• 제목/요약/키워드: Evaporating Temperature

검색결과 265건 처리시간 0.022초

터보과급 디이젤기관의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Turbocharged Diesel Engine)

  • 채재우;정성찬;백중현
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.76-86
    • /
    • 1994
  • Combustion of diesel engine depends on the mixing of air and evaporating fuel during ignition delay greatly. Variation of air-fuel mixing rate and ignition delay for engine operating condition causes difference of combustion, performance and exhaust emissions. This study is investigated in a turbocharged diesel engine of IDI swirl chamber type. In the results, As injection timing is advanced until $12.6^{\circ}$ BTC, ignition delay decreases. NOx concentration and smoke level in exhaust gas increases for advanced injection timing Ignition delay, combustion period, pressure rise rate and exhaust gas temperature are increased with increasing engine speed. And ignition delay at high load is more decreased than that at low load. Ignition delay and combustion period are decreased with increasing intake pressure. Power increases, temperature and CO, NOx concentration in exhaust gas decreases as intake pressure increases. With increasing load, ignition delay is decreased and combustion period, motoring pressure are increased.

  • PDF

Performance Characteristics of a Household Refrigerator with Dual Evaporators Using Two-Stage Compression Cycle

  • Joo, Young-Ju;Kim, Young-Heon;Lee, Moo-Yeon;Yoon, Won-Jae;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권3호
    • /
    • pp.107-113
    • /
    • 2009
  • The objective of this study is to investigate performance characteristics of a household refrigerator using a two-stage compression cycle. The performance of the two-stage compression cycle was measured by varying the compressor speed, condensing temperature, and evaporating temperature. The COP of the two-stage compression cycle was analyzed and then compared with that of the single-stage compression cycle. The optimum combination of compressor speeds for a low- and a high-stage was determined. The COP of the two-stage compression cycle using a PTC (parallel two-stage compression) method was 5.85% higher than that of a STC (serial two-stage compression) method at optimum operating conditions.

해수냉각시스템용 Aluminium Brass Tube의 R-134a 증발열전달 특성 (Evaporating heat transfer characteristics of Aluminum-brass tube for seawater cooling system using R-134a)

  • 강인호;설성훈;윤정인;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.197-201
    • /
    • 2017
  • 대부분의 어선에서는 포획된 어류를 관리하고 저장하기 위해 얼음 냉각 시스템을 사용한다. 그러나 얼음 냉각 시스템은 작동 시간의 제한뿐만 아니라 적절한 온도와 염분 농도를 유지하는 것이 어려운 단점이 있다. 본 연구의 목적은 어류 운반선의 어창에 적정한 해수온도 유지를 위한 해수 냉각 시스템용 만액식 증발 열전달 특성을 파악하는데 있다. 실험은 냉매의 해수 온도, 유량 및 포화 온도의 변화를 주며 열전달 특성을 파악하였다. 동일 열유속에서 Aluminium-Brass tube가 Copper-Nickel tube 보다 외측 열전달계수가 약 10% 큰 것으로 확인할 수 있었으며, 이를 통해 해수용 열교환기의 전열관으로 Aluminium-Brass를 적용하는 것이 열전달 측면에서 효과적일 것을 확인할 수 있었다. 만액식 단관 열전달계수와 18 kW급 만액식 해수냉각시스템의 총괄열전달계수의 비교를 통해 동일 조건에서는 25%정도 단관의 열전달계수가 큰 값을 나타내었으며, 이러한 결과는 만액식 관군 열교환기의 설계를 위한 중요한 자료가 되리라 판단된다.

R-502 대체 혼합냉매의 성능에 관한 실험적 연구 (Experimental study on the performance of R-502 alternative refrigerant mixtures)

  • 박동민;정동수;김종보;강득주
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.198-209
    • /
    • 1997
  • This paper is concerned about the performance of alternative refrigerants of R-502 which has been widely used in transport and low temperature refrigeration. A breadboard heat pump was constructed with counterflow heat exchangers and tested with R-502 and transitional alternatives of R-402A and R-402B and long-term alternatives of R-404A and R-507 to compare the performance of each refrigerant. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$ and $52.0^{\circ}C$ and the evaporating temperature was varied over a range from $-25^{\circ}C$ to $-5^{\circ}C$. The evaporator superheat and condenser subcooling were maintained constant at about $5^{\circ}C$ for all tests. Test results showed that all alternative fluids tested in this research work can be used as 'drop-in' fluids to replace R-502 without any major problem. It is also found that in the long run HFC alternatives are to be used due to their favorable environmental characteristics and better performance.

  • PDF

연근해 어선용 해수냉각장치의 열부하특성 (Heat Load Characteristics of Sea Water Cooling Apparatus on Inshore Fishing Boat)

  • 한인근;문춘근;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1317-1323
    • /
    • 2001
  • The circumstance is giving the blow against fishermen with the incoming-decreasing and the difficulty of crew's supply & demand and management. In addition, the depression of the external situation like the departure of WTO system and the plan of EEZ proclaim is forcing fishery into improving their fishing condition. By this international and domestic circumstance, development of the sea water cooling apparatus for fish hold storage is demanded sincerely. First of all, we Investigated load characteristics which based on development of sea water cooling system and optimum fish hold storage. The experimental results is as follows. In creasing the speed of compressor and mass blew rate of refrigerant, the temperature of NaCl solution is low. And the load characteristics experiment on fish hold storage outlet is as fellows. As time goes by, increasing the mass flow rate of NaCl solution, temperature difference between inlet and outlet is small in a model of fish hold storage. These results provide many useful informations applicable to an actual design of sea water cooling system and optimum fish hold storage.

