• 제목/요약/키워드: Evaporating Temperature

검색결과 265건 처리시간 0.022초

Numerical Analysis of Pulsating Heat Pipe Based on Separated Flow Model

  • Kim Jong-Soo;Im Yong-Bin;Bui Ngoc Hung
    • Journal of Mechanical Science and Technology
    • /
    • 제19권9호
    • /
    • pp.1790-1800
    • /
    • 2005
  • The examination on the operating mechanism of a pulsating heat pipe (PHP) using visualization revealed that the working fluid in the PHP oscillated to the axial direction by the contraction and expansion of vapor plugs. This contraction and expansion is due to the formation and extinction of bubbles in the evaporating and condensing section, respectively. In this paper, a theoretical model of PHP was presented. The theoretical model was based on the separated flow model with two liquid slugs and three vapor plugs. The results show that the diameter, surface tension and charge ratio of working fluid have significant effects on the performance of the PHP. The following conclusions were obtained. The periodic oscillations of liquid slugs and vapor plugs were obtained under specified parameters. When the hydraulic diameter of the PHP was increased to d=3mm, the frequency of oscillation decreased. By increasing the charging ratio from 40 to 60 by volume ratio, the pressure difference between the evaporating section and condensing section increased, the amplitude of oscillation reduced, and the oscillation frequency decreased. The working fluid with higher surface tension resulted in an increase in the amplitude and frequency of oscillation. Also the average temperature of vapor plugs decreased.

증발식 해수담수화설비의 에너지 소모량에 관한 연구 (A study on the required energy of a thermal type desalination plant)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1094-1100
    • /
    • 2014
  • 오폐수처리, 해수담수화 및 식품산업의 경우 증발과정은 필수공정이며, 이는 기본적으로 용액으로부터 용매인 순수한 물성분을 추출하여 점차 용액의 농도를 증가시키는 방식이다. 농축을 위한 방식은 전기투석, 증발식, 막방식 등의 다양한 방법이 사용되고 있으나, 본 연구에서는 여러 산업분야에서 적용되고 있는 증발식을 대상으로 운전방식에 따른 가열열원의 소모량을 이론적으로 분석하고, 이에 근거하여 다단증발식 해수담수화설비의 운전특성을 파악하였다. 본 연구의 결과에 따르면 시스템에서 이용할 수 있는 전체 온도차, 즉 인입해수의 온도와 1단 증발부로 유입되는 해수온도와의 차를 기준으로 증발단의 수를 증가시킬수록 에너지효율이 상승함을 알 수 있었다.

A Study on the Behavior of Evaporating Diesel Spray Using LIEF Measurement and KIVA Code

  • Yeom, Jeong-Kuk;Chung, Sung-Sik;Ha, Jong-Yul;Kim, Yong-Rae;Min, Kyoung-Doug
    • Journal of Mechanical Science and Technology
    • /
    • 제18권12호
    • /
    • pp.2310-2318
    • /
    • 2004
  • The effects of change in injection pressure on spray structure in high temperature and pressure field have been investigated. The analysis of liquid and vapor phases of injected fuel is important for emissions control of diesel engines. Therefore, this work examines the evaporating spray structure using a constant volume vessel. The injection pressure is selected as the experimental parameter, is changed from 400 bar to 800 bar by using a common rail injection system. Also, we conducted simulation study by modified KIVA-II code. The results of simulation study are compared with experimental results. The images of liquid and vapor phase for free spray were simultaneously taken by exciplex fluorescence method. As experimental results, the vapor concentration of injected fuel is leaner due to the increase of atomization in the case of the high injection pressure than in that of the low injection pressure. The calculated results obtained by modified KIVA-II code show good agreements with experimental results.

공조.냉동장치의 제어시스템 개발을 위한 팽창밸브 특성 (Expansion Valves Characteristics for Development of Control System on Air Conditioning and Refrigeration Systems)

  • 김재돌;장재은;윤정인
    • 동력기계공학회지
    • /
    • 제2권3호
    • /
    • pp.34-40
    • /
    • 1998
  • Performance characteristics of a refrigeration systems with various expansion valves and superheat changes were investigated experimentally. Experimental data have been taken utilizing three different devices; a thermostatic expansion valve, a linear type electronic expansion valve and a solenoid type electronic expansion valve. The data taken from tile three types of expansion valves were discussed with the temperature distribution of each zone in the evaporator and the superheat changes of the evaporator outlet In each zone temperature distribution fluctuated larger with the thermostatic expansion valve than with the electronic expansion valves. The optimum superheat ranged from $5^{\circ}C\;to\;15^{\circ}C$, and the superheat with the thermostatic expansion valve showed hunting phenomenon, which affected the evaporating and condensing temperature.

