• Title/Summary/Keyword: Evaluation parameter

Search Result 1,648, Processing Time 0.04 seconds

Evaluation of multi-objective PSO algorithm for SWAT auto-calibration (다목적 PSO 알고리즘을 활용한 SWAT의 자동보정 적용성 평가)

  • Jang, Won Jin;Lee, Yong Gwan;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.9
    • /
    • pp.803-812
    • /
    • 2018
  • The purpose of this study is to develop Particle Swarm Optimization (PSO) automatic calibration algorithm with multi-objective functions by Python, and to evaluate the applicability by applying the algorithm to the Soil and Water Assessment Tool (SWAT) watershed modeling. The study area is the upstream watershed of Gongdo observation station of Anseongcheon watershed ($364.8km^2$) and the daily observed streamflow data from 2000 to 2015 were used. The PSO automatic algorithm calibrated SWAT streamflow by coefficient of determination ($R^2$), root mean square error (RMSE), Nash-Sutcliffe efficiency ($NSE_Q$), and especially including $NSE_{INQ}$ (Inverse Q) for lateral, base flow calibration. The results between automatic and manual calibration showed $R^2$ of 0.64 and 0.55, RMSE of 0.59 and 0.58, $NSE_Q$ of 0.78 and 0.75, and $NSE_{INQ}$ of 0.45 and 0.09, respectively. The PSO automatic calibration algorithm showed an improvement especially the streamflow recession phase and remedied the limitation of manual calibration by including new parameter (RCHRG_DP) and considering parameters range.

Evaluation on the External Restraint Stress in Mass Concrete (매스콘크리트의 외부구속응력에 관한 검토)

  • 강석화;정한중;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.5
    • /
    • pp.111-122
    • /
    • 1996
  • The effects of external restraint on the thermal stresses i n mass concrete are investigated through a series of parametric study. Two major factors affecting the degree of external restraint such as the ratio of length to height of the placed structure (L/H) and the elastic modulus of base structure ($E_r$) are employed as the parameters in a condition which a placing height H is 1.0m. Various conditions of I,/H and E, are analysed by a FEM program and the relationship between these two parameters is examined. The shape of stress distribution due to the external restraint is shown as linearity on the height direction of the section, and is influenced by L/H, $E_r$, and strength development of placed concrete. The external restraint can be devided by two part. One is an axial restraint and the other is a flexural restraint. When the level of external restraint is low, the structure behavior is mainly governed by flexural restraint, otherwise it is dependent on axial restraint. Comparing the calculated stress by the method of the ACI 207 committee with a finite element analysis, the fbrmer overestimates the external restraint stress when the degree of external restraint is weak, and underestimates when it is strong.

Optimal HPLC Condition for Simultaneous Determination of Anthocyanins in Black Soybean Seed Coats (검정콩 함유 안토시아닌의 동시분석을 위한 최적 HPLC 분석 조건)

  • Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.4
    • /
    • pp.359-368
    • /
    • 2008
  • Black soybean has been widely utilized as foods and oriental medicinal materials. The pigmentation in the seed coat of black soybean is due to accumulate anthocyanins in the epidermis palisade layer. The anthocyanins of black soybean seed coat are considered as a parameter of quality evaluation of black soybean. Therefore, the purpose of this study was to investigate the most suitable HPLC condition for simultaneous determination of anthocyanins in black soybean seed coats extracts. The efficient HPLC analytical condition of D3G, C3G, and Pt3G contained extracts of black soybean seed coats was developed. The gradient elution employed a $250\;mm\;{\times}\;4.6\;mm$ i.d. YMC-pak ODS-AM 303 column. The gradient system was used two mobile phases. A gradient elution was performed with mobile phase A, consisting of 5% aqueous formic acid, and mobile phase B, comprising 5% formic acid - acetonitrile, and delivered at a flow rate of 0.7 mL/min as follows: $0{\sim}35\;min$, $90%\;A{\sim}60%\;A$; 36 min, 90% A; 46 min, 90% A. The UV-VIS. detection wavelength was set at 520 nm. The limit of detection (LOD) for D3G, C3G, and Pt3G were under 10 ng/mL.