  • PDF

미세폭발을 가진 혼화 이성분 연료 액적의 증발 현상 (Microexplosive Vaporization of Miscible Binary Fuel Droplets)

  • 호잿가세미;백승욱;카심살월칸
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.120-131
    • /
    • 2005
  • The evaporation characteristics of single and multicomponent droplets hanging at the tip of a quartz fiber are studied experimentally at the different environmental conditions under normal gravity. Heptane and Hexadecane are selected as two fuels with different evaporation rates and boiling temperatures. At the first step, the evaporation of single component droplet of both fuels has been examined separately. At the next step the evaporation of several blends of these two fuels, as a binary component droplet, has been studied. The temperature and pressure range is selected between 400 and 700 $^{\circ}C$, and 0.1 and 2.5 MPa, respectively. High temperature environment has been provided by a falling electrical furnace. The initial diameter of droplet was in range of 1.1 and 1.3 mm. The evaporation process was recorded by a high speed CCD camera. The results of binary droplet evaporation show the three staged evaporation. In the the first stage the more volatile component evaporates. The droplet temperature rises after an almost non evaporating period and in the third stage a quasi linear evaporation takes place. The evaporation of the binary droplet at low pressure is accompanied with bubble formation and droplet fragmentation and leads to incomplete microexplosion. The component concentration affects the evaporation behavior of the first two stages. The bubble formation and droplet distortion does not appear at high environment pressure. Nomenclature

  • PDF

진공고주파를 이용한 일체형 건조기개발에 관한 연구 (A Study on an Integrated Drying Machine with Microwave at Vacuum Conditions)

  • 김태형;고광수;박윤철
    • 설비공학논문집
    • /
    • 제26권9호
    • /
    • pp.441-446
    • /
    • 2014
  • In Jeju province, the Citrus is widely spread crop which is the most popular fruit on the island. When the quality of a Citrus is not in a good condition or when its size exceeds or is lower than the set criteria, it is discarded as a waste. In this study, a drying machine for waste Citrus has been developed with 2.6 GHz microwave energy supply to the Citrus at vacuum environment. The vacuum environment of the drying chamber was maintained to reduce the energy supply to the Citrus by lowering the evaporating temperature of the water. The experiment was conducted with variation of the vacuum pressure, interior temperature of the drying chamber, and operating time of the microwave. As a result, the effect of the temperature was shown to be higher than the other two control methods, and it showed with 0.305 g/W evaporation efficiency.

보조 외부 증발기를 이용한 히트펌프 건조기 성능 향상에 관한 연구 (A Study on Performance Improvement of a Heat Pump Dryer with an Extra Evaporator Outside)

  • 이영림;박상준;황일선
    • 설비공학논문집
    • /
    • 제24권10호
    • /
    • pp.711-717
    • /
    • 2012
  • A heat pump dryer for the frozen food needs to preheat the air to a certain temperature where condensation can efficiently occur. In this study, an analysis of a heat pump dryer performance with operating conditions, an analysis of supplying heat with internal and external evaporators and a warm-up experiment with the evaporators have been performed. The results showed that the external evaporator can significantly accelerate the warm-up time of the dryer, so that it can reduce power consumption greatly. The use of the external evaporator is more efficient for higher ambient temperature. In addition, it was found that COP decreases and the range of evaporating pressure for the evaporator becomes narrower as the condensing temperature of the condenser increases.

고발열 CPU 냉각용 증기 압축식 냉각 시스템의 증발기 최적화 (Optimization of Evaporator for a Vapor Compression Cooling System for High Heat Flux CPU)

  • 김선창;전동순;김영률
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.255-265
    • /
    • 2008
  • This paper presents the optimization process of evaporator for a vapor compression cooling system for high heat flux CPU. The CPU thermal capacity was given by 300W. Evaporating temperature and mass flow rate were $18^{\circ}C$ and 0.00182kg/s respectively. R134a was used as a working fluid. Channel width(CW) and height(CH) were selected as design factors. And thermal resistance, surface temperature of CPU, degree of superheat, and pressure drop were taken as objective responses. Fractional factorial DOE was used in screening phase and RSM(Response Surface Method) was used in optimization phase. As a result, CW of 2.5mm, CH of 2.5mm, and CL of 484mm were taken as an optimum geometry. Surface temperature of CPU and thermal resistance were $33^{\circ}C\;and\;0.0502^{\circ}C/W$ respectively. Thermal resistance of evaporator designed in this study was significantly lower than that of other cooling systems such as water cooling system and thermosyphon system. It was found that the evaporator considered in this work can be a excellent candidate for a high heat flux CPU cooling system.

정적연소실내의 디젤분무증발과 연소특성에 관한 연구 (A Study on the Diesel Spray Evaporation and Combustion Characteristics in Constant Volume Chamber)

  • 김상호;김석준;이만복;김응서
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.102-109
    • /
    • 1994
  • As a fundamental study to apply high pressure injection system to direct injection diesel engine, fuel injection system and constant volume combustion chamber were made and the behaviors of evaporating spray with the variation of injection pressure and the ambient gas temperature were observed by using high speed camera, and the combusion characteristics with the variation of injection pressure and A/F ratio were analyzed. As injection pressure increases, spray tip penetration and spray angle increase and, as a results spray volume increases. This helps an uniform mixing of fuel and air. Spray liquid core length decreases as ambient gas temperature increases, while it decreases as injection pressure increases but the effect of ambient gas temperature is dorminant. As injection pressure increases, ignition delay is shortened and combustion rate being raised, maximum heat release rate increases. It become clear that High injection pressure has high level of potential to improve the performance of DI-diesel engine.

  • PDF