  • PDF

가시용 직분식 디젤기관의 분무와 화염에 관한 연구 (A study on the spray and flame by optically accessible D.I. diesel engine : analysis by Schlieren method and diffused background illumination method)

  • 안수길;이덕보;라진홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권3호
    • /
    • pp.9-23
    • /
    • 1995
  • To analyze the spray and flame in D.I. diesel engine, the visualizing methods by schlieren photograph and diffused background illumination photograph with high speed camera are applied to optically accessible D.I.diesel engine. Wcaporating spray, spray droplets and brightness flame are taken with high speed camera by visuallizing method in accordance with various suction air temperature and injection time. The spray and flame image on the film was analyzed by image analyzer. The optically accessible D.I. diesel engine had the similar pressure characteristic to the real D.I. diesel engine. Experimental results showed that shadow areas of the evaporating spray were extended at higher suction air temperature, spray droplets had a max. Penetration length and their penetrating patterns were dependent on the surrounding gas temperature, and flame size after ignition was largely governed by the evaporated fuel quantity at ignition point and by the surrounding gas condition due to piston motion.

  • PDF

고온 표면에 부착된 증발 액적에 의한 열유속 변화 추정 (The Evaluation of Heat Flux by Evaporating Droplet on the Hot Surface)

  • 신운철;배신철
    • 대한기계학회논문집B
    • /
    • 제31권9호
    • /
    • pp.764-771
    • /
    • 2007
  • The objective of the present work is to evaluate the evaporation heat flux of deposited droplet on the hot surface by using of inverse heat transfer technique. On the basis of measured temperature, a integral form solution is determined for the transient temperatures beyond the two positions by using Green's function technique. This method first approximates the temperature data with a half polynomial series of time. we compared this result with constant radius model in single phase regime, nucleate boiling regime, film boiling regime respectively. this paper performed the experiments as following conditions: (a)the surface temperature is within the range between $80^{\circ}C\;and\;160^{\circ}C$ in the conduction, (b) droplet diameter are 2.4 and 3.0mm. (c) surface roughness is $0.18{\mu}m$.

냉동공조용 관군에서의 서리발생 및 제상 메커니즘에 관한 연구 (Study on frost Generation and Defrosting Mechanism on Evaporating Tubes for Refrigerator and Air condition industries)

  • 지재훈;김창복;문성배;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.234-235
    • /
    • 2005
  • In this experiment study, to acquire elementary data for explaining to generate frost layer in the fin - tube evaporator. the experiment condition is to supply air on 0.3m/s, 0.6m/s, 0.9m/s and inlet air temperature is 15$^{circ}C$, 20$^{circ}C$, 25$^{circ}C$ , supplied air relative humidity is 70%, 80, 90%. And brine temperature in the copper tube was kept -15$^{circ}C$ because, generally cooling temperature range is constantly -15$^{circ}C$ in the heat exchanger for air conditioning system. in conclusion, through this experiment, we did compare with frost layer and frost thickness in each condition and examine these data

  • PDF

냉동공조용 증발기에서 서리의 발생 및 제상 메커니즘에 관한 연구 (A study on frost generation and difrosting mechanism on evaporating tubes for Air-conditioning system)

  • 지재훈;김창복;김명환;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.166-171
    • /
    • 2005
  • In this experiment study, to acquire elementary data for explaining to generate frost layer in the fin - tube evaporator. the experiment condition is to supply air on 0.3m/s, 0.6m/s, 0.9m/s and inlet air temperature is kept constantly $20^{\circ}C$, supplied air relative humidity is 70%, 80, 90%. And brine temperature in the copper tube was kept $-15^{\circ}C$ because, generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system. in conclusion, through this experiment, we did compare with frost layer and frost quantity in each condition and examine these data

  • PDF

저온열원 활용을 위한 유기랭킨사이클의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Organic Rankine Cycles for Use of Low-Temperature Heat Source)

  • 진재영;김경훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.191-194
    • /
    • 2011
  • Low-grade waste heat has generally been discarded in industry due to lack of efficient recovery methods. In recent years, organic Rankine cycle(ORC) has become a field of intense research and appears as a promising technology for conversion of heat into useful work of electricity. In this work thermodynamic performance of ORC with superheating of vapor is comparatively assessed for various working fluids. Special attention is paid to the effects of system parameters such as the evaporating temperature on the characteristics of the system such as maximum possible work extraction from the given source, volumetric flow rate per 1 kW of net work and quality of the working fluid at turbine exit as well as thermal efficiency.

  • PDF

레이저 용접시 분광학적 수법에 의한 증발입자의 거동과 플라즈마 물성의 계측 (Evaporating Particle Behaviors and plasma Parameters by Spectroscopic Method in laser Welding)

  • 김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.514-522
    • /
    • 1999
  • The laser-induced plasma affects greatly on the results of welding process. moreover selective evaporation loss of alloying elements leads to change in chemical composition of weld metal as well as the mechanical properties of welded joint. this study was undertaken to obtain a fundamental knowledge of pulsed laser welding phenomena especially evaporation mechanism of different aluminum alloys. The intensities of molecular spectra of AlO and MgO were different each other depeding on the power density of a laser beam Under the low power density condition the MgO band spectrum was predominant in intensity while the AlO spectra became much stronger with an increase in the power density. These behaviors have been attributed to the difference in evaporation phenomena of Al and Mg metals with different boiling points and latent heats of vaporization. The time-averaged plasma temperature and electron number density were determined by spectroscopic methods and consequently the obtained temperature was $3,280{\pm}150K$ and the electron number density was $1.85{\times}10^{19}\;l/m^3$.

  • PDF