Analysis Technique for Chloride Penetration using Double-layer and Time-Dependent Chloride Diffusion in Concrete (콘크리트내의 이중구조와 시간의존성을 고려한 염화물 해석기법의 개발)

  • Mun, Jin-Man;Kim, Jin-Yeong;Kim, Young-Joon;Oh, Gyeong-Seok;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.83-91
    • /
    • 2015
  • With varying conditions of concrete surface, induced chloride contents are changed and this is a key parameter for steel corrosion and service life in RC (Reinforced Concrete) structures. Many surface enhancement techniques using impregnation have been developed, however the evaluation techniques for chloride behavior through doubly layered media and time-dependent diffusion are rarely proposed. This paper presents an analysis technique considering double-layer concrete and time-dependent diffusion behavior, and the results are compared with those from the previous test results through reverse analysis. The chloride profiles from the surface-impregnated concrete exposed to atmospheric, tidal, submerged zone for 2 years are adopted. Furthermore surface chloride contents and diffusion coefficients are obtained, and are compared with those from Life365. Through consideration of time effect, the relative error decreases from 0.28 to 0.20 in atmospheric, 0.29 to 0.11 in tidal, and 0.54 to 0.40 in submerged zone, respectively, which shows more reasonable results. Utilizing the diffusion coefficients from Life365, relative errors increases and it needs deeper penetration depth (e) and lower diffusion coefficient ratio ($D_1/D_2$) due to higher diffusion coefficient.

Evaluation on Noise Characteristics by Field Application of Improved Rumble Strip (개선된 럼블스트립의 현장적용에 따른 사후 소음특성 평가)

  • An, Deok-Soon;Suh, Young-Chan;Son, Hyeon-Jang;Lee, Jae-Jun;Eom, Byeong-Sik
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.33-39
    • /
    • 2013
  • PURPOSES : This research investigates traffic noise characteristics as change the transverse rumble strips shape from rectangular to cylinder at toll plaza of highway. METHODS : The traffic noise was investigated at two different places at toll plaza of highway. One is modified grooving, another is employed cylinder shape of TRS instead of rectangular shape of TRS. A measurement of traffic noise was conducted at same location and time period. The traffic volume information was gotten from office of highway office and vehicle speed was measured by speed measuring device. The traffic noise measurement was conducted from 13:00 to 23:00 and by pass-by method. Also, the traffic noise was measured behind noise barrier. Various distance from noise barrier(7.5m, 30m, 50m) and different heights(1.2m, 3m, and 5m) were parameter for measurement of traffic noise in this study. RESULTS : The class 1 vehicle was contributed from traffic volume which was increased 1,500. However, the distribution of traffic speed didn't change compare to previous investigated period. From this study, It was found that the external traffic noise was changed as function of geometric shape of TRS. The external noise from modified grooving was less than 1.2dB(A) of the current TRS. A difference of traffic noise was 20dB(A) before and after barrier. It came from a noise barrier effect as reduction of traffic noise. According to investigate a traffic noise distribution near barrier, there is similar noise characteristic as function of height at 7.5m distance from noise barrier. Also, There is no different traffic noise between 30m and 50m from source of the noise of sound barrier. CONCLUSIONS : Based on this traffic noise investigation result, there is a clear characteristic difference as changed TRS shape. The traffic noise was reduced by changed TRS shape. Specially, traffic noise was decreased although the traffic volume was increase for same investigation time and period. It is implied that cylinder type of TRS significantly reduces the traffic noise. The specification of various TRS will be studied in the future.

Parameter Decision of Muskingum Channel Routing Method Based on the Linear System Assumption (선형시스템가정에 근거한 Muskingum 하도추적방법의 매개변수 결정)

  • Yoo, Chulsang;Sin, Jiye;Jun, Chang Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.5
    • /
    • pp.449-463
    • /
    • 2013
  • This study proposes the method for determining the Muskingum channel routing model parameters based on the assumption of linear system. The proposed method was applied to the Chungju dam basin for the evaluation. Additionally, the rainfall-runoff was repeated for the Yeongchun-Chungju dam reach using seven rainfall events observed. Summarizing the results is as follows. First, the concentration time and storage coefficient of a channel reach formed by the subdivision can be expressed as the difference between the concentration times and storage coefficients of upstream and downstream basins. The storage coefficients of the channel reach estimated is equal to the storage coefficient of the Muskingum channel routing model and the weight factor can be simply estimated using the ratio between the concentration time and storage coefficient. Second, the weight factor of the Muskingum model is in inverse proportion to the Russel coefficient, which is in between 0.4166 and 0.625 when considering the Russel coefficients generally applied. Finally the application to the Yeongchun-Chungju dam reach showed that the proposed method is still valid regardless of the limitations such as the uncertainty of the observed data.

