MgO Evaporation for PDP Efficiency and Discharging Characterization)

  • 권상직;김용재;이조휘;김광호;양순석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.569-570
    • /
    • 2006
  • Effects of the evaporation rate of MgO films using electron beam were investigated on the MgO properties and the discharge characteristics of the plasma display panel (PDP). The evaporation rate was changed from $3{\AA}$/sec to $15{\AA}$/sec at a substrate temperature of $300^{\circ}C$. MgO properties such as crystal orientation, surface roughness, contact angle, and film structure were inspected using XPS, AFM, drop shape analysis and SEM. We also studied the relation between MgO properties and PDP discharging characteristics. The minimum firing voltage and maximum efficacy were obtained at evaporation rate of $5{\AA}$/sec. In the MgO film deposited at $5{\AA}$/sec, (200) orientation was most intensive and surface roughness was minimum.

  • PDF

R744를 2차냉매로 사용하는 R404A용 냉동시스템의 성능 분석 (Performance analysis of R404A refrigeration system using R744 as secondary refrigerant)

  • 오후규;손창효
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.24-29
    • /
    • 2012
  • In this paper, an analysis on performance and exergy of R404A refrigeration system using R744 secondary refrigerant was performed numerically to optimize the design for the operating parameters. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporation and condensation temperature in the R404A refrigeration cycle and temperature difference of cascade heat exchanger. The main results are summarized as follows : The COP(coefficient of performance) of R404A refrigeration system increases with increasing evaporation temperature. The evaporation capacity of R744 as secondary refrigerant increases with the increase in evaporation pressure of R744 secondary refrigeration. And the enthalpy in the evaporator outlet of R744 increases with the increasing evaporation pressure of R744 secondary refrigeration. Therefore, it is important to analysis for the relationship between COP of R404A refrigeration system and refrigeration capacity of R744. As cascade evaporation temperature increase, the exergy loss of condenser and compressor using R404A is the largest among all components. Therefore, the exergy loss in the condenser and compressor using R404A must be decreased to enhance the COP of R404A refrigeration system with R744 secondary refrigerant.

수중 하베스트형 빙축열 시스템의 운전특성 실험 (Experiments on Operation Characteristics of In-Water Harvest-Type Ice Storage System)

  • 최인수;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.653-659
    • /
    • 2001
  • This paper is concerned with the development of a new method for making and separating ice in-water and saving floated ice by installing an evaporation panel in an ice storage tank. The new method shows very good heat transfer efficiency than that of the convectional method. It is because the evaporation panel is directly contacted with water in the storage tank. The experiments were performed by varying inlet and outlet refrigerant temperatures of its evaporator. From the experimental results, the operating characteristics of in-water harvest-type ice storage system were investigated by measuring temperature and pressure at each point of the ice storage system and power required to operating compressor respect to the changes of the inlet and outlet refrigerant temperature of evaporator. It can be think that defrost frequency decreased and heavy ice created as the refrigerant temperature of evaporator outlet and defrost setting temperature is low so gotten result can effect to release efficiency. Also, consumption power, condensing heat quantity, refrigerating capacity and performance efficiency decreased as time goes by. Therefore, these results provide the basic data for system optimization, performance improvement and the possibility of application to other fields.

고탄소알코올/경유 혼합유를 이용한 디젤엔진 성능 특성 비교 (A Comparative Study on Diesel Engine Performance with Higher Alcohol-diesel Blends)

  • 권재성;양정현;김범수
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.767-772
    • /
    • 2023
  • In this study, combustion experiments were conducted at various engine speeds under full-load conditions using a single-cylinder diesel engine by blending butanol, pentanol, and octanol with diesel at a volume ratio of 10%. Experimental results revealed that higher alcohol-diesel blends resulted in lower brake torque and brake power than pure diesel due to the lower calorific value and the cooling effect during evaporation. An evident improvement in the brake thermal efficiency of the blended fuels was observed at engine speeds below 2,000 rpm, with the butanol blend exhibiting the highest thermal efficiency overall. Furthermore, the brake-specific fuel consumption of the higher alcohol-diesel blends was lower than that of pure diesel at speeds below 2,200 rpm. When using blended fuels, the exhaust gas temperature decreased under lean mixture conditions due to heat loss to the air and the cooling effect from fuel evaporation.

MgO 보호막의 결함 전위 레벨이 AC-PDP 방전 특성에 미치는 효과 (Effect of Defect Energy levels on the AC PDP Discharging Characteristics)

  • 권상직;김용재;조의식
    • 대한전자공학회논문지SD
    • /
    • 제44권12호
    • /
    • pp.12-17
    • /
    • 2007
  • 본 연구에서는 전자빔 증착의 증착률이 MgO 보호막의 특성과 제작된 PDP의 방전 특성에 주는 영향에 대하여 연구, 분석 하였다. MgO 박막을 여러 조건의 증착률로 증착하였고, 이 후 결정 구조, 표면 거칠기, 박막 구조와 같은 특성을 XRD, AFM 등을 사용하여 측정, 평가하였다. 실험 결과와 Paschen law을 통해서 $5\AA/sec$의 증착률에서 이차전자방출이 최대가 되는 것을 확인할 수 있었으며, 동일 조건에서 방전 전압이 가장 작고, 발광 효율은 가장 큰 값을 갖는 것이 확인되었다. 또한 $5\AA/sec$의 (200) 결정 방향과 $F^+$ center 측정값도 가장 높게 측정되었다. XRD와 CL 스펙트럼의 결과를 통하여 이차전자방출계수가 MgO 박막의 분자 결정상의 $F/F^+$ centers구조와 관련 있음을 확인할 수 있었다.

전기화학적 매개산화공정 폐액에서 은 및 질산의 회수 (Recovery of Silver and Nitric Acid in the Liquid Waste Resulted from the Mediated Electrochemical Oxidation Process)

  • 최왕규;김영민;이근우;박상윤;오원진
    • 자원리싸이클링
    • /
    • 제7권3호
    • /
    • pp.17-26
    • /
    • 1998
  • 전기화학적 매개산화 공정에서 발생하는 질산 폐액으로부터 은 및 고농도 질산을 회수하기 위한 연구를 수행하였다. 고농도 질산용액 내에 포함된 은의 회수는 전착법으로 이루어졌으며, 질산농도 3M이하에서는 거의 100%의 전류효율로 98% 이상의 은을 회수할 수 있었다. 또한 질산의 회수를 위한 증발 실험이 수행되었으며, 증발률이 25에서 0.5~1.0mol%의$ NaNO_3$를 함유한 3.5M의 질산 공급폐액으로부터 질산의 절대회수율은 약 80~90%로써 2.8~3.1m의 질산을 얻을 수 있었다. 증발공정에서 회수된 묽은 질산 용액을 고농도 질산용액으로 농축하여 MEO 공정에 재사용하기 위한 처리용량 4kg/hr인 증류탑의 설계 인자 및 운전조건을 Naphtali-Sandholm의 MEH 모델을 사용하여 계산하였다. 단 효율이 70% 이상인 11개의 단으로 구성된 증류탑의 공급단을 6단으로 하고 환류비 0.25, 재비기 열용량 2.7㎾, 응축기 열량 0.5㎾로 운전할 경우 시간당 1.03kg의 12M 질산용액과 2.97kg의 물을 얻을수 있었다.

  • PDF

자체 개발한 유기 발광 소자의 효율 측정 시스템 (Self-developed Efficiency Measurement System of Organic Light-Emitting Diodes)

  • 한원근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.537-538
    • /
    • 2005
  • A way of measuring an efficiency of organic light-emitting diodes are studied. The efficiency is obtained from the current-voltage-luminance characteristics of the devices. Basically, number of charge carriers are obtained from the current-voltage characteristics, and the number of photons are obtained from the current of Si-photodetector. The organic light-emitting diodes are assumed as a lambertian light source and a program is made for calculating the efficiency. A device structure of ITO/TPD/$Alq_3$/Al is manufactured using thermal-vapor evaporation. This device is set into a measuring system and measured the efficiency. The efficiencies are measured using the lab-made program and commercially available equipments. The obtained values are similar to each other within 10% uncertainty.

  • PDF