Evaluation of Drought Events Using the Rectangular Pulses Poisson Process Model (구형펄스모형을 이용한 가뭄사상의 평가)

  • Yoo, Chul-Sang;Kim, Dae-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.4 s.165
    • /
    • pp.373-382
    • /
    • 2006
  • In this study a theoretical drought severity-duration-frequency analysis is performed based on a simple Rectangular Pulses Poisson Process Model(RPPM). Data set with various durations are prepared for a given truncation level, whose statistics are then derived to be used for parameter estimation. These parameters are then used for the theoretical drought severity-duration-frequency analysis. The analysis is considered for two cases; one is to consider the overlap probability and the other is not. The drought severity of considering the overlap probability increases more as the return period increases. However, the overlap probability itself decreases as the duration increases, which is because the occurrence probability of events decreases as the duration increases. Also, if the duration increases, the events rarely or even not occur, since parameters of the model cannot be estimated in those cases, so the drought severity may not be computed. This is an obvious limitation of the simple RPPM. In this study the return periods of the important drought events occurred in Seoul are estimated using the results of the study. If the return period of an event is assumed to be the longest one among those with various durations, the return periods of some important event in Seoul are estimated to be between 14 and 35 years. These return periods are not so long to indicate that these droughts can occur frequently.

Evaluation of the Clark Unit Hydrograph Parameters Depending on Basin and Meteorological Condition: 2. Estimation of Parameter Variability (유역 및 기상상태를 고려한 Clark 단위도의 매개변수 평가: 2. 매개변수의 변동성 추정)

  • Yoo, Chul-Sang;Lee, Ji-Ho;Kim, Kee-Wook
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.171-182
    • /
    • 2007
  • In this study, as a method for decreasing the confidence interval of the estimates of Clark hydrograph's concentration time and storage coefficient, regression equations of these parameters with respect to those of rainfall, meteorology, and basin characteristics are derived and analyzed using the Monte Carlo simulation technique. The results are also reviewed by comparing them with those derived by applying the Bootstrap technique and empirical equations. Results derived from this research are summarized as follows. (1) Even in case of limited rainfall events are available, it is possible to estimate the mean runoff characteristics by considering the affecting factors to runoff characteristics. (2) It is also possible to use the Monte Carlo simulation technique for estimating and evaluating the confidence intervals for concentration time and storage coefficient. The confidence intervals estimated in this study were found much narrower than those of Yoo et al. (2006). (3) A supporting result could also be derived using the Bootstrap technique. However, at least 20 independent rainfall events are necessary to get a rather significant result for concentration time and storage coefficient. (4) No empirical equations are found to be properly applicable for the study basin. However, empirical equations like the Kraven(I) and Kraven(II) are found valid for the estimation of concentration time, on the other hand the Linsley is found valid for the storage coefficient In this study basin. But users of these empirical formula should be careful as these also provide a wide range of possible values.

Microstructure, Tensile Strength and Probabilistic Fatigue Life Evaluation of Gray Cast Iron (회주철의 미세구조와 인장거동 분석 및 확률론적 피로수명평가)

  • Sung, Yong Hyeon;Han, Seung-Wook;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.721-728
    • /
    • 2017
  • High-grade gray cast iron (HCI350) was prepared by adding Cr, Mo and Cu to the gray cast iron (GC300). Their microstructure, mechanical properties and fatigue strength were studied. Cast iron was made from round bar and plate-type castings, and was cut and polished to measure the percentage of each microstructure. The size of flake graphite decreased due to additives, while the structure of high density pearlite increased in volume percentage improving the tensile strength and fatigue strength. Based on the fatigue life data obtained from the fatigue test results, the probability - stress - life (P-S-N) curve was calculated using the 2-parameter Weibull distribution to which the maximum likelihood method was applied. The P-S-N curve showed that the fatigue strength of HCI350 was significantly improved and the dispersion of life data was lower than that of GC300. However, the fatigue life according to fatigue stress alleviation increased further. Data for reliability life design was presented by quantitatively showing the allowable stress value for the required life cycle number using the calculated P-S-N curve.

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.